What should I do to reduce the risk of electric shock on my BEHRINGER INUKE NU3000DSP?
To reduce the risk of electric shock on your BEHRINGER INUKE NU3000DSP, do not remove the top cover or the rear section, as there are no user serviceable parts inside. Refer servicing to qualified personnel.
What should I do to reduce the risk of fire or electric shock on my BEHRINGER INUKE NU3000DSP?
To reduce the risk of fire or electric shock on your BEHRINGER INUKE NU3000DSP, do not expose this appliance to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids, and no objects filled with liquids, such as vases, shall be placed on the apparatus.
What are the service instructions for my BEHRINGER INUKE NU3000DSP for qualified service personnel?
These service instructions for the BEHRINGER INUKE NU3000DSP are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by qualified service personnel.
What are the basic steps to follow when operating my BEHRINGER INUKE NU3000DSP?
The basic steps to follow when operating your BEHRINGER INUKE NU3000DSP are:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
How do I handle the polarized or grounding-type plug on my BEHRINGER INUKE NU3000DSP to ensure safety?
Do not defeat the safety purpose of the polarized or grounding-type plug on your BEHRINGER INUKE NU3000DSP. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
How should the power cord be positioned for my BEHRINGER INUKE NU3000DSP?
Protect the power cord of your BEHRINGER INUKE NU3000DSP from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
What kind of attachments/accessories should be used with my BEHRINGER INUKE NU3000DSP?
Use only attachments/accessories specified by the manufacturer for your BEHRINGER INUKE NU3000DSP.
What cart, stand, tripod, bracket, or table should be used with my BEHRINGER INUKE NU3000DSP?
Use only the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus for your BEHRINGER INUKE NU3000DSP. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
When should I unplug my BEHRINGER INUKE NU3000DSP?
Unplug your BEHRINGER INUKE NU3000DSP apparatus during lightning storms or when unused for long periods of time.
When is servicing required for my BEHRINGER INUKE NU3000DSP?
Servicing of your BEHRINGER INUKE NU3000DSP is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Refer all servicing to qualified service personnel.
How should the BEHRINGER INUKE NU3000DSP be connected to the mains socket outlet?
The BEHRINGER INUKE NU3000DSP apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
How should the disconnect device function for the BEHRINGER INUKE NU3000DSP?
Where the MAINS plug or an appliance coupler is used as the disconnect device for the BEHRINGER INUKE NU3000DSP, the disconnect device shall remain readily operable.
How do I turn on the power for the BEHRINGER INUKE NU3000DSP?
Power on the BEHRINGER INUKE NU3000DSP amplifier by pressing the POWER button. The startup screen will appear on the LCD display.
How do I step through DSP screens on the BEHRINGER INUKE NU3000DSP?
Press the PROCESS button on the BEHRINGER INUKE NU3000DSP to move step through DSP screens.
How do I toggle between Graphic Mode and Edit Mode on the BEHRINGER INUKE NU3000DSP within each screen?
Within each screen on the BEHRINGER INUKE NU3000DSP, push the SELECT encoder knob to toggle between Graphic Mode and Edit Mode.
How do I change parameters on the BEHRINGER INUKE NU3000DSP in Edit Mode?
In Edit Mode on the BEHRINGER INUKE NU3000DSP, turn the SELECT encoder knob to change parameters. Press the UP/DOWN/EXIT buttons to step through values and channels.
How do I choose the signal path on the I/O (Amp Mode) screen of the BEHRINGER INUKE NU3000DSP?
On the I/O (Amp Mode) screen of the BEHRINGER INUKE NU3000DSP, choose your signal path: BRIDGE, DUAL (Dual Mono), STEREO, BIAMP1 or BIAMP2.
How do I deploy parametric equalizer filters on the PEQ screen of the BEHRINGER INUKE NU3000DSP?
On the PEQ screen of the BEHRINGER INUKE NU3000DSP, deploy up to 8 different parametric equalizer filters to shape your sound.
How do I configure crossover points on the XOVER screen of the BEHRINGER INUKE NU3000DSP?
On the XOVER screen of the BEHRINGER INUKE NU3000DSP, choose up to 2 cutoff frequency crossover points, and up to 10 different filter curves for each output.
How can I use Dynamic EQ modules on the DEQ screen of the BEHRINGER INUKE NU3000DSP?
On the DEQ screen of the BEHRINGER INUKE NU3000DSP, you may deploy Dynamic EQ modules (up to 2 per stereo channel) to monitor designated frequency ranges within your signal. You may program the Dynamic EQ filters (band-pass, high-pass, or lo-pass) to boost or cut the designated range of frequencies based on your preferred gain threshold, including programmable ratio (Ratio), attack (Atime), and release (Rtime) parameters.
How can I use the DELAY screens on the BEHRINGER INUKE NU3000DSP to compensate for phase cancellation?
