Free English APUTURE SIDUS FOUR (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD APUTURE SIDUS FOUR (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


How does the APUTURE SIDUS FOUR power on automatically?

The APUTURE SIDUS FOUR automatically powers on whenever a power source is provided.


How do I power off the APUTURE SIDUS FOUR using the device interface?

To power off the APUTURE SIDUS FOUR, enter the Main Settings menu and select the Power icon.


What is the recommended procedure regarding antennas when powering the APUTURE SIDUS FOUR on or off?

It is recommended to power on and power off the APUTURE SIDUS FOUR with the antennas connected.


What kind of backup battery does the APUTURE SIDUS FOUR come with, and when is it activated?

The APUTURE SIDUS FOUR comes with an internal 3.7V / 1500mAh lithium battery which is activated when the external power source is disconnected.


What happens to power input when the external power supply is reconnected to the APUTURE SIDUS FOUR while the internal battery is active?

When the external power supply is connected again, input power will return to the power source and charging the backup battery if needed.


What should be done if the built-in spare battery life is very low on the APUTURE SIDUS FOUR?

Connect to external power supply as soon as possible.


What should be done if the DC power supply disconnects from the APUTURE SIDUS FOUR?

Connect the external V-Mount Battery or DC power supply port, please connect the external power supply as soon as possible.


What does the Control Method Status Bar on the APUTURE SIDUS FOUR Main Display show?

The Control Method Status Bar displays the current data source.


What are the Control Indicators shown on the APUTURE SIDUS FOUR Control Method Status Bar?

Orange = sACN

Yellow = Art-Net

Gray = No Control Source


How is the connection type indicated on the APUTURE SIDUS FOUR Control Method Status Bar if the control source is over Ethernet?

If the control source is over ethernet, “ETH” is indicated. For example, a Yellow background with “Art-Net over ETH” indicates the control protocol is Art-Net and the connection is via wired ethernet.


How is the connection type indicated on the APUTURE SIDUS FOUR Control Method Status Bar if the control source is from Wi-Fi?

If the control source is from Wi-Fi, “Wi-Fi” is indicated. For example, an Orange background with “sACN over WiFi” indicates the control protocol is sACN and the connection is via Wi-Fi.


What statuses are displayed on the Output Status Bar for each Output Port on the APUTURE SIDUS FOUR?

Good: Device connection and data are normal.

Linking: Ports are initiating CRMX connections.

Port No Data: Port No Data, Check Port Universe Settings or Check if Data Source Connection is Working.

No Wi-Fi Data: No Wi-Fi data is received, please check the control device is normal.

Ethernet No Data: No Ethernet Data Received, Please Check Control Device Is Working.

Wi-Fi signal is unstable: check if the Sidus Four antenna is installed properly, or check if there is occlusion or distance between the Sidus Four and the AP node.

Universe Error: Port Universe settings are out of protocol range, refer to protocol range settings: Art-Net is 0-32767, sACN is 1-63999.


What do the icons in the Power and Communications Status Bar signify on the APUTURE SIDUS FOUR?

