Free English DEYE SUN-25K-G02-LV (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD DEYE SUN-25K-G02-LV (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What do the safety signs on the DEYE SUN-25K-G02-LV indicate?
The following safety symbols are used to highlight potential risks and important information for the DEYE SUN-25K-G02-LV:
Warning: Indicates important safety instructions which, if not correctly followed, could result in serious injury or death.
Shock Hazard: Indicates important safety instructions which, if not correctly followed, could result in electric shock.
Safety Hint: Indicates important safety instructions which, if not correctly followed, could result in damage to or destruction of the inverter.
High Temperature Hazard: Indicates safety instructions regarding hot surfaces which, if not correctly followed, could result in burns.
What are the safety requirements for using the DEYE SUN-25K-G02-LV?
Operational requirements for the DEYE SUN-25K-G02-LV include:
1. The inverter should be installed and maintained by a qualified person under local standard regulations.
2. You must disconnect the AC side first, then disconnect the DC side during installation and maintenance. After that, wait at least 5 minutes to avoid getting shocked as the inverter discharges remnant electricity.
3. The local temperature of the inverter may exceed 80 degrees Celsius while operating. Do not touch the case to avoid injury.
4. All electrical installation must be in accordance with local electrical standards and achieve permission from the local power company.
5. Appropriate anti-static measures should be taken.
6. Install the unit where children cannot touch it.
7. Prohibit grounding the positive and negative poles of the PV string as it will damage the inverter.
How do I interpret the status indicator lights on the DEYE SUN-25K-G02-LV?
The DEYE SUN-25K-G02-LV features four indicators on the front panel display:
| Indicator | Status | Explanation |
| DC | on | Inverter detects DC input |
| DC | off | Low DC input voltage |
| AC | on | Grid Connected |
| AC | off | Grid Unavailable |
| NORMAL | on | Under normal operating |
| NORMAL | off | Stop operating |
| ALARM | on | Detected faults or report faults |
| ALARM | off | Under normal operating |
What are the functions of the buttons on the DEYE SUN-25K-G02-LV?
There are four buttons on the DEYE SUN-25K-G02-LV panel:
UP button: Used for page turning (up) and increasing parameters.
DOWN button: Used for page turning (down) and decreasing parameters.
ESC button: Used to exit or modify adjustable parameters.
ENTER button: Used to confirm selection or modify adjustable parameters.
What criteria should be considered when selecting an installation location for the DEYE SUN-25K-G02-LV?
To ensure proper operation of the DEYE SUN-25K-G02-LV, consider the following criteria:
1. Risk of fire: Do not install in areas containing highly flammable materials or gases or in potentially explosive atmospheres.
2. Ventilation: Do not install in small closed spaces where air cannot circulate freely. Blocked airflow can cause overheating.
3. Exposure: Avoid direct sunlight or rain. Exposure to direct sunlight increases the operational temperature and may cause output power limiting. Use a sunshade if the ambient air temperature exceeds 40 degrees Celsius.
4. Support: Install on a wall or strong structure capable of bearing the weight.
5. Orientation: Install vertically with a maximum incline of +/-15 degrees. Tiling beyond this can inhibit heat dissipation.
6. Clearance: If installing more than one inverter, leave at least a 500mm gap between each unit, and at least 500mm above and below.
What are the DC cable specifications for the DEYE SUN-25K-G02-LV?
| Cable type | Cross section Range (mm2) | Recommended value (mm2) |
| Industry generic PV cable (model: PV1-F) | 4.0 to 6.0 (12 to 10AWG) | 4.0 (12AWG) |
Before connecting, ensure the PV array open circuit voltage is within 1000V of the inverter and that the polarity matches the DC+ and DC- symbols.
How do I assemble the DC connectors for the DEYE SUN-25K-G02-LV?
Follow these steps to assemble the DC connectors:
1. Strip off the DC wire about 7mm and disassemble the connector cap nut.
2. Crimp the metal terminals with crimping pliers to the wire.
3. Insert the contact pin into the top part of the connector and screw up the cap nut.
4. Finally, insert the DC connector into the positive and negative inputs of the inverter.
What are the recommended current protector specifications for the DEYE SUN-25K-G02-LV?
| Inverter Model | Rated voltage (V) | Rated output power (KW) | Current protection device (A) |
| DEYE SUN-25K-G02-LV | 400 | 25 | (Not listed in Table 5.3, but SUN-30K is 60A and SUN-20K is 20KW rated. Based on technical data on page 51, SUN-25K uses a 65.6A Rated AC Grid Output Current) |
Note: For the DEYE SUN-25K-G02-LV specifically, the specifications from the general technical table indicate a rated output power of 25kW and a rated AC grid output current of 65.6A.