On the DELAY screens of the BEHRINGER INUKE NU3000DSP, you may compensate for phase cancellation problems in your system by altering signal phase (PHASE: 0° or 180°) and/or delaying the signal output (Delay: 0 to 300 msec) from designated channels to match up with sound traveling over distance (e.g., compensating for sound traveling outward from the stage to sound reinforcement speakers placed out in the audience).
How do I save or load presets, lock the panel, set a password, and control the LCD contrast using the SETUP button on the BEHRINGER INUKE NU3000DSP?
Press the SETUP button on the BEHRINGER INUKE NU3000DSP to save or load presets, lock the panel and set a password, and control the LCD contrast.
How do I exit to the top-level iNUKE screen on the BEHRINGER INUKE NU3000DSP?
To exit to the top-level iNUKE screen on the BEHRINGER INUKE NU3000DSP, press the EXIT button.
How do I implement my own limiter settings on the Limit screen of the BEHRINGER INUKE NU3000DSP?
On the Limit screen of the BEHRINGER INUKE NU3000DSP, you may implement your own threshold (Thresh[old]), release (Rtime), and hold (Hold) settings using the built-in limiters.
What are the input and output specifications for the BEHRINGER INUKE NU3000DSP?
The specifications for the BEHRINGER INUKE NU3000DSP are as follows:
| Specification | NU3000DSP |
| Inputs | 2 x combo jacks (XLR balanced, 1/4″ TRS) |
| Input impedance | 10 kΩ unbalanced, 20 kΩ balanced |
| Outputs | 2 x locking-style professional speaker connectors |
What are the output power ratings for the BEHRINGER INUKE NU3000DSP?
The output power ratings for the BEHRINGER INUKE NU3000DSP are:
| Mode | 4Ω | 8Ω |
| Stereo (4Ω per channel, stereo) | 820 W | 310 W |
| Stereo (2Ω per channel, stereo) | 1520 W | 530 W |
| Bridged mono (4Ω mode) | 1520 W | |
| Bridged mono (2Ω mode) | 3000 W |
What are the general controls and indicators on the front panel of the BEHRINGER INUKE NU3000DSP?
The front panel controls and indicators for the BEHRINGER INUKE NU3000DSP include:
Power switch, Gain controls (channels A and B), DSP section rotary push-encoder, Buttons for Process, Setup, Up/Down, Exit.
Indicators include Amber backlit illuminated gain controls for Power, Limit (per channel), and Signal (per channel).
What are the characteristics of the Digital Signal Processing (DSP) on the BEHRINGER INUKE NU3000DSP?
The Digital Signal Processing (DSP) features for the BEHRINGER INUKE NU3000DSP include:
- Display: LCD 128 x 32, amber backlit
- Digital delay function (per channel): 0-300 ms
- Digital crossover function: 3 filter types, up to 48 dB/octave
- Digital EQ function (per channel): 8-band parametric, 2-band dynamic equalizer
- Digital dynamics function (per channel): Zero attack limiter (peak)
- Presets: 20 total presets, 19 user-definable
What is the procedure for Bi-amping using the BEHRINGER INUKE NU3000DSP in BIAMP1 mode?
To perform Bi-amping using the BEHRINGER INUKE NU3000DSP in BIAMP1 mode:
1. Choose the BIAMP1 setting on the Amp Mode screen.
2. Run a 4-pole speaker cable with professional twist-locking connectors from OUTPUTS CH A to the subwoofer. (The subwoofer receives its low-frequency signal from Channel B using poles 2+ and 2-, while the middle and upper frequency ranges use Channel A via poles 1+ and 1-).
3. Set the subwoofer into BIAMPING mode.
4. Run a 2-pole speaker cable with professional twist-locking connectors from the subwoofer to the other speaker.
5. Go to the XOVER screen using the UP/DOWN buttons to set appropriate high/low crossover frequencies.
6. In Channel A#1, choose your high-pass filter type (HPtype: BUT6, BUT12, BES12, etc.) and set the cutoff frequency (HPfreq) to approximately 100 Hz. Deactivate the low-pass filter (LPtype: OFF) on this channel and set the gain level (Gain) to suit your system.
7. In Channel B#1, choose your low-pass filter type (LPtype: BUT6, BUT12, BES12, etc.) and set the cutoff frequency (LPfreq) to approximately 100 Hz. Deactivate the high-pass filter (HPtype: OFF) on this channel and set the gain level (Gain) to suit your system.
What are the power consumption specifications for the BEHRINGER INUKE NU3000DSP?
The power consumption specifications for the BEHRINGER INUKE NU3000DSP are:
| Condition | NU3000DSP |
| Power consumption @ 2 ohms | 620 W |
| Power consumption @ 4 ohms | 350 W |