How do I enter the Factory Test Procedure on the ALLIANCE ZWN43RSN115CW01?

To enter the Factory Test Procedure on the ALLIANCE ZWN43RSN115CW01, follow these steps:

1. Disconnect electrical power from the unit.

2. Reconnect electrical power to the unit.

3. Wait about 10 seconds.

4. Turn the Cycle Selection knob to the opposite of Normal Eco. Stay on that selection for at least one second.

5. Press and hold the Start/Pause button.

6. Change the Cycle Selection knob to Normal Eco within 5 seconds or the Start press will be invalid.

7. Stay on Normal Eco for at least one second. The control will enter the Factory Test Mode.

8. To advance through the sequence of test steps, press the Start/Pause button.


What are the steps for the Factory Test Procedure on the ALLIANCE ZWN43RSN115CW01?

The Factory Test Procedure for the ALLIANCE ZWN43RSN115CW01 consists of several steps:

Number Step
0 Show Mode
1 Cycle Switch
2 Temperature Switch
3 Load Size Switch
4 Extra Rinse
5 Lid Switch
6 Hot Fill
7 Cold Fill
8 Pressure Sensor Fill
9 Lid Lock Check
10 Long Stroke Agitate
11 Short Stroke Agitate
12 Factory Spin
13 Unbalance Switch Test
14 Breakaway
15 Power Down

What should I check if my ALLIANCE ZWN43RSN115CW01 has a Pressure Sensor Error?

If the ALLIANCE ZWN43RSN115CW01 indicates a Pressure Sensor Error (WASH, RINSE lights flash 1 time), follow these steps:

1. Check if the pressure sensor is connected to the front end control properly. If not, connect the sensor to the front end control.

2. Check if the pressure sensor harness is damaged. If it is, replace the pressure sensor harness.

3. If the error is still displayed, replace the pressure sensor. If the problem persists, replace the front end control.


How do I level the ALLIANCE ZWN43RSN115CW01?

To properly level your ALLIANCE ZWN43RSN115CW01, follow these instructions:

1. Place a level on the cabinet top and check if the washer is level from side to side and front to back.

2. If the washer is not level, tilt the washer back to access the front leveling legs. Loosen the locknuts and adjust the legs by screwing them into or out of the washer base.

3. Once adjusted, tilt the washer forward on the front legs and lower it back down into position to set the rear self-leveling legs.

4. The washer must not rock. When the washer is level and does not rock, tighten the locknuts securely against the bottom of the washer base. If these locknuts are not tight, the washer will not remain stationary during operation.


What should I do if my ALLIANCE ZWN43RSN115CW01 is experiencing excessive vibration?

If your ALLIANCE ZWN43RSN115CW01 is vibrating excessively, check the following:

1. Ensure the shipping plug has been removed from the base.

2. Verify if there is an unbalanced load in the tub. If so, stop the washer, redistribute the load, and restart.

3. Check if any centering springs are broken, disconnected, or in the wrong position. Ensure green springs are in the front two positions.

4. Check if the washer is unleveled. If so, adjust the leveling legs and make sure rear leveling legs are free.

5. Check if the washer is installed on a weak, spongy, carpeted, or built-up floor. Relocate the washer or support the floor to eliminate this condition.

6. Check if cabinet screws are incorrect or loose.

7. Check if the base is damaged from being dropped.

8. Check if there is lubricant on the pivot dome and/or base friction ring.

9. Check if a partial liquid filled balance ring is leaking.

10. Check if the friction ring is broken.


What is the required Drive Bell Torque for the ALLIANCE ZWN43RSN115CW01?

When replacing or reinstalling the drive bell on your ALLIANCE ZWN43RSN115CW01, torque the bolts to the following specifications:

Location Minimum Maximum
Drive Bell to Washtub and Hub 100 inch-pounds [11.3 Nm] 140 inch-pounds [15.8 Nm]
Drive Bell to Top of Drive Shaft 60 inch-pounds [6.78 Nm] 100 inch-pounds [11.3 Nm]

How do I test the mixing valve solenoids on the ALLIANCE ZWN43RSN115CW01?

Test the mixing valve solenoids on your ALLIANCE ZWN43RSN115CW01 using an Ohm meter. Refer to the table below for expected resistance readings:

Valve Type Resistance
120 Volt valves 900 – 1100 Ohms
240 Volt valves 3200 – 4000 Ohms

Resistance readings slightly out of these ranges may be due to meter conditions and do not necessarily indicate mixing valve failure.