What is the procedure to start up the DEYE SUN-25K-G02-LV?
To start the inverter, follow these steps:
1. First, switch on the AC breaker.
2. Turn on the DC switch of the PV module. If the panel provides sufficient starting voltage and power, the inverter will start.
3. The inverter will check internal and grid parameters while the screen shows “self-checking”.
4. If parameters are within acceptable range, the inverter will generate energy and the NORMAL indicator light will turn on.
How do I safely shut off the DEYE SUN-25K-G02-LV?
Follow these steps to shut down the inverter:
1. Switch off the AC breaker.
2. Wait for 30 seconds, then turn off the DC switch or disconnect the DC input connector.
3. The inverter will close the LCD and all LEDs within two minutes.
What is the zero export function on the DEYE SUN-25K-G02-LV?
The DEYE SUN-25K-G02-LV has an optional external zero export function using a SUN limiter or energy meter. It collects counter-current power to control the output power of the inverter so that inverter power and load are offset, ensuring excess power is not fed back to the grid. The limiter has two modes:
Minimum mode: The limiter controls the power according to the phase with the lowest power to ensure no reverse current occurs in any phase.
Average mode: The limiter controls the output according to the average total power of the three-phase load, which may cause single phase backflow.
What are common error codes for the DEYE SUN-25K-G02-LV and how are they resolved?
| Error code | Description | Solution |
| F01 | DC input polarity reverse fault | Check the PV input polarity. |
| F02 | DC insulation impedance permanent fault | Check the grounding cable of inverter. |
| F04 | Ground fault GFDI | Check the solar panel output connection. |
| F05 | Read the memory error | Restart the inverter. If it persists, contact service. |
| F06 | Write the memory error | Restart the inverter. If it persists, contact service. |
| F10 | Auxiliary switch power supply failure | Check if DC 12V exists; restart the inverter. |
| F15 | AC firmware over current | Check if internal AC sensor or connection wire is loose. Restart inverter. |
| F16 | GFCI(RCD) AC leakage current fault | Leakage current over 300mA. Check DC power supply or panels; restart inverter. |
| F18 | AC over current fault of hardware | Check AC sensor or detection circuit on control board. Restart or factory reset. |
| F20 | DC over current fault of hardware | Check if solar panel output current is within range; check DC sensor. |
| F24 | DC insulation impedance failure | Check Vpe resistance or control board. Ensure PV panel and inverter are grounded. |
| F30 | AC main contactor failure | Check relays and AC voltage of relays. |
| F35 | No AC grid | Check AC grid voltage and detection circuit. Check if AC connector is in good condition. |
| F55 | DC busbar voltage is too high | Check PV voltage. If it exceeds limits, reduce the number of solar panels in series. |
| F56 | DC busbar voltage is too low | Check PV voltage. Often happens in early morning. May need firmware update. |
| F64 | IGBT heat sink high temperature | Check temperature sensor and firmware. Restart the inverter. |
What are the technical specifications for the DEYE SUN-25K-G02-LV?
| Specification | Value for DEYE SUN-25K-G02-LV |
| Max. DC Power | 32.5 kW |
| Max. DC Input Voltage | 800 V |
| Start-up DC Input Voltage | 250 V |
| MPPT Operating Range | 200 to 700 V |
| Max. DC Input Current | 40+40+40 A |
| Number of MPPT/Strings per MPPT | 3/3 |
| Rated Output Power | 25 kW |
| Max. Active Power | 27.5 kW |
| Rated AC Grid Voltage | 127/220 V |
| Rated AC Grid Output Current | 65.6 A |
| Max. Efficiency | 98.7% |
| Operating Temperature | -25 to 65 degrees Celsius |
| Ingress Protection | IP65 |
| Weight | 44.5 kg |
| Size (W x H x D) | 647.5 x 537 x 303.5 mm |
How do I maintain the DEYE SUN-25K-G02-LV?
The DEYE SUN-25K-G02-LV does not need regular maintenance. However, debris or dust can affect the heat sink performance. Clean it with a soft brush. If the surface is very dirty, a wet cloth can be used to clean the LCD and LED lamp. Do not use solvents, abrasive materials, or corrosive materials for cleaning any parts of the inverter.
CLICK HERE TO DOWNLOAD DEYE SUN-25K-G02-LV (01) PDF DOCUMENT