What are the important safety warnings for the ARCTIC WIND AP12018?
Please observe the following safety warnings when using your ARCTIC WIND AP12018:
1. The appliance is not intended for use by young children or infirm persons without supervision.
2. Young children should be supervised to ensure that they do not play with the appliance.
3. The plug must be accessible after the appliance is installed.
4. The appliance shall be installed in accordance with national wiring regulations.
5. The appliance cannot be installed in a laundry room.
6. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person to avoid a hazard.
7. Please wait three minutes before restarting after the power has been interrupted.
8. The appliance should be connected to a supply with a system impedance of Zsys=0.468 or less, in compliance with EN 61000-3-11:2000.
9. The minimum clearance from the appliance to any combustible surface is 1 meter.
Under what ambient temperature conditions is the ARCTIC WIND AP12018 recommended for use?
The ARCTIC WIND AP12018 and other air conditioning patterns are recommended when the ambient temperature is between 18°C (65°F) and 35°C (95°F). For temperatures below 18°C (65°F) or above 35°C (95°F), other air conditioning patterns are recommended, regardless of the connection mode.
What do the buttons and display on the control panel of the ARCTIC WIND AP12018 do?
The control panel allows you to manage all functions of your ARCTIC WIND AP12018. The layout may vary slightly by model.
1. REMOTE CONTROLLER SIGNAL RECEIVER: Receives signals from the remote control.
2. DIGITAL DISPLAY:
– In FAN mode, it shows the room temperature.
– In COOL or DRY mode, it shows the set temperature.
– When setting the timer, it displays the set time. After 5 seconds, it reverts to showing the temperature.
– If the room temperature sensor fails, it will display a temperature of 25°C (77°F).
3. TEMP (+/-) button:
– In normal operation, press to adjust the set temperature between 17°C (63°F) and 31°C (88°F).
– When the timer is being set (digital display flashing), press these buttons to set the timer between 1-12 hours.
4. UNIT INDICATION button: Lights will illuminate to indicate the selected operation mode (COOL, DRY, FAN), fan speed (HIGH, MED, LOW), or if the water tank is full (WATER FULL).
5. TIMER button:
– If the unit is running, press to enter timed Switch-OFF mode.
– If the unit is off (standby mode), press to enter timed Switch-ON mode.
– Press the button again to cancel the timer operation. Use with the TEMP (+/-) buttons to set the time.
6. FAN SPEED button: Press to cycle through fan speeds: HIGH, MED, LOW.
7. POWER button: Press to turn the air conditioner ON or OFF. The power indicator will light when ON.
8. MODE button: Press to cycle through the operation modes: COOL -> DRY -> FAN -> HEAT (heating mode for cooling and heating models only).
What are the power source requirements and warnings for the ARCTIC WIND AP12018?
Before you insert the plug, please make sure the air conditioner is turned off. Follow these guidelines:
• The AC socket must be firm and reliable.
• Do not connect the portable air conditioner to a multiple socket outlet which is also being used for other electrical appliances.
• Do not use a damaged or improper AC socket.
• When unplugging the unit, hold the power plug securely and pull it out carefully.
• Do not use an extension cord.
How do I set the present time on the remote controller for the ARCTIC WIND AP12018?
To set the present time (Example: 10:30 AM):
1. Continually press the HOUR button for about 2 seconds. The time indicator will start flickering.
2. Press the HOUR button to set the hour. (Set to 10).
3. Press the MIN button to set the minutes. (Set to 30).
4. Press the ON/OFF button to confirm the set time. The unit will also automatically exit the time setting state after 15 seconds of inactivity.
NOTE: The timer function is based on the present time, so it’s important to set the present time correctly.
What precautions should I take when using the remote controller for the ARCTIC WIND AP12018?
When using the remote, point it at the air conditioner and press the desired button. The air conditioner will make a “dee-” sound to acknowledge the signal.
For proper operation, please observe the following points:
• Do not place the remote near high-temperature sources like an electric heating cushion or a radiator.
• Do not place the remote where it is directly exposed to sunlight or strong lights.
• Avoid dropping the controller.
