What parts are included with the VERTEX ADROIT?

The VERTEX ADROIT package includes the following parts:

The Device

Antenna

RMS Sensor

Battery

Headphones

Charger


How do I assemble the VERTEX ADROIT?

To assemble the VERTEX ADROIT, follow these steps:

1. Place the RMS sensor in its designated position by turning it clockwise.

2. The antenna is installed in the same manner.

To install or remove the battery:

1. To remove, press the release button and drag the battery down and away from the handle.

2. To install, slide the battery up into the handle until it clicks into place.


What are the main controls on the VERTEX ADROIT?

The main controls on the face of the VERTEX ADROIT are:

1. Confirmation (OK) / Power On/Off: Press and hold for several seconds to turn the device on or off. While the device is operating, use this button to confirm and select the desired option.

2. Tab: Used to navigate through the device’s user interface.

3. Back: Return to the previous menu or cancel the operation.

4. Control Arrows: Used to increase or decrease and control the system options.

Other controls include the Handle Button, External Speaker, Headphone Jack, and Battery Charging port.


What are the technical specifications of the VERTEX ADROIT?

Operating Principle Signal analysis, data processing, and conversion to visual and audio results
Display Type 2.8-inch color TFT screen with a resolution of 320 x 280 QVGA, 24-bit color depth.
Battery Independent unit – 4.2V lithium-ion, 3500mAh.
Power Consumption Average consumption of 280 mAh.
Battery Operating Hours More than 12 continuous hours (operating hours may vary depending on screen brightness, sound levels, and search operations).
Electric Charger 100-240V AC / Output power: 5V-1.5A.
Sound High-quality mono sound.
Languages Equipped with 6 languages.
Device Dimensions 21 x 12 x 8.5 cm.
Complete Device Weight 960 g.
Device Weight with Packaging 435 g.
External Packaging Dimensions 10 x 16 x 24 cm.
Operating Temperature From 10°C to 60°C (50°F to 140°F).
Storage Temperature From -10°C to 80°C (14°F to 176°F).

How do I charge the battery of the VERTEX ADROIT?

Follow these instructions for charging the VERTEX ADROIT battery:

• Use the charger and cable provided by the company (VERTEX).

• The battery can be charged both inside the device and independently.

• Connect the charger to the electrical outlet and then plug the charging cable into the designated place under the battery.

• When charging starts, the charging signal light turns red, and when charging is complete, it turns green.

• The device can be used temporarily while charging, but this increases the charging time.

During operation of the device, when the battery is very low, the device will sound an alarm and then automatically stop.


What are the main detection technologies available on the VERTEX ADROIT?

The VERTEX ADROIT features advanced detection technologies, which are accessible from the main interface:

1. RMS Technology: Multi-Response Search Technology.

2. ADRI Technology: Intelligent Dynamic Search Technology.

3. MDRI Technology: Targeted Search Technology with Pre-Specification.

You can also access the general settings from the main interface by navigating with the Tab key.


How do I change the settings on my VERTEX ADROIT?

Navigate through the settings using the Tab key and use the control arrows to adjust values. Press OK to confirm.

Languages: Select the desired language using the arrows and press OK. A confirmation message will appear; select Yes to install the chosen language.

Display (Brightness): Adjust the brightness level from 10% to 100% (max 450 nits) using the arrow keys.

Idle Mode: Adjust the automatic dimming of the brightness level to save energy. This time can be set to 15, 30, 45, 60, 75, 90, or 120 seconds, or it can be completely disabled.

General Sound: Adjust the volume of the startup tone, key sounds, and other sounds by changing the values using the arrow keys.

Search Sounds: Adjust the search sound level by changing the values using the arrow keys.

Vibration Mode: Select to enable or disable vibration using the arrow keys.

Factory Settings: This option restores all settings to their default values.


What information is shown in the “About the Device” screen on the VERTEX ADROIT?

The “About the Device” screen includes basic information about the device:

1. Serial Number

2. Software Version

3. Software Date

4. Electronic Board Version

5. Device Operating Hours (Life Time)


How does the RMS Technology work on the VERTEX ADROIT?

RMS (Multi-Response Search) Technology has two modes:

Active Search: This technology works by sending specialized frequencies to stimulate electrostatic fields that form around metals buried for long periods. The interaction between metals and the environment causes an accumulation of electrostatic charges, allowing the device to detect them. This system is used in open areas or deserts where radio transmission waves do not reach.