Power Icon Description Status Indicator
Connected External 9-24 V DC Power Connected External 9-24 V DC Power Icon showing external power connection
V-Mount Power Icon Connected external V-Mount Battery power Icon showing V-Mount connection
Battery icon 1 Backup Battery power and remaining usage time Icon showing 40min indicator
Battery icon 2 Backup Battery is low, please connect to external power supply as soon as possible Icon showing low battery
Battery icon 3 Charging the Backup Battery Icon showing charging battery
Battery icon 4 Backup Battery is full Icon showing full battery
Ethernet icon 1 (white) Ethernet connected; data present White Ethernet icon
Ethernet icon 2 (red) Ethernet connected, but no data is present, please check that the Ethernet settings are correct Red Ethernet icon
Wi-Fi Icon 1 (White) Wi-Fi is in AP mode and connected with data present. White Wi-Fi AP icon with signal bars
Wi-Fi Icon 2 (Red) Wi-Fi is in AP mode, connected, but no data is being received. Please check if the Wi-Fi settings are correct and check that ethernet data is not also being received. Red Wi-Fi AP icon with signal bars
Wi-Fi Icon 3 (White) Wi-Fi is in STA mode, connected normally, and displaying Wi-Fi signal strength. White Wi-Fi STA icon with signal bars
Wi-Fi Icon 4 (Red) Wi-Fi is in STA mode, connected and displaying Wi-Fi signal strength, but no data is being received. Please check if the Wi-Fi settings are correct. Red Wi-Fi STA icon with signal bars
Wi-Fi Icon 5 (Red) Wi-Fi is in STA mode and not connected. Red Wi-Fi STA icon
Wi-Fi icon 1 (white) Wi-Fi Normal connection White Wi-Fi icon (generic)
Wi-Fi icon 2 (red) Wi-Fi is connected, but no data is being received, please check that the Wi-Fi settings are correct Red Wi-Fi icon (generic)

What is indicated by a low battery power status on the APUTURE SIDUS FOUR?

The built-in spare battery life is very low. Connect to external power supply as soon as possible.


What do the colors on the CRMX status indicators (Ports A-D) signify on the APUTURE SIDUS FOUR Main Display?

CRMX Enabled/Data is present: GREEN

CRMX Enabled/Data is not present: RED


How do you access Output Settings for a CRMX port on the APUTURE SIDUS FOUR?

Scroll the wheel to select the Output and Click to open the Output Settings.


What options are available in the Output Settings menu for a CRMX port on the APUTURE SIDUS FOUR?

In the Output Settings menu, set the Universe for the Port is set and where CRMX Linking options are available. Enabling or disabling the port and specifying the Linking Key for the Output Port is also set here.


How should a device be set up to link using the Linking Key on the APUTURE SIDUS FOUR CRMX outputs?

For devices that allow for linking via Linking Key, set their Linking Key to match the port to listen for. Put the device in “CRMX” Mode. If the device offers a “Port” or “Universe” selection, then select “A” or “1” to listen to the matching Output Port of Sidus Four.


When using Ethernet or Wi-Fi as the data source for the APUTURE SIDUS FOUR, what can the E-H XLR DMX ports output?

When using Ethernet or Wi-Fi as the data source of Sidus Four, the E-H port can output 1 Universe of data each. The Universe chosen in the Port Settings is displayed in the Main Display.


What happens when using DMX INPUT Ports as the data source for the APUTURE SIDUS FOUR?

When using DMX INPUT Ports as the data source for the Sidus Four, the E-H Ports automatically connect to the corresponding CRMX Ports above the port in the Main Display.


What settings can be configured in the Ethernet Settings interface of the APUTURE SIDUS FOUR?

In Ethernet Settings, select the Ethernet Protocol, IP mode, and set the Sidus Four network IP’s. The MAC address of the Sidus Four is also displayed here.


What are the Ethernet Protocol options available on the APUTURE SIDUS FOUR?

Protocol Option Setting
sACN Select sACN
Art-Net Select Art-Net
Automatic Allow Sidus Four to automatically detect the protocol present

What is the best practice regarding sACN and Art-Net usage on the APUTURE SIDUS FOUR Ethernet ports?

Best practice does not recommend using sACN and Art-Net on the same unmanaged network.


How is the IP address determined in the IP Mode Settings within the Ethernet Settings for the APUTURE SIDUS FOUR?

In IP Mode Settings, choose how the Sidus Four’s IP is to be determined. Choose “Auto(DHCP)” to allow the network DHCP Server to automatically populate Sidus Four’s IP Address, Subnet Mask, and Gateway IP. Choose “Static” to enter the information manually.


What settings can be configured in the Wi-Fi Settings interface of the APUTURE SIDUS FOUR?

In Wi-Fi Settings, turn Wi-Fi ON or OFF, select the Control Protocol Wi-Fi should use, the Wi-Fi Mode (AP or STA), enter SSID and password and choose Wi-Fi IP settings. The Wi-Fi MAC Address and Wi-Fi Module Firmware Version are also listed.


