What should I do to reduce the risk of electric shock for the BEHRINGER INUKE NU1000DSP?

To reduce the risk of electric shock for the BEHRINGER INUKE NU1000DSP, do not remove the top cover or the rear section. Refer servicing to qualified personnel as there are no user-serviceable parts inside.


How can I reduce the risk of fire or electric shock for the BEHRINGER INUKE NU1000DSP?

To reduce the risk of fire or electric shock for the BEHRINGER INUKE NU1000DSP, do not expose this apparatus to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids, such as vases, shall be placed on the apparatus.


What are the basic steps for safe operation of the BEHRINGER INUKE NU1000DSP?

The basic steps for safe operation of the BEHRINGER INUKE NU1000DSP include:

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.


How should the power cord be handled for the BEHRINGER INUKE NU1000DSP?

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.


What attachments/accessories should be used with the BEHRINGER INUKE NU1000DSP?

Use only attachments/accessories specified by the manufacturer with the BEHRINGER INUKE NU1000DSP.


What should be done with the BEHRINGER INUKE NU1000DSP during lightning storms or when unused for long periods of time?

Unplug this apparatus during lightning storms or when unused for long periods of time.


When is servicing required for the BEHRINGER INUKE NU1000DSP?

Servicing is required when the BEHRINGER INUKE NU1000DSP has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Refer all servicing to qualified service personnel.


How should the BEHRINGER INUKE NU1000DSP be connected to the power outlet?

The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.


How is the power turned on and off for the BEHRINGER INUKE NU1000DSP?

The POWER button turns the BEHRINGER INUKE NU1000DSP amplifier on and off.


How do the SIGNAL and LIMIT LEDs display on the BEHRINGER INUKE NU1000DSP?

The SIGNAL and LIMIT LEDs display the signal level for each channel. Reduce the input gain if the red LIMIT LED lights up continuously.


How do I adjust the input level using the CH A/CH B CONTROLS on the BEHRINGER INUKE NU1000DSP?

The CH A/CH B CONTROLS adjust the input level. To increase signal gain, rotate the knobs clockwise; to reduce the gain, rotate the knobs counter-clockwise.


How do I step through the DSP processing modules on the BEHRINGER INUKE NU1000DSP?

The PROCESS button steps through the DSP processing modules on the BEHRINGER INUKE NU1000DSP.


What is displayed on the LCD SCREEN of the BEHRINGER INUKE NU1000DSP?

The LCD SCREEN displays the current DSP module and parameter settings of the BEHRINGER INUKE NU1000DSP.


How can I step through parameters within the DSP processing modules on the BEHRINGER INUKE NU1000DSP?

The SETUP button steps through parameters within the DSP processing modules on the BEHRINGER INUKE NU1000DSP.


How can I navigate DSP modules and parameters or exit to the top-level iNUKE screen on the BEHRINGER INUKE NU1000DSP?

The UP/DOWN/EXIT buttons step through DSP modules and parameters or exit to the top-level iNUKE screen (center button) on the BEHRINGER INUKE NU1000DSP.


How can I toggle between Graphic and Edit modes or change parameter values on the BEHRINGER INUKE NU1000DSP?

The SELECT encoder knob toggles between Graphic and Edit modes (when pressed) and changes parameter values (when rotated) on the BEHRINGER INUKE NU1000DSP.


What is the purpose of the USB connection on the BEHRINGER INUKE NU1000DSP?

The USB connection on the BEHRINGER INUKE NU1000DSP enables firmware updates and control over parameters via computer. The USB port is for amplifier configuration only.


How do I power on the BEHRINGER INUKE NU1000DSP amplifier?

Power on the amplifier by pressing the POWER button. The startup screen will appear on the LCD display.


How do I move through DSP screens on the BEHRINGER INUKE NU1000DSP?

Press the PROCESS button to move by step through DSP screens on the BEHRINGER INUKE NU1000DSP.


How do I toggle between Graphic Mode and Edit Mode within each screen on the BEHRINGER INUKE NU1000DSP?

Within each screen push the SELECT encoder knob to toggle between Graphic Mode and Edit Mode on the BEHRINGER INUKE NU1000DSP.


How do I change parameters in Edit Mode on the BEHRINGER INUKE NU1000DSP?

In Edit Mode, turn the SELECT encoder knob to change parameters through values and channels. Press the UP/DOWN/EXIT buttons to step through values and channels.


How do I choose the signal path on the I/O (Amp Mode) screen of the BEHRINGER INUKE NU1000DSP?

On the I/O (Amp Mode) screen, choose your signal path: BRIDGE, DUAL (Dual Mono), STEREO, BIAMP1 or BIAMP2 on the BEHRINGER INUKE NU1000DSP.


How can I use parametric equalizer filters on the PEQ screen of the BEHRINGER INUKE NU1000DSP?

On the PEQ screen, deploy up to 8 different parametric equalizer filters to shape your sound on the BEHRINGER INUKE NU1000DSP.


How can I set up crossover points on the XOVER screen of the BEHRINGER INUKE NU1000DSP?

On the XOVER screen, choose up to 2 cutoff frequency crossover points, and up to 10 different filter curves for each output on the BEHRINGER INUKE NU1000DSP.


How can I use Dynamic EQ modules on the DEQ screen of the BEHRINGER INUKE NU1000DSP?

