Free English VERTEX VITRAN VX10 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD VERTEX VITRAN VX10 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the main parts of the VERTEX VITRAN VX10 metal detector?
The VERTEX VITRAN VX10 package includes the following main parts:
• Main Unit with Armrest
• Extension Shaft
• Grip Lever (Clamp)
• Search Coil (V10)
• Headphones
• Charger
• Fixing Screw
How do I assemble the VERTEX VITRAN VX10?
To assemble your VERTEX VITRAN VX10, you need to extend the arm, attach the search coil, and connect the search coil cable.
Extending the Arm:
1. Move the grip lever (clamp) to the open position to freely adjust the arm’s length.
2. Pull the arm outward or push it inward to a comfortable length for use.
3. Move the lever back to the closed position and ensure the lock is securely fastened to prevent slipping.
Attaching the Search Coil:
1. Place the detector on a flat surface so the search coil is parallel to the ground. Position the arm’s end into the designated slot on the coil, ensuring the side holes of the arm align with the holes on the coil.
2. Insert the fixing screw through the aligned holes from the left side. Turn it clockwise until it is firmly secured. Ensure it is tight enough to hold the coil, but avoid over-tightening to prevent damage.
Connecting the Search Coil:
1. Locate the connector port on the coil. Align the white marks on both the plug and socket before inserting.
2. Gently insert the plug into the socket, pushing it in gradually with slight downward pressure.
3. Once the plug is partially inserted, rotate the locking nut while continuing to apply pressure until the plug is fully inserted. Tighten the locking nut securely for a stable connection.
What are the functions of the controls on the VERTEX VITRAN VX10?
| Control | Function |
|---|---|
| 1. Power On/Off | Press and hold for 3 seconds to turn the detector on or off. |
| 2. Confirmation Button (OK) | Used to confirm and enter the selected option. |
| 3. Back Button | Returns to the previous menu or cancels the current operation. |
| 4. Navigation Arrows | Navigate through the user interface and control search options. |
| 5. Tab Button | Switches to quick settings on the right side of the main interface and navigates between them. |
| 6. Settings Button | Pressing it once temporarily pauses the search. Pressing it again resumes the search. It also displays a white frame around search technologies or settings icons at the bottom of the main interface for selection. |
| 7. Handle Button | Press momentarily to recalibrate the device. Press and hold to switch to Pinpointer Mode for precise target localization. |
What are the technical specifications of the VERTEX VITRAN VX10?
| Technical Specifications | Details |
|---|---|
| Operating Principle | Signal analysis, data processing, and conversion into visual and audible results. |
| Processor Type | High Performance ARM CORTEX M7. |
| Display Type | 5-inch TFT color screen (800 x 480 WVGA, Resolution). |
| Battery | Built-in, 12.6V / 3500mAh – Lithium-ion. |
| Power Consumption | 600mA (average consumption). |
| Battery Life | More than 6 hours of continuous operation. |
| Charger | 30W PD / Type-C. |
| Detection Sound | Interactive frequency-based tone. |
| Control Sound | High-quality mono sound. |
| Vibration | Optional feature, can be enabled or disabled as per user preference. |
| Primary Search Tool | V10 search coil (20×30 cm – 7.9 x 11.8 inches). |
| Detector Weight (with Search Tool) | 2 kg. |
| Total Weight (with Accessories & Packaging) | 4.650 kg. |
| External Packaging Dimensions | 82 x 42 x 18 cm. |
| Operating Temperature | From 10°C to 60°C. |
| Storage Temperature | From 10°C to 80°C. |
| Detector Dimensions (Assembled, Without Shaft Extension) | 91 x 39 x 13.5 cm. |
How do I charge the battery of the VERTEX VITRAN VX10?
To charge your VERTEX VITRAN VX10, follow these steps:
• Use only the charger and cable provided with the detector.
• Connect the charger to an electrical outlet and then connect the charging cable to the designated port on the detector.
• When connected, a charging interface will appear on the screen, showing that charging is in progress and displaying the current battery percentage.
• The detector cannot be used while it is charging.
• If the battery becomes very low during operation, the detector will sound an alarm and then automatically stop.
How do I use the Quick Settings on the VERTEX VITRAN VX10?
You can access the Quick Settings on your VERTEX VITRAN VX10 by pressing the Tab button for rapid adjustments. Use the up and down arrow keys to change the value for each setting.
The available Quick Settings are:
1. General Sound: Adjusts the volume of the device’s operational sounds.
2. Search Sounds: Adjusts the volume of the signals emitted when a target is detected.
3. Vibration Mode: Turns the vibration feature on or off.
4. Brightness: Adjusts the screen brightness level.
5. Idle Mode: Adjusts settings related to power-saving when the device is idle.
Can you explain the main user interface of the VERTEX VITRAN VX10?
