What do the safety symbols on the ANKER SOLIX C300 A1722 indicate?
The ANKER SOLIX C300 A1722 uses the following symbols to convey safety information:
| Symbol | Description |
|---|---|
| Caution | Indicates a low-risk hazard. Failure to avoid this hazard could result in minor or moderate injury. |
| Warning | Indicates a hazard with a moderate level of risk. Failure to avoid this hazard could result in death or serious injury. |
| Danger | Indicates a highly risky hazard. Failure to avoid this hazard could result in death or serious injury. |
| Refer to operating instructions | Indicates that users should refer to operating or installation instructions before proceeding. |
| Risk of electric shock | Indicates components that present risk of electrical shock. |
| Caution, hot surface | Indicates that equipment surfaces may be hot and pose a burn risk. |
| PE conductor terminal | Protective conductor terminal. |
What safety precautions should be followed when using the ANKER SOLIX C300 A1722?
When using the ANKER SOLIX C300 A1722, basic precautions should always be followed, including:
Read all the instructions before using the product.
To reduce the risk of injury, close supervision is necessary when the product is used near children.
Do not put fingers or hands into the product.
Do not expose the product to rain or snow.
Use of an attachment not recommended or sold by power pack manufacturer may result in a risk of fire, electric shock, or injury to persons.
To reduce risk of damage to the electric plug and cord, pull the plug rather than the cord when disconnecting the power pack.
Do not use a battery pack or appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury.
Do not operate the power pack with a damaged cord or plug, or a damaged output cable.
When charging the internal battery, work in a well ventilated area and do not restrict ventilation in any way.
Do not use the product in excess of its output rating. Overload outputs above rating may result in a risk of fire or injury.
When charging a device, the product may feel warm. This is a normal operating condition and should not be cause of concern.
Do not disassemble the product. Take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire, electric shock and injury to persons.
To reduce the risk of electric shock, unplug the power pack from the outlet before attempting any instructed service.
What are the grounding instructions for the ANKER SOLIX C300 A1722?
The ANKER SOLIX C300 A1722 must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. This product is equipped with a cord with an equipment grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Warning: Improper connection of the equipment grounding conductor may result in an electric shock. Check with a qualified electrician if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.
How should the ANKER SOLIX C300 A1722 be handled and maintained to ensure safety?
Follow these safety guidelines for handling and maintenance:
Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that the safety of the product is maintained.
Caution: Risk of explosion if the battery is replaced by an incorrect type.
Do not expose a power pack to fire or excessive temperature. Exposure to fire or temperature above 130 degrees Celsius may cause explosion.
In case of fire, only a dry powder fire extinguisher is suitable for the product.
Do not clean the product with harmful chemicals or detergents.
Misuse, dropping or excessive force may cause product damage.
When disposing of secondary cells or batteries, keep cells or batteries of different electrochemical systems separate from each other.
Disposal of a battery into a fire or hot oven, or mechanically crushing or cutting off a battery, can result in an explosion.
Leaving a battery in an extremely high-temperature environment or low air pressure can result in an explosion or leakage of flammable liquid or gas.
Unplug the AC power cable to disconnect from the line voltage.
What precautions should be observed when working on the batteries of the ANKER SOLIX C300 A1722?
The following precautions should be observed when working on batteries:
Disconnect the charging source prior to connecting or disconnecting battery terminals.
Do not wear any metal objects including watches and rings.
Do not lay tools or metal parts on top of batteries.
Use tools with insulated handles.
Wear rubber gloves and boots.
Determine if battery is either intentionally or inadvertently grounded. Contact with any part of a grounded battery can result in electric shock and burns by high short-circuit current. The risk of such hazards can be reduced if grounds are removed during installation and maintenance by a skilled person.
What are the storage and maintenance instructions for the ANKER SOLIX C300 A1722?
To maintain the ANKER SOLIX C300 A1722 properly, follow these instructions:
1. Store product in a cool and dry place. Do not store the product in hot or humid environment.
2. If the product is not used for long periods of time, you should charge and discharge once every three months.
3. Keep the product on a flat surface when using, charging, and storing.
4. Store the product between 32 degrees Fahrenheit to 104 degrees Fahrenheit (0 degrees Celsius to 40 degrees Celsius).
5. Do not use or store the power station in direct sunlight for a long period, such as in a car, cargo bed, or any other place where it will be exposed to high temperatures. Doing so may cause the product to malfunction, deteriorate, or generate heat.
What are the technical specifications for the ANKER SOLIX C300 A1722?
The following table lists the detailed specifications for the ANKER SOLIX C300 A1722:
| Operating Altitude | 2000m |
| Pollution | PD2 |
| Power Distribution System | TN, TT |
| AC Output Short-Circuit Current | 100Apeak / 13.7Arms |
| DC Input Wiring | VW-1, 200 degrees C, 600V, 14AWG |
| DC Output Wiring | VW-1, 200 degrees C, 600V, 14AWG |
| AC Output Wiring | VW-1, 200 degrees C, 600V, 18AWG |
| PE Wiring | VW-1, 200 degrees C, 600V, 14AWG |
| Overvoltage Category | II |
| Enclosure | IP20 |
| Storage Temperature Range | 0 degrees C to 40 degrees C |
| Charge Temperature Range | 0 degrees C to 40 degrees C |
| Discharge Temperature Range | -20 degrees C to 40 degrees C |
| Battery Type | LiFePO4 |
| Battery Structure Formulation | 6S3P |
| Battery Capacity | 15000mAh / 288Wh |
| Battery Nominal Voltage | 19.2VDC |
| Size | 16.4 x 16.1 x 24.0 cm / 6.5 x 6.3 x 9.5 in |
| Net Weight | 4.13kg |
How should the ANKER SOLIX C300 A1722 be used in Inverter mode?
Under Inverter mode, to reduce the risk of electric shock, connect only one electrical equipment to the socket outlet of the ANKER SOLIX C300 A1722.
The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. The length of the output cords externally connected to the AC output port of the device cannot exceed 10m.