What are the electrical specifications for the CRES COR R171SUA10?

The electrical specifications for the CRES COR R171SUA10 are as follows:

Model No. Volts Amps Hertz Phase NEMA
R171SUA10 120 7.3 60 1 5-15P

How do I install the CRES COR R171SUA10 cabinet?

To install the cabinet, follow these steps:

1. Remove all packing material from inside the cabinet.

2. INSTALL ALL ANGLES BEFORE UNIT IS TURNED ON.

3. Allow enough clearance around the cabinet for air flow.


How do I operate the CRES COR R171SUA10?

1. Plug cord into proper wall outlet.

2. Turn the power switch to “ON”. The light will come on and the compressor will start. Listen closely for the compressor. It will be slightly loud at first, then quiet down. If you do not hear the compressor running, turn the power switch to “OFF” right away and see the “Troubleshooting” section.

3. Pre-chill the cabinet for approximately 40 minutes or until the temperature reaches approximately 38°F. Load the food.

DO NOT PUT HOT FOOD INTO COLD CABINET!


How do I shut off the CRES COR R171SUA10?

To shut the unit off, turn the power switch to “OFF”.


How do I reverse the door hardware for the opposite hand on my CRES COR R171SUA10?

This procedure is for single door cabinets only.

1. Remove hinge covers with a screwdriver.

2. Open door and lift up to remove door from cabinet.

3. Unscrew and re-mount the hinges and latch strike to the opposite sides of the cabinet.

4. Remove the door hinges and the door latch. Turn hinges and handle over and remount in the same holes.

5. Remove plastic cam from each hinge, rotate cam 180° with “V” groove on cam toward inside of cabinet. Reseat cam into hinge.

6. Plug all the extra holes with screws.

7. Put door onto cabinet and adjust as necessary.

8. Snap on hinge covers.


What are the safety precautions for cleaning the CRES COR R171SUA10?

Before cleaning the cabinet, please observe the following warnings:

1. Unplug cord from wall.

2. Do NOT hose cabinet with water.

3. Do NOT get water into bottom compartment.

4. Do NOT use abrasives or harsh chemicals.


What are the cleaning instructions and tips for the CRES COR R171SUA10?

Wipe up spills as soon as possible and clean regularly to avoid heavy dirt build-up.

Cleaning Hints:

1. Use the mildest cleaning procedure that will do the job.

2. Always rub in the direction of polish lines to avoid scratching the surface.

3. Use only a soft cloth, sponge, fibrous brushes, plastic or stainless steel pads for cleaning and scouring.

4. Rinse thoroughly with fresh water after every cleaning operation.

5. Always wipe dry to avoid water marks.


How do I clean different types of soil from my CRES COR R171SUA10?

The following table provides guidance for cleaning the stainless steel cabinet:

Soil Cleaner Method
ROUTINE CLEANING Soap, Ammonia, or mild *detergent and water. 1. Sponge on with cloth.
2. Rinse with water.
3. Wipe dry.
STUBBORN SPOTS AND STAINS Mild abrasive made for stainless steel. 1. Apply with damp sponge or cloth.
2. Rub lightly.
GREASE, OIL Chemical oven cleaner for stainless steel. Follow oven cleaner manufacturer’s directions.
HARD WATER SPOTS & SCALE Vinegar 1. Swab or wipe with cloth.
2. Rinse and dry.

*Mild detergents include soaps and non-abrasive cleaners.


What are the service specifications for the refrigeration system on the CRES COR R171SUA10?

The refrigerator is shipped fully charged. The specifications for charging and service are:

High-side pressure should be approximately 440 PSI.

Low pressure should be approximately 162 PSI at 75° F (24° C) room temperature.

The charge should be 18 ounces of R134a.

Service valves are located on the condenser/compressor assembly.


What should I do if the power light is off on my CRES COR R171SUA10?

If the power light is off when the unit is plugged in and the switch is ON, the probable cause is the Power Cord. Check that it is properly plugged in.


What should I do if the compressor is off on my CRES COR R171SUA10?

If the compressor is off when the unit is plugged in and the switch is ON, the probable cause is that the power supply is down. Check your circuit breaker or fuse box.


What are the possible causes if the evaporator fan and power light are on, but the compressor is off on my CRES COR R171SUA10?

If the evaporator fan and power light are on but the compressor is off, the probable causes are:

3a. Thermostat defective

3b. Defective start relay (compressor)


What should I do if the compressor is on but the CRES COR R171SUA10 cabinet is not cooling?

If the compressor is on but the cabinet is not cooling, check for the following probable causes:

4a. Low charge

4b. Frost build-up on evaporator coil

4c. Evaporator fan defective

4d. Thermostat defective


What could be the issue if the compressor on my CRES COR R171SUA10 starts and stops, and the cabinet is not cooling?

If the compressor starts and stops but the cabinet does not cool, the probable causes are:

5a. Low Charge

5b. Faulty start capacitor (compressor)

5c. Faulty start relay (compressor)


What should I check if the compressor on my CRES COR R171SUA10 is noisy?

If the compressor is noisy, the probable causes are:

6a. Low charge

6b. Defective


Can I adjust the thermostat on my CRES COR R171SUA10?

The thermostat is pre-set at approximately 38°F (3.8°C). Temperature adjustment can only be made by a Service Agency.


What are the replacement part numbers for the 120V CRES COR R171SUA10?

Description 120V Part Number
Condenser/Compressor Assembly 0854-040
Cord Set 0810-029-05
Door Assembly 1221-553-K
Evaporator Assembly for R171SUA10, 1828 1416-068-K
Gasket Kit 0861-261
Hinge Kit 0519-087-K
Pilot Light “Power ON” 0766-094
Post 0696-237
Rack Insert (1828, 1856) 1103-106
Receptacle 0713-057
Switch, ON/OFF 0808-116
Terminal Block 0852-091
Thermometer Kit 5238-035-K
Thermostat (cold control) 0854-043-K
Universal Angles (R171SUA10, R171SUA20) 0621-281-K
Valve, Thermal Exp. (R171SUA10, 1828) 0854-042-K1

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD CRES COR R171SUA10 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.