The main user interface of the VERTEX VITRAN VX10 displays the following information:
1. Search Coil Status: Shows if the coil is “Connected” and active, or “Disconnected” if it is not detected.
2. Battery Indicator: Displays the current battery level and charging status.
3. Graph Display: Visually represents the signal from detected targets.
4. Target ID: A large numeric value representing the type of metal detected.
5. Pinpointer Mode: An icon that appears when the handle button is pressed and held, indicating the mode is active for precise target location.
6. Turbo Mode: Activated before searching to enhance signal strength in pure, debris-free soil.
7. Iron Rejection: Allows the user to ignore signals from ferrous metals.
8. Ground Calibration: Used to determine the ground type before a search.
9. Sensitivity Indicator (SENSE): Adjusts sensitivity levels to match search conditions and reduce interference.
10. Gain Indicator (GAIN): Increases or decreases the transmitted signal strength.
11. Detector Settings: Accesses the main settings menu for customization.
How do I interpret the Graph Display and Target ID on the VERTEX VITRAN VX10?
Graph Display:
• Non-ferrous metals (like gold, silver, copper) appear as a yellow line above the zero signal strength line.
• Ferrous metals (like iron) appear as a red line below the zero line.
• Relevant controls are displayed below the graph for quick access.
Target ID (Target Identification):
• A green indicator in the center represents all types of metals.
• A red indicator on the right denotes ordinary or non-precious metals.
• A yellow indicator on the left signifies precious metals.
• The specific numeric metal type value is displayed prominently in the center of the interface.
How do I adjust the settings on the VERTEX VITRAN VX10?
You can customize your VERTEX VITRAN VX10 through the Device Settings menu. Navigate to the gear icon and press OK to enter.
Display Settings:
• Brightness: Adjust brightness levels using the up and down arrows.
• Sleep Mode: Enables automatic screen dimming to save power. Access this setting with the right arrow and adjust with the up and down arrows.
Sound Settings:
• General Sound: The detector emits sound signals during operation. This can be muted or adjusted using the up and down arrows.
• Vibration Mode: Accessible via the right arrow. Enable or disable vibration for alerts. Adjust with up and down arrows.
• Search Sound: The detector produces search signals. Access this with the right arrow and adjust volume levels with the up and down arrows.
How do I perform a factory reset on my VERTEX VITRAN VX10?
To restore all settings on your VERTEX VITRAN VX10 to their default values, navigate to the “Factory Reset” option within the Device Settings menu. When you select it, a confirmation message will appear: “Are You Sure?!”. Select “Yes” to proceed with the reset.
How can I view the system information of my VERTEX VITRAN VX10?
To view essential data for your VERTEX VITRAN VX10, go to the Device Settings menu and select “Device Info”. This screen will display the following:
• Serial Number
• Software Version
• Total Operating Hours
What is the operating principle of the VERTEX VITRAN VX10?
The VERTEX VITRAN VX10 uses Very Low Frequency (SFX) technology. Here is how it works:
1. It operates by transmitting electromagnetic waves from the search coil into the ground layers with minimal signal loss.
2. When these waves encounter a metallic target, the returning signal received by the coil is altered based on the metal’s type and composition.
3. Advanced digital filters process and refine these changes to extract a clean electrical signal.
4. The software processing unit analyzes this signal using mathematical operations to accurately determine the type of metal and estimate its depth.
What are some tips I should follow before searching with the VERTEX VITRAN VX10?
Before you begin a search with your VERTEX VITRAN VX10, follow these important tips:
• Keep metal objects away: Ensure that personal items like phones, watches, necklaces, and bracelets are kept at a safe distance from the search area to prevent signal interference and false readings.
• Avoid high-voltage lines and industrial areas: Stay away from power lines, industrial facilities, and large amounts of iron debris. If you must search in these areas, reduce the sensitivity level to minimize interference.
• Maintain distance between detectors: If multiple metal detectors are being used simultaneously, ensure there is a minimum distance of 100 meters between them to prevent signal interference.
What do the numeric target values mean on the VERTEX VITRAN VX10?
The following table shows the numeric values and associated target types for the VERTEX VITRAN VX10. Note that the value of a detected target can vary depending on metal type, alloy composition, and size.
| Numeric Value | Target Type |
|---|---|
| From -90 To 0 | Non-Precious Metals – Aluminum Foil – Tin Sheets |
| From 0 To 40 | Copper – Bronze – Precious Metal Alloys |
| From 40 To 75 | Gold – Gold Nuggets – Zinc – Precious Metal Alloys |
| From 75 To 90 | Chromium – Silver – Large Aluminum Pieces |
How do I set up and calibrate the VERTEX VITRAN VX10 for a search?