Passive Search: This technology works by detecting changes in the active electrostatic fields around metallic objects. This system allows for increased sensitivity and greater accuracy in locating metallic objects.


How do I use the RMS Technology on my VERTEX ADROIT?

First, install the RMS sensor and antenna as indicated. From the main interface, select RMS Technology.

For Active Search:

1. The RMS sensor must be installed in its designated position at the front of the device.

2. The transmitting antenna should be placed on the movable part.

For Passive Search:

1. Only the RMS sensor should be installed in its designated position.

2. Select what you wish to detect and press OK.

Starting the Search:

The detection will start immediately. Press the handle button in a location away from external influences and believed to be free of targets, so the device can begin automatic balancing. This can also be done manually with the arrows. Adjust sensitivity according to noise and external factors before walking. The device must be in a stable condition. Follow the target signal through the sound and screen indicators. The signal increases as you approach the target.

Note: When using the device in active search mode, the movement of the antenna does not indicate the direction of the target.


What do the indicators mean in RMS Technology mode on the VERTEX ADROIT?

1. Sensitivity Indicator: Adjust the sensitivity to a low value for general search and increase the number to locate the target when searching for specific objects.

2. Balance Indicator: It can be adjusted automatically using the handle button or manually using the arrows.

3. Signal Strength Indicator: The higher the indicator, the closer the target is. You can navigate between the balance and sensitivity settings using the Tab key.

Note: All external influences should be avoided, such as electric cables, high-voltage lines, mobile phone use, rings, and watches, as they may affect the accuracy of the results.


How do I use ADRI Technology on my VERTEX ADROIT?

For ADRI (Intelligent Dynamic Search) Technology, consider the following conditions for Active Search:

• Only the antenna should be installed.

• Hold the device properly, so the antenna is parallel to the ground.

• Orient the device towards the area to be explored.

• Start in a fixed position, without movement, for the first stage.

• Press the handle button to start searching immediately.

Search Process:

1. Hold the device and move towards the target search area. Wait for the signal indicated by the movement of the antenna.

2. When a target is detected, the device displays it on the screen with an interactive sound, then continues searching for all targets.

3. At the end of the search, the detected targets will appear. Navigate between them using the arrows. Press OK to begin tracking the desired target.

4. The device will emit an audible signal and show the starting point of the search.


How do I track a target using ADRI Technology on the VERTEX ADROIT?

1. Determine Direction: Manually rotate the antenna slowly, keeping the device’s position and angle the same, until a distinctive sound is heard and vibration is felt. This is the direction of the target. Rotate the device towards the target and press the handle button. Select the starting point (right or left) with the arrows and press OK.

2. Calculate Distance: An interactive arrow will appear, indicating you need to move 25 meters to the right or left, forming a 90-degree angle with the target direction. After walking 25 meters, hold the device and wait for the antenna reading.

• If the antenna detects the target, press the handle button. The distance to the target will be calculated, and a map of the area will be displayed. The device will then proceed to route tracking.

• If the antenna does not detect the target, the device will ask you to walk another 25 meters.

3. Route Tracking: Observe the target tracking indicators, sound alerts, and correction indicators. When the target is in the direction of the path, it appears at the center of the screen. If the antenna deviates, follow correction indicators. Walk until the antenna turns completely to the right or left. Stop and mark this as the first stop. Continue walking in the antenna’s direction until it turns completely again. Mark this as the second stop. The target is located at the center of the distance between these two stop points.


How do I measure the depth of a target with the VERTEX ADROIT using ADRI Technology?

After pinpointing the target location, move approximately 5 meters away from the target. Then, press the Accept (OK) button or the handle button. Wait until the depth determination is complete. The result will automatically appear on the screen, displaying:

1. Type of target.

2. Distance from the starting search point.

3. Depth.


What is MDRI Technology and what can it detect on the VERTEX ADROIT?

MDRI (Directed search technology with pre-localization) emits a frequency wave that activates the static electric field of a target. The antenna captures the reaction and orients itself toward the target. The device emits a sound that increases in speed as the antenna points toward the target.

Types of Targets: Tin, Iron, Bronze, Copper, Silver, Gold Nugget, Gold, Void, Water, Emerald, Diamond, Meteorite, Aluminum, Lead.

Distance: Up to 2500 meters.