What is AP Mode for the APUTURE SIDUS FOUR Wi-Fi?

AP Mode: When set to AP mode, the Sidus Four’s Wi-Fi will act as a wireless access point and acts as the DHCP Server in the network.


What is STA Mode for the APUTURE SIDUS FOUR Wi-Fi?

STA Mode: When set to STA mode, the Sidus Four will act as a workstation to communicate with other devices, such as a network router or a Sidus Four in AP mode.


When the APUTURE SIDUS FOUR Wi-Fi is in AP Mode, what do the SSID and Password settings refer to?

When Wi-Fi is in AP Mode, then the SSID and Password refer to the wireless network other devices need to connect to in order to communicate with this Sidus Four in AP Mode. Both the SSID and Password are editable in the WiFi Settings interface.


When the APUTURE SIDUS FOUR Wi-Fi is in STA Mode, what does the SSID refer to?

When Wi-Fi is in STA Mode, the SSID (wireless network name) refers to the network for the Sidus Four to join. Under Password, Enter in the network password of the router.


What methods can be used to update the firmware on the APUTURE SIDUS FOUR?

The APUTURE SIDUS FOUR can be updated using Sidus Link Pro, Sidus Link, or via a file on the root drive of a USB-C flash drive.


How is a Batch Firmware Update performed on fixtures using the APUTURE SIDUS FOUR?

Step 1. Insert the USB stick with the latest firmware of the Aputure fixture into the Type-C USB port of the Sidus Four.

Step 2. Use the XLR-DMX port or wireless CRMX to connect to the lamp that needs to be updated. Please note that the lamp needs to support batch updates.

Step 3. Select Firmware Update.

Step 4. Choose whether to perform a Factory Reset after the Firmware Update is complete.

Step 5. Choose the firmware to use for the update and wait for the update to complete. If the fixture fails to upgrade, it will blink slowly and will need to be upgraded again. In addition, choose whether to restore the factory settings after the batch upgrade interface is completed.


What are the initial steps required before upgrading the APUTURE SIDUS FOUR firmware using the Sidus Link Pro App?

Step 1. Before upgrading, connect the iPad to a Wi-Fi network with Internet access and open the Sidus Link Pro app.

Step 2. “Exit” the Scene to enter the Sidus Link Pro settings interface. Note: Exiting a Scene will stop DMX output to the lighting fixtures from Sidus Four.

Step 3. Click on the Library.

Step 4. Click on Firmware.

Step 5. Find Sidus Four and click to download the firmware.

Step 6. After downloading, switch the iPad’s Wi-Fi network to the Wi-Fi network of the Sidus Four that needs to be upgraded.

Step 7. Return to the Connection Management interface.

Step 8. Click on Wireless Transceiver, then click Firmware Upgrade and Wi-Fi Upgrade in the top right corner.


What are the steps to perform a Firmware Update on the APUTURE SIDUS FOUR using a USB Flash Drive?

Step 1. Download the latest firmware for Sidus Four from the Aputure.com to a USB-C flash drive.

Step 2. Ensure that the file is on the root level of the flash drive.

Step 3. Insert the flash drive into the USB-C port of Sidus Four.

Step 4. Select “Update” from the Main Settings menu and then select “Update”.

Step 5. Check that the update file is detected and then select “Yes.”

Step 6. Wait for the upgrade to complete.


What languages does the APUTURE SIDUS FOUR support?

The APUTURE SIDUS FOUR supports both English and Chinese.


How do I perform a Factory Reset on the APUTURE SIDUS FOUR using the Settings Menu?

To reset the unit to Factory settings, select Factory Reset from the Settings Menu. In the Factory Reset interface, change Sidus Four’s Factory Reset default language and select whether to Unlink all connected CRMX devices. Choosing the “Unlink All CRMX: OFF” option allows for a Factory Reset while maintaining the Sidus Four output CMRX links and Linking Keys.