1. Detector Setup:
• Unlock the extension shaft, adjust it to your desired length, and relock it securely.
• Press and hold the power button for 3 seconds to turn on the detector, then select your desired settings.
2. Detector Calibration:
To ensure accuracy, perform calibration away from any external interference.
• Navigate to the ground calibration icon using the arrow keys and press OK to enter the calibration interface.
• Select the soil type (dry or wet), ensuring the area is free of metals, then press OK.
• The calibration interface will appear. Raise and lower the detector several times, keeping the search coil parallel to the ground.
• Maintain a coil height between 10 cm and 35 cm from the ground, as shown in the on-screen guide.
• Calibration takes 10 to 30 seconds. If the graph fluctuations on the screen remain low and close to the zero line, the coil is successfully calibrated.
• Once calibration is complete, a confirmation message will appear.
What is the correct search technique for the VERTEX VITRAN VX10?
3. Starting the Search:
• Press the Back button, then navigate to the Gain (Amplification) icon and press OK.
• Adjust Gain and Sensitivity using the up and down arrows according to the ground conditions.
• Press the Settings button to begin searching from the main interface, or press OK to search from the Graph or Target ID interface.
4. During the Search:
• Keep the search coil approximately 10 cm above the ground.
• Move the coil from side to side, keeping it parallel to the ground.
• Monitor the screen for target detection signals.
Note: If ground conditions change during the search, press the handle button briefly to initiate a quick recalibration.
5. Pinpointing the Target:
• When a target is detected, press and hold the handle button to activate Pinpoint Mode for precise location.
• Keep holding the button to monitor the data. When you release it, the interface returns to the previous search mode.
How do I use the wired headphones with the VERTEX VITRAN VX10?
The wired headphones for the VERTEX VITRAN VX10 are designed to provide a clear and precise listening experience.
Connection Method:
› Insert the headphone cable into the device’s audio port.
› Ensure the cable is securely connected for optimal sound quality.
› Use the device’s volume control buttons to adjust the sound level to your preference.
› Listen carefully to the audio signals during the search, as variations in sound indicate different detected targets.
Note: Always disconnect the headphones gently after use. Avoid pulling the cable forcefully to maintain its integrity.
What are some general tips and warnings for using the VERTEX VITRAN VX10?
Tips for Achieving Optimal Results:
• Avoid interference: Stay away from high-voltage power lines, electrical wiring, or other electronic detectors.
• Choose location carefully: Select search areas far from influencing factors like large metal objects and environmental fields.
• Update detector settings: Adjust sensitivity and balance settings according to the environment for optimal performance.
• Use the battery correctly: Fully charge the battery before use to prevent power interruptions.
Warnings for Ensuring Safety During Use:
• Avoid hazardous areas: Do not operate near flammable materials or close to high-voltage power lines.
• Be cautious of extreme weather: Refrain from using the detector in harsh conditions like heavy rain or excessively high temperatures.
• Carry the detector securely: Handle the detector properly to prevent it from falling or being damaged.
• Handle components with care: Do not disassemble or modify internal components without consulting technical support.
Detector Storage Conditions:
• Environment: Store the detector in a dry place away from humidity and extreme heat or cold.
• Power Off: Always switch off the detector completely before storing it.
• Protection: Keep the detector in its designated carrying case to protect it from dust and impact.
What safety information should I be aware of when using the VERTEX VITRAN VX10?
Please adhere to the following safety instructions for your VERTEX VITRAN VX10:
• The components are prone to damage from electrostatic discharge (ESD). It is recommended to discharge static electricity from your body by touching another metal object before handling the device.
• Do not assemble or operate the detector without first reading and understanding the user manual.
• Ensure all components are securely connected. Loose connections can cause malfunctions.
• Ensure the power outlet supplies the same voltage indicated on the charger before connecting it.
• Keep the detector away from moisture.
• Do not leave the detector in an environment with a temperature above 60°C (140°F).
Have the detector inspected at a service center in any of the following situations:
• A liquid has penetrated the detector.
• The detector has been exposed to high humidity.
• The detector does not operate properly or cannot be turned on as described in the user manual.
• The detector has fallen or sustained damage.
• There are visible signs of damage or deterioration on the detector.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD VERTEX VITRAN VX10 (01) PDF DOCUMENT