Free English VACZON VZA01W109A-BLE (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD VACZON VZA01W109A-BLE (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the important safety instructions for installing and using the VACZON VZA01W109A-BLE ceiling fan?

1. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount directly to a structural framing member or to an outlet box marked acceptable for fan support of 15.9kg (35 lbs). For outlet box mounting, use mounting screws provided with the outlet box.

2. To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

3. To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.

4. WARNING: To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

5. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. It is recommended that children be supervised to ensure that they are not using the appliance improperly.

6. WARNING: To reduce the risk of fire or electric shock or injury to persons, do not use replacement parts that have not been recommended by the manufacturer (e.g. parts made at home using a 3D printer).

7. Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

8. Before installing the fan, disconnect the power by removing fuses or turning off circuit breakers.

9. Make sure all electrical connections comply with local law and the national electrical code. Please hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring.

10. Make sure the installation site is roomy enough to allow fan blades to rotate. There is at least seven feet from the floor to fan blades’ tips.

11. If you are mounting the fan on a ceiling outlet box, please use a metal outlet box. Secure the box directly to the building structure. The outlet box and its support must be able to support the rotating fan (at least 35lbs). Do not use a plastic outlet box. Attach the mounting bracket using the ceiling outlet box’s hardware.

12. After installing the fan, make sure all the connections are secured so that the fan won’t fall.

13. Do not insert anything between fan blades while the fan is operating.

14. Turn the fan off and wait for it to stop before reversing fan’s rotating direction.

15. WARNING: To reduce the risk of electrical shock and personal injury, do not install the fan on a sloped ceiling and do not use this fan with any solid-state fan speed control device, or rheostat. You must install the outlet box using the two steel screws and lock washers coming with the fan.

16. All wiring must be in accordance with national and local electrical codes ANSI/NFPA70. If you are unfamiliar with wiring, use a qualified electrician.

17. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.

18. The splices after being made should be turned upward and pushed carefully up into the outlet box.

19. Instructions for supply connections: the white conductor of a fan identified as grounded conductor to be connected to a grounded conductor of power supply, the black conductor of fan identified as ungrounded conductor to be connected to an ungrounded conductor of power supply, the green conductor of fan identified for equipment grounding to be connected to an equipment-grounding conductor.

20. When mounted directly to the building structure, appliance installation shall not expose combustible material and do not install the appliance to a ceiling with combustible finish. The installation of the appliance can not leave the wood of the rafters or any thermal insulation exposed to the interior of the room.

21. To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing light kit.


What are the specifications for the VACZON VZA01W109A-BLE ceiling fan?

SKU# VZA01W109A-BLE
VZA01W109ABN-BLE
VZA01B109A-BLE
Voltage 120VAC 60Hz
Fan Blade Span 52″ Rated Wattage 53W (Fan 35W, Lamp 18W)
Maximum Airflow 3753CFM RPM 100-190rpm
Maximum Noise 45db(A) Number of rotating blades 5 blades

What do I need to check before installing the VACZON VZA01W109A-BLE ceiling fan?

Before installation, you will need the following tools (not included): a ladder, Phillips screwdriver, wire stripper, and a drill.

You must also check the following dimensions and angles:

Room Dimensions: There must be a minimum of 7 feet from the bottom edge of the fan blade to the floor, and a minimum of 30 inches from the blade tip to the nearest wall or obstruction.

Ceiling Angle: Make sure your room ceiling angle is less than 15 degrees.


How do I install the ceiling bracket for the VACZON VZA01W109A-BLE?

First, to avoid possible electrical shock, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location.

Option 1: Concrete Ceiling

Use the 2 provided mounting screws and washers when securing to an existing ceiling fan-rated outlet box. Make sure the outlet box is securely installed and is acceptable for fan support of 15.9kg (35 lbs) or less.

Option 2: Wood Ceiling

Use the 4 provided wood screws when securing to a support structure with an approved electrical outlet box. Drill 4 holes in the support structure to aid in securing the ceiling bracket.


How do I assemble the downrod for the VACZON VZA01W109A-BLE?

WARNING: FAN FALL HAZARD. ALWAYS tighten the setscrew with a screwdriver. DO NOT hand tighten the setscrew. CHECK the setscrew is tight using a screwdriver each time you change fan direction.

Step 1: Remove the pre-installed setscrews and downrod pin from the fan motor assembly.

Step 2: Insert the canopy, canopy cover, and coupling cover onto the downrod. Pass all the wires to one side of the horizontal bar in the downrod to prevent excessive wire tangling.

Step 3: Carefully slide the downrod into the yoke of the motor assembly. Align the holes in the downrod with the holes in the yoke. Carefully re-install the downrod pin and clip.

Step 4: Tighten the setscrew with a screwdriver.

Step 5: Put down the coupling cover over the yoke.


How do I move the downrod ball from the 6-inch downrod to the 10-inch downrod on my VACZON VZA01W109A-BLE?

The downrod ball comes pre-installed on the 6-inch downrod. To move it to the 10-inch downrod, follow these steps:

a. Loosen and remove the two screws on the downrod ball from the 6-inch downrod.

b. Lift the downrod upwards, then remove the horizontal bar, and detach the downrod ball from the 6-inch downrod.

c. Install the downrod ball onto the 10-inch downrod and securely insert the horizontal bar in its designated position.

d. Insert the first perforated long screw tightly, and then insert the second short screw tightly.


