How do I enter the Factory Test Procedure on the ALLIANCE AWN63RSN116TW01?

To enter the test mode for the ALLIANCE AWN63RSN116TW01, follow these steps:

1. Disconnect electrical power from the unit.

2. Reconnect electrical power to the unit.

3. Wait about 10 seconds.

4. Turn the Cycle Selection knob to the opposite of Normal Eco and stay on that selection for at least one second.

5. Press and hold the Start/Pause button.

6. Change the Cycle Selection knob to Normal Eco within 5 seconds.

7. Stay on Normal Eco for at least one second, and the control will enter the Factory Test Mode.


How do I advance to the drain and spin cycle on the ALLIANCE AWN63RSN116TW01?

To advance the ALLIANCE AWN63RSN116TW01 to the final spin/drain step, ensure the EXTRA RINSE option is in the OFF position, then follow these steps:

1. Press and hold the START/PAUSE button for about three seconds until the current cycle status light turns off.

2. Continue holding the START/PAUSE button for another 7 to 8 seconds until the SPIN light comes on, then release the button.

3. If the lid was unlocked, the LID LOCK light will come on and the lid will lock. Once locked, the machine will start to drain and spin.

4. After the final spin/drain step, the control will reset to normal operation.


How do I enable or disable audio signals on the ALLIANCE AWN63RSN116TW01?

For the ALLIANCE AWN63RSN116TW01, you can control audio signals as follows:

To toggle the end of cycle signal, hold the Extra Rinse button for three seconds. A one-second tone will sound to confirm if the signal is turned off or on.

To toggle audio signals that sound when a knob selection is changed or when the Start/Pause or Extra Rinse buttons are pressed, hold the Extra Rinse button for 10 seconds. A three-second tone will sound to confirm if the signals are turned off or on.

Additionally, the Status lights will be lit in an upward pattern when the signal is turned on, and in a downward pattern when the signal is turned off.


How can I enable the Rapid Advance feature on the ALLIANCE AWN63RSN116TW01?

When Rapid Advance is enabled on the ALLIANCE AWN63RSN116TW01, pressing the START/PAUSE button during Run Mode will advance the current cycle step to the next enabled step. To enter this mode:

1. Press and hold both the START/PAUSE and EXTRA RINSE buttons for three seconds. The Status lights will be lit in an upward pattern when rapid advance is turned on.

2. Press the START/PAUSE button to advance through the cycle.

3. To exit rapid advance, press and hold both the START/PAUSE and EXTRA RINSE buttons for three seconds. The lights will be lit in a downward pattern when the signal is turned off.


What are the recommended torque specifications for the ALLIANCE AWN63RSN116TW01 drive bell?

When replacing or reinstalling the drive bell on the ALLIANCE AWN63RSN116TW01, use the following torque specifications:

Table: Drive Bell Torque

Location: Drive Bell to Washtub and Hub | Minimum: 100 inch-pounds [11.3 Nm] | Maximum: 140 inch-pounds [15.8 Nm]

Location: Drive Bell to Top of Drive Shaft | Minimum: 60 inch-pounds [6.78 Nm] | Maximum: 100 inch-pounds [11.3 Nm]


How do I properly level the ALLIANCE AWN63RSN116TW01?

To ensure the ALLIANCE AWN63RSN116TW01 is level:

1. Place a level on the cabinet top and check if the washer is level from side to side and front to back.

2. If the washer is not level, tilt the washer back to access the front leveling legs. Loosen the locknuts and adjust the legs by screwing them into or out of the washer base.

3. Once adjusted, tilt the washer forward on the front legs and lower it back down into position to set the rear self-leveling legs.

4. The washer must not rock. When the washer is level and does not rock, tighten the locknuts securely against the bottom of the washer base.


What should I check if the ALLIANCE AWN63RSN116TW01 has no hot water?

If the ALLIANCE AWN63RSN116TW01 has no hot water and shows WASH, RINSE STATUS lights flashing 1 or 2 times, perform the following checks:

1. Is the water supply faucet closed? If yes, open the faucet.

2. Is the water supply cold? If yes, check if the hoses are reversed or check the water heater.

3. Is the hot water fill hose kinked? If yes, straighten or replace the hose.

4. Is the mixing valve screen or screen in the outer end of the fill hose nearest the water supply faucet clogged? If yes, disconnect the fill hose and clean or replace the screen.

5. If there is proper voltage output from the output board to the mixing valve hot solenoid, check if the hot solenoid is inoperative. If inoperative, replace the valve.

6. Check if the pressure hose is clogged or damaged. If it is, remove and clean or replace the hose.

7. Check if the temperature selector switch is operating properly. If not, ohm out the switch using the wiring diagram.


What should I do if the ALLIANCE AWN63RSN116TW01 tub does not empty?

If the ALLIANCE AWN63RSN116TW01 tub does not empty (WASH, RINSE STATUS lights flash 3 or 4 times, or remain on continuously), check these items:

1. Is the drain hose kinked? If yes, straighten the hose.

2. Are there excessive suds in the machine? If yes, use low-sudsing, high efficiency detergent.

3. Is the drain hose out of the hose retainer clip in the base of the cabinet? If yes, install the drain hose into the base retainer block.

4. Is there proper voltage present at the pump? If not, check if the wiring from the pump to the drive board is broken, loose, or incorrect. If voltage is present but the pump does not work, replace the pump.

5. Is there proper voltage present at the drive board? If not, replace the drive board.

6. Is the pump rated at the correct frequency (50 or 60 Hertz)? If not, use the correct pump.

7. Is there an obstruction in the outer tub outlet hose? If yes, remove the obstruction.