What is the shortcut for a factory reset on the APUTURE SIDUS FOUR?

A 3 second press of the Select Wheel is a shortcut to a factory reset of Sidus Four. There is a 3-second countdown with the option to cancel the factory reset.


What are the default factory settings restored upon Factory Reset for the APUTURE SIDUS FOUR?

Component Default Setting
ABCD CRMX Outputs Unlink all CRMX Receivers; restore Outputs to: A: Universe 1; B: Universe 2; C: Universe 3; D: Universe 4
All Wireless Output Ports’ Linking Keys reset to “00000000”.
EFGH XLR-DMX ports Output Universes reset to: 5, 6, 7, 8
Ethernet Settings Automatic detection of Ethernet Control Protocols; DHCP/automatic assignment of IP information
Wi-Fi Automatic detection of Wi-Fi Control Protocols; IP assignment reset; Wi-Fi SSID and Password reset to default; Wi-Fi Mode reset to AP.
Batch Firmware Update utilize CRMX for updates; firmware updates do not trigger a Factory Reset of the updated device., after the completion of the update does not restore the factory settings
Language English; default language after a Factory Reset can be altered in Language Settings.

What is the maximum number of CRMX and DMX outputs usable when the APUTURE SIDUS FOUR has a wired Ethernet connection?

A maximum of (4) CRMX and (4) DMX outputs can be utilized.


How do I establish a wired Ethernet connection between the control device and the APUTURE SIDUS FOUR?

Connect the control device to Sidus Four with a network cable. When the connection is complete, it is possible to connect properly on the Sidus Four and the control device.


What visual indicators show the data connection status when using wired Ethernet on the APUTURE SIDUS FOUR?

The Sidus Four feature bar in the upper right corner of the screen shows the red Ethernet Network icon, and the feature bar in the middle of the screen shows “Ethernet has no data.”


What are the steps for using sACN Multicast control with the APUTURE SIDUS FOUR?

Step 1. Setting the universe of the output on the control device and initiating the multicast output.

Step 2. Set the universe value of the port that needs to be used on the Sidus Four. Set the Sidus Four universe to the same as the control device. When returning to the main interface, the red Ethernet icon in the top right corner of the screen turns white, and the error report in the product status bar in the middle of the screen no longer contains the error of port A. At the same time, port A turns green, indicating that the data connection is normal.

Step 3. Set the CRMX menu on the lamp;

Step 4. If the fixture has previously been connected to another CRMX emitter, select “Unconnect.”

Step 5. On the Sidus Four go to the settings screen for port A, select and click “Connect.” At this point, the Sidus Four display bar says “A- is connecting.”

Step 6. This completes the process of connecting the Sidus Four to the control device and the luminaire, and the remaining ports can be matched by the universe on the control device and the Sidus Four in the same way, and then connected to the luminaire.


What is required for using sACN Unicast control with the APUTURE SIDUS FOUR regarding network segmentation and addressing?

The use of unicast control requires the Sidus Four to be in the same network segment as the IP address of the control device, and the IP address of the Sidus Four that needs to send data is input on the control device.


What steps are necessary to manually set the IP address on the APUTURE SIDUS FOUR for sACN Unicast control if the control device does not support DHCP?

Step 1. First, query the IP address and submask of the current control device on the control device.

Step 2. Check IP address and submask at network connection when using computer control.

Step 3. After querying or setting the IP address and submask of the control device, the next step is to set the IP address of the Sidus Four on the Sidus Four. Open the Ethernet settings interface of Sidus Four, because the control device does not support DHCP function, so under DHCP Sidus Four can not get to the IP address, enter the IP settings to change the automatic IP to manual IP, and then manually set the IP.

Step 4. Note: the IP address of the Sidus Four cannot be set to be exactly the same as the control device.

Step 5. Finally, the universe of the port that needs to be used is set to the same as the control device in the Sidus Four; After the setup is complete, we can see that the red Ethernet icon in the upper right corner of the Sidus Four screen turns white, the error report in the product status bar in the middle of the screen no longer contains the error of port A, and port A turns green, indicating that the data connection is normal.

