Free English BEHRINGER INUKE NU6000DSP (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD BEHRINGER INUKE NU6000DSP (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What should I do to reduce the risk of electric shock when using the BEHRINGER INUKE NU6000DSP?
To reduce the risk of electric shock, do not remove the top cover or the rear section. Refer servicing to qualified personnel as there are no user serviceable parts inside.
What precaution should I take to reduce the risk of fire or electric shock for the BEHRINGER INUKE NU6000DSP?
To reduce the risk of fire or electric shock, do not expose this apparatus to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids, such as vases, shall be placed on the apparatus.
What should I do if the terminals on the BEHRINGER INUKE NU6000DSP are marked with a symbol indicating a risk of electric shock?
Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality professional speaker cables with 1/4″ TS or twist-locking plugs pre-installed. All other installation or modification should be performed only by qualified personnel.
What does the symbol, wherever it appears on the BEHRINGER INUKE NU6000DSP, alert me to?
This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure – voltage that may be sufficient to constitute a risk of shock.
What does the triangle symbol, wherever it appears on the BEHRINGER INUKE NU6000DSP literature, alert me to?
This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.
What service procedures are service instructions for the BEHRINGER INUKE NU6000DSP use by qualified personnel only?
These service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by qualified service personnel.
What are the general safety instructions to follow when using the BEHRINGER INUKE NU6000DSP?
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Use only attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
How do I power on the BEHRINGER INUKE NU6000DSP?
Power on the amplifier by pressing the POWER button. The startup screen will appear on the LCD display.
How do I move through the DSP screens on the BEHRINGER INUKE NU6000DSP?
Press the PROCESS button to move by step through DSP screens.
How do I toggle between Graphic Mode and Edit Mode on the BEHRINGER INUKE NU6000DSP within each screen?
Within each screen push the SELECT encoder knob to toggle between Graphic Mode and Edit Mode.
How do I choose the active channel and module number in Graphic Mode on the BEHRINGER INUKE NU6000DSP?
In Graphic Mode, turn the SELECT encoder knob to choose the active channel and module number (e.g., DEQ filters A#1 or A#2).
How do I change parameters in Edit Mode on the BEHRINGER INUKE NU6000DSP?
In Edit Mode, turn the SELECT encoder knob to change parameters. Press the UP/DOWN/EXIT buttons to step through values and channels.
How do I choose the signal path on the I/O (Amp Mode) screen of the BEHRINGER INUKE NU6000DSP?
On the I/O (Amp Mode) screen, choose your signal path: BRIDGE, DUAL (Dual Mono), STEREO, BIAMP1 or BIAMP2.
How do I shape my sound using the PEQ screen on the BEHRINGER INUKE NU6000DSP?
On the PEQ screen, deploy up to 8 different parametric equalizer filters to shape your sound.
How do I set up crossover points on the XOVER screen of the BEHRINGER INUKE NU6000DSP?
On the XOVER screen, choose up to 2 cutoff frequency crossover points, and up to 10 different filter curves for each output.
How can I use Dynamic EQ modules on the DEQ screen of the BEHRINGER INUKE NU6000DSP?
On the DEQ screen, you may deploy Dynamic EQ modules (up to 2 per stereo channel) to monitor designated frequency ranges within your signal. You may program the Dynamic EQ filters (band-pass, high-pass, or lo-pass) to boost or cut the designated range of frequencies based on your preferred gain threshold, including programmable ratio (Ratio), attack (Atime), and release (Rtime) parameters.
How can I use the DELAY screens on the BEHRINGER INUKE NU6000DSP to compensate for phase cancellation problems?
On the DELAY screens, you may compensate for phase cancellation problems in your system by altering signal phase (PHASE: 0° or 180°) and/or delaying the signal output (Delay: 0 to 300 msec) from designated channels to match up with sound traveling over distance (e.g., compensating for sound traveling outward from the stage to sound reinforcement speakers placed out in the audience).
How do I save or load presets, lock the panel, set a password, and control the LCD contrast on the BEHRINGER INUKE NU6000DSP?
Press the SETUP button to save or load presets, lock the panel and set a password, and control the LCD contrast.
How do I exit to the top-level iNUKE screen on the BEHRINGER INUKE NU6000DSP?
To exit to the top-level iNUKE screen, press the EXIT button.
How do I implement my own limiter settings using the Limit screen on the BEHRINGER INUKE NU6000DSP?
On the Limit screen, you may implement your own threshold (Thresh[old]), release (Rtime), and hold (Hold) settings using the built-in limiters.
What is the purpose of the USB connection on the BEHRINGER INUKE NU6000DSP?
USB connection enables firmware updates and control over parameters via computer. The USB port is for amplifier configuration only.
How do I adjust the input level using the CH A/CH B CONTROLS on the BEHRINGER INUKE NU6000DSP?
CH A/CH B CONTROLS adjust the input level. To increase signal gain, rotate the knobs clockwise; to reduce the gain, rotate the knobs counter-clockwise.