Depth: Up to 25 meters (for metallic targets and gemstones). Up to 200 meters (for water).

Frequency shift: From 1% to 10% of the selected target’s frequency.

Note: It is necessary to confirm what has been selected before starting the search process.


How do I set up and start a search using MDRI Technology on the VERTEX ADROIT?

1. Make sure to install the antenna.

2. From the main menu, use the navigation key to select the MDRI technology and press Accept (OK).

3. Select the type of target you want to search for using the arrows.

4. Press the Tab key to move to the distance selection and choose the search distance.

5. Press the Tab key to move to the depth selection and choose the depth of the target.

6. Press the Tab key to move to the frequency shift selection (optional). It is recommended to leave it at 0 for a standard search.

7. Press the Tab key again, and a screen will appear to confirm the selected information before starting the search.

8. When you press the handle key, a message will appear to hold the device in the correct position (antenna parallel to the ground, arm in front of your chest). Press the handle key again when you are ready.

9. The user must walk southwards during the search, aligning with the Earth’s magnetic fields. The device will start emitting the signal.


How do I determine a target’s location using MDRI Technology on the VERTEX ADROIT?

There are two methods for determining the target location with MDRI Technology:

1. Line between two points method:

• During the walk, if the antenna turns to the extreme right or left, it means you have passed the target. Stop at that point, which is the first stopping point, and mark it.

• Turn back and wait for the antenna to stabilize. Walk in the opposite direction until the antenna turns again to the extreme right or left. This is the second stopping point.

• The target will be located at the midpoint between the first and second stopping points.

2. Square method:

• During the walk, when the antenna turns to the extreme right or left, stop and mark this as stop point 1.

• Turn in the direction of the antenna and walk until it turns again. This is stop point 2.

• Turn again towards the antenna and walk until it turns again. This is stop point 3.

• Turn once more towards the antenna and walk until it turns again. This is stop point 4.

• The target location is where lines drawn between stop point 1 & 3 and stop point 2 & 4 intersect.


What are some tips for achieving optimal results with the VERTEX ADROIT?

Avoid sources of interference: Stay away from high-voltage power lines, electrical wiring, or nearby electronic devices that may affect the accuracy of the results.

Choose the search location carefully: Ensure it is far from influencing factors such as metals and environmental fields to guarantee accurate results.

Update device settings: Ensure that sensitivity and balance settings are adjusted according to the surrounding environment for optimal performance.

Use the battery correctly: Fully charge the battery before use to prevent power interruptions during operations.


What are the safety warnings for using the VERTEX ADROIT?

Avoid hazardous areas: Do not operate the device near flammable materials or close to high-voltage power lines.

Be cautious of extreme weather: Refrain from using the device in harsh weather conditions, such as heavy rain or excessively high temperatures.

Carry the device securely: Always handle the device properly and securely to prevent it from falling or being damaged.

Handle components with care: Do not disassemble or modify the device’s internal components without consulting technical support.


What are the proper storage conditions for the VERTEX ADROIT?

Dry and moderate-temperature environments: Store the device in a dry place away from humidity and extreme heat or cold.

Ensure the device is fully powered off: Always switch off the device completely before storing it to avoid unnecessary power consumption.

Protect from dust and impact: Keep the device in its designated carrying case to prevent exposure to dust or damage during storage.


What are the key safety precautions I should take before operating the VERTEX ADROIT?

• Do not assemble or operate the device before reading and understanding the user manual.

• The components are susceptible to damage from static electricity discharge. It is recommended to discharge static electricity by touching a ground metal surface before starting work.

• Store the device in an environment free of negative charges when not in use.

• Keep the device away from moisture.

• Always turn off the device completely before storing it.

• Ensure the power outlet supplies the same voltage indicated on the charger before connecting it.

• Make sure all components of the device are securely connected. Loose connections may cause malfunctions.

• Hold the device firmly while it is in operation.

• Keep the user manual for future reference.


When should my VERTEX ADROIT be inspected at a service center?

In the event of any of the following situations, have the device inspected at a service center:

• A liquid has penetrated the device.

• The device has been exposed to high humidity.

• The device does not operate properly or cannot be turned on as described in the user manual.

• The device has fallen or sustained damage.

• There are visible signs of damage or deterioration on the device.

Also, do not leave the device in an environment with a temperature above 60°C (140°F), as this could damage the device.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD VERTEX ADROIT (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.