Free English CRES COR R171S1856240 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD CRES COR R171S1856240 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the electrical specifications for the CRES COR R171S1856240 series?
| Model No. | Volts | Amps | Hertz | Phase | NEMA |
|---|---|---|---|---|---|
| R171SUA10 R171S1828 |
120 | 7.3 | 60 | 1 | 5-15P |
| R171SUA10240 R171S1828240 |
240 | 3.7 | 60 | 1 | 6-15P |
| R171SUA20 R171S1856 |
120 | 8.0 | 60 | 1 | 5-15P |
| R171SUA20240 R171S1856240 |
240 | 4.2 | 60 | 1 | 6-15P |
Note: The above model numbers are basic models. They may be followed by letters: M, L, D or ending with S, Z and/or CAN.
How do I install the CRES COR R171S1856240 cabinet?
1. Remove all packing material from inside the cabinet.
2. INSTALL ALL ANGLES BEFORE UNIT IS TURNED ON.
3. Allow enough clearance around the cabinet for air flow.
What are the operating instructions for the CRES COR R171S1856240?
1. Plug the cord into a proper wall outlet.
2. Turn the power switch to “ON”. The light will come on and the compressor will start. Listen closely for the compressor. It will be slightly loud at first, then quiet down. If you do not hear the compressor running, turn the power switch to “OFF” right away and see the “Troubleshooting” section.
3. Pre-chill the cabinet for approximately 40 minutes or until the temperature reaches approximately 38°F. Load the food.
DO NOT PUT HOT FOOD INTO COLD CABINET!
How do I shut off the CRES COR R171S1856240?
Turn the power switch to “OFF”.
How can I reverse the door hardware for the opposite hand on my single door CRES COR R171S1856240?
1. Remove hinge covers with a screwdriver.
2. Open the door and lift up to remove the door from the cabinet.
3. Unscrew and re-mount the hinges and latch strike to the opposite sides of the cabinet.
4. Remove the door hinges and the door latch. Turn hinges and handle over and remount in the same holes.
5. Remove the plastic cam from each hinge, rotate the cam 180° with the “V” groove on the cam toward the inside of the cabinet. Reseat the cam into the hinge.
6. Plug all the extra holes with screws.
7. Put the door onto the cabinet and adjust as necessary.
8. Snap on the hinge covers.
How should I clean my CRES COR R171S1856240?
WARNING: Before cleaning the cabinet:
1. Unplug the cord from the wall.
2. Do NOT hose the cabinet with water.
3. Do NOT get water into the bottom compartment.
4. Do NOT use abrasives or harsh chemicals.
Wipe up spills as soon as possible. Clean regularly to avoid heavy dirt build-up.
Cleaning Hints:
1. Use the mildest cleaning procedure that will do the job.
2. Always rub in the direction of polish lines to avoid scratching the surface.
3. Use only a soft cloth, sponge, fibrous brushes, plastic or stainless steel pads for cleaning and scouring.
4. Rinse thoroughly with fresh water after every cleaning operation.
5. Always wipe dry to avoid water marks.
| Soil | Cleaner | Method | |
|---|---|---|---|
| CABINET Inside and Outside (Stainless Steel) |
ROUTINE CLEANING | Soap, Ammonia, or mild *detergent and water. | 1. Sponge on with cloth. 2. Rinse with water. 3. Wipe dry. |
| STUBBORN SPOTS AND STAINS | Mild abrasive made for stainless steel. | 1. Apply with damp sponge or cloth. 2. Rub lightly. |
|
| GREASE, OIL | Chemical oven cleaner for stainless steel. | Follow oven cleaner manufacturer’s directions. | |
| HARD WATER SPOTS & SCALE | Vinegar | 1. Swab or wipe with cloth. 2. Rinse and dry. |
*Mild detergents include soaps and non-abrasive cleaners.
What are the specifications for charging the refrigeration system on the CRES COR R171S1856240?
Note: The refrigerator is shipped fully charged.
The high-side pressure should be approximately 440 PSI.
Low pressure should be approximately 162 PSI at 75° F (24° C) room temperature.
The charge should be 18 ounces of R134a.
Service valves are located on the condenser/compressor assembly.
What should I do if my CRES COR R171S1856240 is not working correctly?
First, ensure the unit is plugged in and the switch is ON. Refer to the guide below for potential issues and causes.
| Failure | Probable Cause |
|---|---|
| 1. Power light off | 1. Power Cord |
| 2. Compressor off | 2. Power supply down |
| 3. Evaporator fan on, Power light on and Compressor off | 3a. Thermostat defective 3b. Defective start relay (compressor) |
| 4. Compressor on and cabinet not cooling | 4a. Low charge 4b. Frost build-up on evaporator coil 4c. Evaporator fan defective 4d. Thermostat defective |
| 5. Compressor starts and stops; cabinet not cooling | 5a. Low Charge 5b. Faulty start capacitor (compressor) 5c. Faulty start relay (compressor) |
| 6. Noisy compressor | 6a. Low charge 6b. Defective |
NOTES:
1. The thermostat is pre-set at approximately 38°F (3.8°C). Temperature adjustment can only be made by a Service Agency.
2. For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400).
What are the replacement part numbers for the CRES COR R171S1856240?
| Description | 120V | 240V |
|---|---|---|
| Condenser/Compressor Assembly | 0854-040 | 0854-041 |
| Cord Set | 0810-029-05 | 0810-039-06 |
| Door Assembly | 1221-553-K | 1221-553-K |
| Evaporator Assembly for R171SUA10, 1828 | 1416-068-K | 1416-070-K |
| Evaporator Assembly for R171SUA20, 1856 | 1416-069-K | 1416-071-K |
| Gasket Kit | 0861-261 | 0861-261 |
| Hinge Kit | 0519-087-K | 0519-087-K |
| Pilot Light “Power ON” | 0766-094 | 0766-095 |
| Post | 0696-237 | 0696-237 |
| Rack Insert (1828, 1856) | 1103-106 | 1103-106 |
| Receptacle | 0713-057 | 0713-058 |
| Switch, ON/OFF | 0808-116 | 0808-116 |
| Terminal Block | 0852-091 | 0852-091 |
| Thermometer Kit | 5238-035-K | 5238-035-K |
| Thermostat (cold control) | 0854-043-K | 0854-043-K |
| Universal Angles (R171SUA10, R171SUA20) | 0621-281-K | 0621-281-K |
| Valve, Thermal Exp. (R171SUA10, 1828) | 0854-042-K1 | 0854-042-K1 |
| Valve, Thermal Exp. (R171SUA20, 1856) | 0854-042-K2 | 0854-042-K2 |
| Vent Fan (R171SUA20, 1856 ONLY) | 0769-045-K | 0769-029-K |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD CRES COR R171S1856240 (01) PDF DOCUMENT