• Do not place objects between the air conditioner and the remote controller.
• Do not splash water or other liquids on the controller.
• Do not put heavy objects on the controller.
• If the remote controller is not functioning, replace the batteries and try again.
How do I replace the batteries in the remote controller for the ARCTIC WIND AP12018?
If the air conditioner does not make an acknowledgment sound when a signal is transmitted, the batteries are likely exhausted and need replacement.
1. Remove the battery case cover by sliding it open in the direction of the arrow.
2. Take out the used batteries.
3. Replace with new batteries, paying attention to the “+” and “-” polarity markings.
4. Close the back cover.
How do I drain water from the ARCTIC WIND AP12018 when the internal tank is full?
The air conditioner evaporates most condensed water. However, if the internal water tank becomes full, the “FULL” lamp will illuminate, and the unit will stop running. Follow these steps to drain the water:
1. Unplug the air conditioner.
2. Disconnect the exhaust hose from the back of the unit.
3. Carefully move the conditioner to a suitable drain location or outdoors.
4. Remove the base stopper from the base water outlet to drain the water. There is approximately 1.5L of water in the tank.
5. Once the tank is drained, securely reinstall the base stopper.
6. Place the air conditioner back in its desired location, reconnect the exhaust hose, and plug in the unit. It should now operate normally.
How can I set up continuous drainage for my ARCTIC WIND AP12018?
In high humidity environments, you can use the continuous drainage function to avoid having to manually empty the tank. Note that this method may reduce the efficiency of the machine.
1. Pull out the partition plate stopper.
2. Connect a suitable hose (not provided) to the partition plate joint.
3. Lead the other end of the hose to a floor drain or a suitable area for draining the condensate.
When using this function, the hose must be placed horizontally and below the drainage hole. Avoid folding the hose or placing it on an uneven surface to ensure proper gravity-fed drainage.
How do I clean the air filter on my ARCTIC WIND AP12018?
If the air filter is blocked with dust, air flow will be reduced. Clean the filter once every two weeks. Always pull the plug out of the socket before cleaning.
1. Directly grasp the hook on the bottom of the air filter and pull to remove it in the direction of the arrow.
2. Wash the air filter by immersing it gently into warm water (about 40°C or 104°F) with a neutral detergent.
3. Rinse the detergent from the filter and dry it thoroughly in a shaded place.
4. Install the air filter back into its original place.
How should I maintain and store my ARCTIC WIND AP12018?
Cleaning the Unit Surface:
Clean the surface of the unit with a damp cloth, then dry using a duster or similar. Do not use chemical solvents like benzene or alcohol glazer, as they can scratch or damage the surface.
Prior to the Operating Season:
1. Check to see if the air inlets and outlets of the unit are blocked.
2. Check that the partition plate stopper and the base stopper are installed accurately.
3. Make sure the air filter is properly in place before operating the machine.
After the Operational Season (Storage):
1. Turn off the air conditioner and disconnect the power source.
2. Perform proper maintenance on the air filter and other parts.
3. Open the partition plate stopper and the base stopper to drain out any remaining water.
4. Operate the unit in FAN mode for half an hour to ensure the partition plate and the base are completely dry.
5. Use a plastic sheet to cover the unit to prevent dust or filth from entering.
What are the general safety cautions for using the ARCTIC WIND AP12018?
Occasion:
• Do not use the unit in a very narrow room with obstacles.
• Do not use the unit where sunlight is shining directly onto it to avoid surface color changing.
• Do not use the unit in or near water to avoid leakage of electricity.
• Do not use near gas appliances, fires, or in the vicinity of flammable liquids.
Others:
• Keep the unit one meter away from TV sets or radios to avoid electromagnetic interference.
• Do not use with the air outlet close to walls or cover the outlet to avoid overheating.
Serious Caution:
• Do not toggle over or incline the unit. If it does toggle, please unplug it at once and seek advice from your reseller.
• Do not spray with insecticide or other chemicals as the plastic case may be deformed.
How do I troubleshoot common problems with the ARCTIC WIND AP12018?