Step 6. Set the CRMX menu on the lamp;

Step 7. If the fixture has previously been connected to another CRMX emitter, select “Unconnect.”

Step 8. On the Sidus Four go to the settings screen for port A, select and click “Connect.” At this point, the Sidus Four display bar says “A- is connecting.”

Step 9. This completes the process of connecting the Sidus Four to the control device and the luminaire, and the remaining ports can be matched by the universe on the control device and the Sidus Four in the same way, and then connected to the luminaire.


What is required for using Art-Net broadcast control with the APUTURE SIDUS FOUR?

Using broadcast control requires the Sidus Four to be in the same network segment as the IP address of the control device.


What is the final step for Art-Net broadcast control connection after setting the universe on the control device for the APUTURE SIDUS FOUR?

Finally, the universe of the port that needs to be used is set to the same as the control device in Sidus Four; After setting up, we can see that the state of port A turns green, indicating that the data connection is normal.


What steps are required for ArtNet unicast control between a device and the APUTURE SIDUS FOUR?

Step 1. It is necessary to control the device and Sidus Four in the same network segment, and set the target IP address on the control device, that is, the IP address of the target Sidus Four, and finally match the universe of the port with the universe of the control device to achieve communication. Similarly, first of all, we need to set the IP address of Sidus Four to the same network segment.

Step 2. After the IP address is set up, we need to set the target address of unicast in the control device, which is the IP address we set on the Sidus Four.

Step 3. After completing the setting of the IP network segment and the target address, it is finally necessary to match the universe and control device of Sidus Four and connect the lamp through CRMX.


What is the role of the APUTURE SIDUS FOUR when using Wi-Fi sACN / Art-Net input to its outputs?

Sidus Four acts as a wireless access point (AP mode), and the Sidus Link Pro App directly connects to Sidus Four’s Wi-Fi network.


What is the first step when setting up Wi-Fi sACN / Art-Net input for the APUTURE SIDUS FOUR in AP mode?

Turn on the Wi-Fi network on Sidus Four, set the Wi-Fi mode to AP mode, and configure a name and password for the Wi-Fi network.


What is the function of the E-H ports on the APUTURE SIDUS FOUR regarding wired DMX?

Sidus Four’s E-H port supports DMX input or output. The DMX ports are XLR-5 Pin female.


What hardware is included with the APUTURE SIDUS FOUR for use with XLR-5 Pin DMX ports when using them as inputs?

Included with Sidus Four, are (4) male to male DMX adapters (turnarounds). When E-H are used as DMX inputs, the male to male turnarounds may be required.


In the scenario where the APUTURE SIDUS FOUR receives wired DMX input (Ports E-H) which connects directly to CRMX outputs (Ports A-D), how do the ports correspond?

One cable corresponds to one universe. Each DMX port and CRMX port correspond one-to-one: E → A, F → B, G → C, H → D; there is no need to set the port universe on Sidus Four in this scenario except as a label for user reference.


What is displayed on the APUTURE SIDUS FOUR Main Display when it is receiving wired DMX data into Port E?

When the Lighting Console sends DMX data into Port E, the Main Display shows Port E as “DMX-IN”, and an arrow from Port E points to Port A. Port A shows a green CRMX background indicating that data is present.


What must be done to a fixture previously linked to another transmitter before connecting it to the APUTURE SIDUS FOUR via CRMX?

If the fixture was previously linked to another transmitter, unlink the fixture.


How do you initiate the CRMX Linking Signal for an output port on the APUTURE SIDUS FOUR?

Click “Link” in Output Port A to initiate the CRMX Linking Signal for that port.


What display change occurs on the APUTURE SIDUS FOUR Main Display after initiating the Link Signal for CRMX?

After initiating the Link Signal, it will display “A-Linking…” in the status bar on the Main Display.