On the DEQ screen, you may deploy Dynamic EQ modules (up to 2 per stereo channel) to monitor designated frequency ranges within your signal on the BEHRINGER INUKE NU1000DSP. You may program the Dynamic EQ filters (band-pass, high-pass, or lo-pass) to boost or cut the designated range of frequencies based on your preferred gain threshold, including programmable ratio (Ratio), attack (Atime), and release (Rtime) parameters.


How can I use the DELAY screens on the BEHRINGER INUKE NU1000DSP to compensate for phase cancellation problems?

On the DELAY screens, you may compensate for phase cancellation problems in your system by altering signal phase (PHASE: 0° or 180°) and/or delaying the signal output (Delay: 0 to 300 msec) from designated channels to match up with sound traveling over distance (e.g., compensating for sound traveling outward from the stage to sound reinforcement speakers placed out in the audience) on the BEHRINGER INUKE NU1000DSP.


How do I save or load presets, lock the panel, and set a password on the BEHRINGER INUKE NU1000DSP?

Press the SETUP button to save or load presets, lock the panel and set a password, and control the LCD contrast on the BEHRINGER INUKE NU1000DSP.


How do I exit to the top-level iNUKE screen on the BEHRINGER INUKE NU1000DSP?

To exit to the top-level iNUKE screen, press the EXIT button on the BEHRINGER INUKE NU1000DSP.


What happens to recent changes on the BEHRINGER INUKE NU1000DSP after exiting to the main screen?

The iNUKE DSP automatically stores any recent changes after two minutes or after exiting to the main screen via the EXIT button. These saved changes will be available the next time you power on the unit.


How can I apply my own threshold, release, and hold settings using the limiters on the Limit screen of the BEHRINGER INUKE NU1000DSP?

On the Limit screen, you may implement your own threshold (Thresh[old]), release (Rtime), and hold (Hold) settings using the built-in limiters on the BEHRINGER INUKE NU1000DSP.


What is the procedure for Bi-amping the BEHRINGER INUKE NU1000DSP?

The steps for Bi-amping the BEHRINGER INUKE NU1000DSP are as follows:

1. Choose the BIAMP1 setting on the Amp Mode screen.

2. Run a 4-pole speaker cable with professional twist-locking connectors from OUTPUTS CH A to the subwoofer. (The subwoofer receives its low-frequency signal from Channel B using poles 2+ and 2-, while the middle and upper frequency ranges use Channel A via poles 1+ and 1-).

3. Set the subwoofer into BIAMPING mode.

4. Run a 2-pole speaker cable with professional twist-locking connectors from the subwoofer to the other speaker.

5. Go to the XOVER screen using the UP/DOWN buttons to set appropriate high/low crossover frequencies.

6. In Channel A#1, choose your high-pass filter type (HPtype: BUT6, BUT12, BES12, etc.) and set the cutoff frequency (HPfreq) to approximately 100 Hz. Deactivate the low-pass filter (LPtype: OFF) on this channel and set the gain level (Gain) to suit your system.

7. In Channel B#1, choose your low-pass filter type (LPtype: BUT6, BUT12, BES12, etc.) and set the cutoff frequency (LPfreq) to approximately 100 Hz. Deactivate the high-pass filter (HPtype: OFF) on this channel and set the gain level (Gain) to suit your system.


What are the specifications for Output Power for the BEHRINGER INUKE NU1000DSP?

The Output Power specifications for the BEHRINGER INUKE NU1000DSP are:

Mode @ 8Ω @ 4Ω @ 2Ω
Stereo 160 W 310 W 530 W
Bridged mono 620 W

What are the specifications for System Controls on the BEHRINGER INUKE NU1000DSP?

The System Controls specifications for the BEHRINGER INUKE NU1000DSP include:

Item Specification
Front Panel Power switch, Gain controls (channels A and B) DSP section rotary push-encoder, Buttons for Process, Setup, Up/Down, Exit
Indicators Amber backlit illuminated gain controls
Power 0 dB, full scale
Limit (per channel) -24, -12, -6 dB
Signal (per channel) 0 dB, full scale
Display LCD 128 x 32, amber backlit
Digital delay function (per channel) 0-300 ms
Digital crossover function 3 filter types, up to 48 dB/octave
Digital EQ function (per channel) 8-band parametric, 2-band dynamic equalizer
Digital dynamics function (per channel) Zero attack limiter (peak)
Presets 20 total presets, 19 user-definable

What are the specifications for Connectors, Distortion, Frequency Response, Damping Factor, and Signal-to-Noise on the BEHRINGER INUKE NU1000DSP?

The following specifications apply to the BEHRINGER INUKE NU1000DSP:

Item Specification
Inputs 2 x combo jacks
Input impedance 10 kΩ unbalanced, 20 kΩ balanced
Outputs 2 x locking-style professional speaker connectors
Output circuit type Class D
Distortion <0.1%
Frequency response 20 Hz to 20 kHz, +0/-1 dB
Damping factor >155 @ 8 Ω
Signal-to-noise >100 dB

What are the specifications for Power Supply, Power Consumption, Dimensions, and Weight for the BEHRINGER INUKE NU1000DSP when operating with the voltage configuration for Japan?

The specifications for the BEHRINGER INUKE NU1000DSP operating with the voltage configuration for Japan are:

Item Specification
Voltage 100 V~, 50/60 Hz (T 10 A H 250 V)
Power consumption @ 2 ohms 150 W
Power consumption @ 4 ohms 70 W
Mains connector Standard IEC receptacle
Dimensions (H x W x D) approx. 3.5 x 19 x 9.76″ / 89 x 483 x 248 mm
Weight approx. 6.4 lbs/2.9 kg