FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF USER GUIDE
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF USER MANUAL
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF OWNER GUIDE
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF OWNER MANUAL
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF REFERENCE GUIDE
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF INSTRUCTION GUIDE
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF REFERENCE MANUAL
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF INSTRUCTION MANUAL
FREE ENGLISH WHIRLPOOL WFG720H0A (01) PDF OPERATING INSTRUCTIONS
CLICK HERE TO DOWNLOAD WHIRLPOOL WFG720H0A (01) PDF MANUAL
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the product model numbers for this 30″ (76.2 cm) Freestanding Gas Range?
| WFG540H0A | WFG714HLA | WFG720H0A |
| WFG540H0E | WFG715H0E | WFG745H0F |
| WFG710H0A |
What type of gas is this range factory set for and can it be converted?
Natural Gas:
This range is factory set for use with Natural gas. The model/serial/rating plate is located on the oven frame behind the top right side of the oven door and has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
What are the gas supply line requirements?
Provide a gas supply line of 3/4″ (1.9 cm) rigid pipe to the range location. A smaller pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be 1/2″ (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.
What are the specifications for a flexible metal appliance connector?
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, 1/2″ (1.3 cm) or 3/4″ (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
A 1/2″ (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the range.
Is a shutoff valve required for the gas supply line?
Yes, the supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as in an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the range.
What are the electrical requirements for this range?
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
What are the product dimensions?
| A. | 27 7/8″ (70.8 cm) max. depth with handle |
| B. | 36″ (91.4 cm) cooktop height (max.) with leveling legs screwed all the way in* |
| C. | 46 7/8″ (119.1 cm) overall height (max.) with leveling legs screwed all the way in* |
| D. | 29 7/8″ (75.9 cm) width |
| E. | 25 7/16″ (64.3 cm) depth. Back of range to front of cooktop** |
| F. | Model/serial rating plate (located on the oven frame behind the top right side of the oven door) |
* Range can be raised approximately 1″ (2.5 cm) by adjusting the leveling legs.
** Front of door and drawer may extend further forward depending on styling.
What are the required cabinet opening dimensions?
Cabinet opening dimensions shown are for 25″ (64.0 cm) countertop depth, 24″ (61.0 cm) base cabinet depth and 36″ (91.4 cm) countertop height.
| A. | 18″ (45.7 cm) upper side cabinet to countertop |
| B. | 13″ (33 cm) max. upper cabinet depth |
| C. | 30″ (76.2 cm) min. opening width |
| D. | For minimum clearance to top of cooktop, see NOTE*. |
| E. | 30 1/8″ (76.5 cm) min. opening width |
| F. | The shaded areas are recommended for installation of rigid gas pipe. |
| G. | 11″ (27.6 cm) |
| H. | 17″ (43.2 cm) |
| I. | 2″ (5.1 cm) |
| J. | 4 1/2″ (11.4 cm) |
| K. | 3″ (7.6 cm) min. clearance from both sides of range to side wall or other combustible material. |
| L. | Grounded outlet |
| M. | Cabinet door or hinges should not extend into the cutout. |
* NOTE: 24″ (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1/4″ (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015″ (0.4 mm) stainless steel, 0.024″ (0.6 mm) aluminum or 0.020″ (0.5 mm) copper.
30″ (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
What is important to know when installing a range hood or microwave hood combination?
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hoods combination instructions for dimensional clearances above the cooktop surface.
Can this range be installed next to combustible walls?
A freestanding range may be installed next to combustible walls with zero clearance.
How should the range be leveled after installation?
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
The range can be raised approximately 1″ (2.5 cm) by adjusting the leveling legs.
CLICK HERE TO DOWNLOAD WHIRLPOOL WFG720H0A (01) PDF MANUAL