What is noted regarding interference when using CRMX and Bluetooth simultaneously on the APUTURE SIDUS FOUR?

Since CRMX and Bluetooth both operate on the 2.4GHz band, interference may occur. Therefore, Sidus Four only supports connecting to one CRMX Bluetooth at a time. When using CRMX Bluetooth control, the other three CRMX ports must be disabled.


What input/output capacity does the Sidus Four CRMX BT IN feature support?

Sidus Four CRMX BT IN supports 1 CRMX output and 1 wired DMX output.


What prerequisite must be met on the APUTURE SIDUS FOUR before connecting via CRMX Bluetooth using the Sidus Link App?

In the Main Settings, enter the Update Interface and ensure that Sidus BT is OFF.


What is the next step after ensuring Sidus BT is OFF for CRMX Bluetooth connection setup on the APUTURE SIDUS FOUR?

Connect to the Wi-Fi network of Sidus Four and enter the password found in the WiFi Settings.


How are the CRMX ports identified when using CRMX Bluetooth devices with the APUTURE SIDUS FOUR?

The prefix of the 4 CRMX names of Sidus Four will be the same as the Wi-Fi name, differentiated by port numbers A-D (e.g., Sidus Four-1112DB_A).


What should be done after connecting to a CRMX device in the Sidus Link Pro Connection Management screen?

After connecting, click the right “>” to enter the settings.


How are DMX Universes assigned to CRMX ports A, B, C, and D when using Sidus Link Pro as the control device with CRMX Bluetooth on the APUTURE SIDUS FOUR?

A, B, C, and D correspond to Universe 1, 2, 3, and 4, respectively if using Sidus Link Pro as the control device.


What indicates a successful CRMX Bluetooth connection status on the APUTURE SIDUS FOUR Main Display?

The chosen port is connected on the Main Display of Sidus Four.


What mounting hardware is included with the APUTURE SIDUS FOUR for attaching it to a stand?

The Sidus Four has a 3/8 ” threaded mount on the bottom of the unit and a 3/8 ” Anti Twist Screw Baby Pin Adapter is included.


How do you attach the mounting adapter to the bottom of the APUTURE SIDUS FOUR?

Screw the adapter into the bottom of the Sidus Four.


How can wireless performance be improved when mounting the APUTURE SIDUS FOUR?

Raising Sidus Four above people and other obstructions can greatly improve wireless performance.


What are the product specifications for the APUTURE SIDUS FOUR?

Specification Detail
Product Name Sidus Four
Product Size 187*186*69mm(不含天线)
Product Weight 1.4Kg(不含天线)
Operating temperature -20°C ~ 55°C
storage temperature -40°C ~ 80°C
Protection level IP65
Package Size 370*315*155mm
Product gross weight 4.56Kg

What are the core technical specifications for the APUTURE SIDUS FOUR protocol compatibility and interfaces?

内容 (Content) 描述 (Description)
Compatible Protocol CRMX, DMX, Art-Net, sACN, Sidus Mesh
100m Ethernet Interface RJ45 x 2 Ports
Wi-Fi Built-in 5GHz WiFi module
Wired Dmx Interface XLR-5 Pin female socket x 4
CRMX Built-in TimoTwo module x4
Powered By 5.5mm DC interface: 9-24V; V-mount battery: 12V-16.8V
Type-C Interface Built-in battery; Output: 5V/0.5A; Product upgrade, batch upgrade of lighting fixtures
Sidus Mesh Built-in Sidus BT; Compatible with Sidus Mesh Mixing Control
Protection Level IP65

What are the power consumption and shell/installation details for the APUTURE SIDUS FOUR?

Specification Detail
Product Power Consumption General: 6W; Max: 17W
Shell/Installation Black red, aluminum shell; 3/8″ thread

What are the Antenna Information details for the APUTURE SIDUS FOUR?

Specification Detail
Frequency band 2.4 to 2.49 GHz, 4.9 to 5.8GHz
2.4G gain 3.6 dBi maximum
GHz gain 5.1 dBi max
Size $13.0mm×206mm
Weight 25g
Interface TNC

What are the temperature specifications for the APUTURE SIDUS FOUR?