What is indicated by the SIGNAL and LIMIT LEDs on the BEHRINGER INUKE NU6000DSP?
SIGNAL and LIMIT LEDs display the signal level for each channel. Reduce the input gain if the red LIMIT LED lights up continuously.
How do I select BIAMPING mode on the subwoofer when setting up Bi-amping with the BEHRINGER INUKE NU6000DSP?
Set the subwoofer into BIAMPING mode.
How should I connect the subwoofer using a 4-pole speaker cable for Bi-amping with the BEHRINGER INUKE NU6000DSP?
Run a 4-pole speaker cable with professional twist-locking connectors from OUTPUTS CH A to the subwoofer. The subwoofer receives its low-frequency signal from Channel B using poles 2+ and 2-, while the middle and upper frequency ranges use Channel A via poles 1+ and 1-.
How should I set up the high-pass filter on Channel A#1 when Bi-amping with the BEHRINGER INUKE NU6000DSP?
In Channel A#1, choose your high-pass filter type (HPtype: BUT6, BUT12, BES12, etc.) and set the cutoff frequency (HPfreq) to approximately 100 Hz. Deactivate the low-pass filter (LPtype: OFF) on this channel and set the gain level (Gain) to suit your system.
How should I set up the low-pass filter on Channel B#1 when Bi-amping with the BEHRINGER INUKE NU6000DSP?
In Channel B#1, choose your low-pass filter type (LPtype: BUT6, BUT12, BES12, etc.) and set the cutoff frequency (LPfreq) to approximately 100 Hz. Deactivate the high-pass filter (HPtype: OFF) on this channel and set the gain level (Gain) to suit your system.
What are the specifications for Maximum Output Power for the BEHRINGER INUKE NU6000DSP?
| Configuration | NU6000DSP | NU3000DSP | NU1000DSP |
|---|---|---|---|
| Stereo 8Ω per channel, stereo | 1600 W | 440 W | 160 W |
| Stereo 4Ω per channel, stereo | 3100 W | 820 W | 310 W |
| Stereo 2Ω per channel, stereo | 1520 W | 530 W | |
| Bridged mono 8Ω | 3000 W | 1050 W |
What are the specifications for Distortion for the BEHRINGER INUKE NU6000DSP?
| Configuration | NU6000DSP | NU3000DSP | NU1000DSP |
|---|---|---|---|
| Class D <0.2% | Class D <0.3% | Class D <0.1% |
What are the specifications for Frequency response and Damping factor for the BEHRINGER INUKE NU6000DSP?
| Specification | NU6000DSP | NU3000DSP | NU1000DSP |
|---|---|---|---|
| Frequency response | 20 Hz to 20 kHz, +0/-2 dB | 20 Hz to 20 kHz, +0/-1 dB | 20 Hz to 20 kHz, +0/-1 dB |
| Damping factor | >140 @ 8 Ω | >145 @ 8 Ω | >155 @ 8 Ω |
What are the specifications for Signal-to-noise ratio for the BEHRINGER INUKE NU6000DSP?
| Specification | NU6000DSP | NU3000DSP | NU1000DSP |
|---|---|---|---|
| Signal-to-noise | >98 dB | >100 dB |
What are the specifications for Dimensions and Weight for the BEHRINGER INUKE NU6000DSP?
| Specification | NU6000DSP | NU3000DSP | NU1000DSP |
|---|---|---|---|
| Dimensions (H x W x D) | approx. 3.5 x 19 x 12.91″ / 89 x 483 x 328 mm | approx. 3.5 x 19 x 9.76″ / 89 x 483 x 248 mm | approx. 3.5 x 19 x 9.76″ / 89 x 483 x 248 mm |
| Weight | approx. 11.9 lbs/5.4 kg | approx. 6.8 lbs/3.1 kg | approx. 6.4 lbs/2.9 kg |
What type of connectors are used for inputs and outputs on the BEHRINGER INUKE NU6000DSP?
Inputs are 2 x combo jacks (XLR and balanced 1/4″ TRS) and Outputs are 2 x locking-style professional speaker connectors.
What is the input impedance for the BEHRINGER INUKE NU6000DSP?
The input impedance is 10 kΩ unbalanced and 20 kΩ balanced.
What are the features of the Digital Signal Processing (DSP) section on the BEHRINGER INUKE NU6000DSP?
The DSP section includes an LCD 128 x 32 display with amber backlit, a digital delay function (0-300 ms), a digital crossover function (3 filter types, up to 48 dB/octave), a digital EQ function (8-band parametric, 2-band dynamic equalizer), and a zero attack limiter (peak). There are 20 total presets, 19 of which are user-definable.
What is the purpose of the amber backlit illuminated gain controls on the BEHRINGER INUKE NU6000DSP?
The amber backlit illuminated gain controls indicate the signal level. For limit indication, the levels are -24, -12, and -6 dB for full scale.