Before seeking repair or service, please check the following table:
| Trouble | Check | Action |
|---|---|---|
| Air conditioner does not operate at all | Is there power? | It is normal |
| Is it plugged in? | Push the plug into the wall socket | |
| Did the fuse or circuit breaker switch off? | Change the fuse or switch on | |
| The full lamp illuminates. | Discharge the condensed water from the base water outlet | |
| Cooling efficiency is not good | Is air inlet or outlet Blocked? | Clear the Blocked |
| Is there any other heat source in room? | Move the heat source | |
| Are air filters very dirty? | Clean the air filter | |
| Is indoor fan speed set at low? | Set suitable fan speed | |
| Too noisy and vibration | It is the inner liquid (refrigerant-generation) flowing inside. | It is normal |
| Is unit leveled? | Place it in a horizontal floor | |
| The machine starts and stops frequently | Is the voltage of the power source normal? | Keep the power source in rated |
| Is the air exhaust fixed rightly or be bended? | Try to keep the air exhaust horizontal not permit enlarge | |
| Are you add air exhaust yourself? | Don’t add air exhaust yourself and remove it | |
| Condensed water spills out when moving the unit | the base tank is nearly full? | Discharge the condensed water from the base water outlet |
When should I call for service for my ARCTIC WIND AP12018?
In case of a major malfunction, pull the plug out immediately and call for service. Contact a professional if you experience any of the following:
• The fuse and switch often break.
• The power cord superheats or the sleeve of the cord is broken.
• Something abnormal occurs.
How do I choose a location and install the ARCTIC WIND AP12018?
Selection of Installation Location:
Put the mobile air conditioner in a flat location where the air outlets cannot be covered up. Place the unit no less than 50cm (19.7 inches) away from a wall or other obstacle.
Installation of the Air Exhaust Hose:
1. First, take out the air exhaust hose.
2. Pull out the hot air outlet from the back of the unit.
3. Revolve the air exhaust adapter onto the end of the air exhaust hose. Turn it in the direction of the arrow for at least six rounds.
4. Revolve the air exhaust hose (with adapter attached) into the air conditioner in the same manner.
To uninstall, simply reverse the process by revolving the hose off the unit and then revolving the adapter off the hose.
How do I install the window kit for the ARCTIC WIND AP12018?
The window kit is designed to fit most standard “vertical” and “horizontal” window applications. You may need to improvise for certain window types.
1. Adjust the window slider kit to fit the width or height of your window. The kit has a minimum length of 27-1/2″ (70cm) and a maximum length of 48″ (122cm).
2. Use one screw to fix the installation boards (Board I and Board II) together at the desired length.
3. Place the assembled kit into the window opening and close the window securely against it.
4. Install the air exhaust adapter (attached to the hose) to the opening in the window kit.
How should I mount the air exhaust hose for the ARCTIC WIND AP12018 to maximize efficiency?
The air exhaust hose has a length of 20cm-160cm. To achieve maximum energy efficiency, it is suggested that the hose should be as short as possible. Pay attention to the following points:
1. Try to avoid bends in the hose.
2. Avoid bends near the exhaust air outlet on the unit. The bending point should be at least 50cm (20 inches) away from the unit’s exhaust air outlet.
3. Keep the entire exhaust hose as smooth as possible, avoiding any abrupt, steep-angled bends.
How do I use the interchangeable Air Outlet/Exhaust Air Outlet function on the ARCTIC WIND AP12018?
The unit has an interchangeable air outlet and exhaust air outlet function, which allows cooling air to be blown to the outdoor or other desired place. To use this function:
1. Remove the standard (cold) air outlet from the front of the unit.
2. Remove the exhaust air outlet (where the hose connects) from the back of the unit.
3. Interchange their locations: install the exhaust air outlet on the front of the unit and the standard air outlet on the back.
4. Connect the exhaust hose to the front of the unit and direct it to the desired location (e.g., outdoors).
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD ARCTIC WIND AP12018 (01) PDF DOCUMENT

want to order mesh air filter ZGYK1622 and mesh air filter ZGYK1623 for Arctic wind AP12018.also which filter is top one and which is bottom