Specification Detail
Working temperature -20°C – 55°C
Storage temperature -40°C – 80°C

What are the display specifications for the APUTURE SIDUS FOUR?

Specification Detail
Type TFT
Display size 95.04 x 23.35mm
Resolution 480*128

What are the transmission distance and working frequency specifications for the APUTURE SIDUS FOUR?

Specification Detail
Transmission Distance*1 CRMX: ≤800m; Wi-Fi: 800m; Sidus BT: ≤300 m transmit only
Working Frequency Wi-Fi: AP mode 5GHz, STA mode 2.4GHz or 5GHz; CRMX/Sidus BT: 2.4GHz

What are the battery specifications for the APUTURE SIDUS FOUR?

Specification Detail
Battery Life 80 minutes
Battery Capacity 3.7V 1500mAh
Charging Time 0.5h

What are the upgrade methods and external power adapter specifications for the APUTURE SIDUS FOUR?

Specification Detail
Upgrade Method Sidus Link App; Sidus Link Pro App; USB
External Power Adapter AC IN: 100-240V; DC OUT: 9V/18W; Length: 3M

What basic safety precautions should always be followed when using the APUTURE SIDUS FOUR unit?

Read and understand all instructions before using.

Please keep MT Pro away from diskette, credit cards, monitors, mechanical watches, mobile phones, medical devices (pacemakers), etc.

Close supervision is necessary when any fixture is used by or near children. Do not leave the fixture unattended while in use.

Care must be taken as burns can occur from touching hot surfaces.

Do not operate the fixture if a cord is damaged, or if the fixture has been dropped or damaged, until it has been examined by qualified service personnel.

Position any power cables such that they will not be tripped over, pulled, or put into contact with

If an extension cord is necessary, a cord with an amperage rating at least equal to that of the fixture should be used. Cords rated for less amperage than the fixture may overheat.

Always unplug the lighting fixture from the electrical outlet before cleaning and servicing, or when not in use. Never yank the cord to remove the plug from the outlet.

Let the lighting fixture cool completely before storing. Unplug the power cable from lighting fixture before storing and store the cable at assigned space of the carrying case.

To reduce the risk of electric shock, do not immerse this fixture in water or any other liquids.

To reduce the risk of fire or electric shock, do not disassemble this fixture. Contact cs@aputure.com or take the lighting fixture to qualified service personnel when service or repair is required. Incorrect reassembly may cause electric shock when the lighting fixture is in use.

The use of any accessory attachment not recommended by the manufacturer may increase the risk of fire, electric shock, or injury to any persons operating the fixture.

Please power this fixture by connecting it to a grounded outlet.

Please do not block the ventilation or do not look at the LED light source directly when it is powered on. Please do not touch the LED light source in any condition.

Please do not place the LED lighting fixture near any flammable object.

Only use a dry microfiber cloth to clean the product.

Please do not use the light fixture in wet condition on account of electric shock may be caused.

When hanging the product overhead, always ensure an extra safety measure has been attached – such as a safety chain- that is certied for the weight of the product.


What is noted regarding malfunctions caused by unauthorized disassembly or accessories on the APUTURE SIDUS FOUR?

Any malfunctions caused by unauthorized disassembly are not covered by the warranty. The user may pay for maintenance.

Please note that any malfunctions caused by using unauthorized accessories are not covered by the warranty. The user may pay for maintenance.


What actions might void the user’s authority to operate the APUTURE SIDUS FOUR equipment according to the FCC warning?

Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.


If the APUTURE SIDUS FOUR equipment causes harmful interference to radio or television reception, what actions are encouraged for the user?

The user is encouraged to try reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment to an outlet on a different circuit than the receiver is connected to.

Consult the dealer or an experienced radio/TV technician for help.


CLICK HERE TO DOWNLOAD APUTURE SIDUS FOUR (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.