How do I hang and wire the VACZON VZA01W109A-BLE ceiling fan body?

Step 1: Hang the Fan

Place the downrod ball into the ceiling bracket. Make sure the downrod ball slot matches the inner lock on the bracket. Rotate the downrod until it is secured.

Step 2: Wire the Fan

WIRING MUST BE UP TO CODE. All wiring must be in accordance with national and local electrical codes. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.

a. Connect the wires (white to white, black to black) from the ceiling to the controller using wire nuts.

b. Connect the 4 grounding wires (green wires) coming from the ceiling, downrod, controller, and ceiling bracket using a wire nut.

c. Insert the motor wires and light wires into the controller.

d. Slide the controller between the mounting bracket and the top of the downrod. Use the canopy to place the excess wires.

Step 3: Install the Canopy

Install the canopy to the screws of the mounting bracket, tighten the screws, and cover with the canopy cover.


How do I assemble the blades on the VACZON VZA01W109A-BLE?

Insert the fan blade into the fan-motor assembly. Attach the blade to the fan blade bracket of the fan-motor assembly using the provided blade screws and washers. Tighten them firmly. Repeat for all 5 blades.


How do I assemble the light kit on the VACZON VZA01W109A-BLE?

Step 1: Remove the 3 screws from the ceiling fan body. Place the screws aside for later use.

Step 2: Connect the wires of the ceiling fan body with the light kit. Attach the light kit to the ceiling fan body using the 3 screws you removed earlier and tighten them firmly.


How do I assemble the light shade on the VACZON VZA01W109A-BLE?

Rotate the light shade clockwise to securely fasten it into place on the light kit.


What are the product dimensions of the VACZON VZA01W109A-BLE ceiling fan?

The dimensions of the assembled fan are as follows:

Fan Span: 52 in. (1320mm)

Canopy Diameter: 6.5 in. (165mm)

Motor Housing Diameter: 8.5 in. (215mm)

Height from Ceiling to bottom of Motor: 11.5 in. (292mm)

Height from Ceiling to bottom of Light Shade: 15 in. (382mm)

Downrod Dimensions: 1.04 in. diameter x 6 in. or 10 in. length (26.5mm x 150mm or 250mm)


What are the functions of the buttons on the remote control for the VACZON VZA01W109A-BLE?

Power Switch (ON/OFF): Press to turn the power ON/OFF. Within 5 seconds after power on, hold press to match code.

Light Switch & CCT Setting (K ON/OFF): Press to turn the light ON/OFF. Hold press for 2 seconds to change the Color Correlated Temperature (CCT) to 3000K/4000K/6500K.

Fan Speed Setting (+/- Fan icons): Press the downward fan icon to cycle fan speed from 1 to 6. Press the upward fan icon to cycle fan speed from 6 to 1.

Fan CCT Setting (+/- Light bulb icons): Press the ‘+’ icon for light dimmer up. Press the ‘-‘ icon for light dimmer down.

Forward and Reverse (REV): Press to change the airflow direction. Within 5 seconds after power on, hold press to clear code.

Timer Settings (1H/2H/4H/8H):

– Press once: fan auto off after 1hr

– Press twice: fan auto off after 2hr

– Press 3 times: fan auto off after 4hr

– Press 4 times: fan auto off after 8hr


How do I match the remote control code for the VACZON VZA01W109A-BLE?

Within 5 seconds of turning the main power on to the fan, hold press the Power Switch (ON/OFF) key on the remote. When you hear a buzzing sound, the code match is successful. If not, please repeat the above steps again.


How do I install the remote control holder for the VACZON VZA01W109A-BLE?

1. Use the two holes on the holder as a guide to drill two corresponding holes in a flat wall.

2. Insert the two expansion screws into the holes and make them level with the flat wall.

3. Align the two holes on the holder with the two holes on the wall. Insert the two screws into the holes and tighten them using a screwdriver.

4. Store your remote control in the holder.


How do I replace the batteries in the remote control for the VACZON VZA01W109A-BLE?

The remote uses one CR2032, 3-volt lithium battery.

NOTE: When new, open the battery cover to remove the insulation spacer before use.

1. Remove the screw from the battery cover on the remote control using a Phillips head screwdriver.

2. Pull up and remove the battery cover.

3. Remove the old battery and replace it with a new CR2032, 3V battery, ensuring correct polarity.

4. Install the battery cover removed earlier and secure it with the screw.


What is the ingestion hazard warning for the battery used in the VACZON VZA01W109A-BLE remote control?

WARNING INGESTION HAZARD: This product contains a button cell or coin battery.

• KEEP new and used batteries OUT OF REACH OF CHILDREN.

• DEATH or serious injury can occur if ingested.

• A swallowed button cell or coin battery can cause Internal Chemical Burns in as little as 2 hours.

• Seek immediate medical attention if a battery is suspected to be swallowed or inserted inside any part of the body.

Remove and immediately recycle or dispose of used batteries according to local regulations and keep away from children. Do NOT dispose of batteries in household trash or incinerate. Even used batteries may cause severe injury or death. Call a local poison control center for treatment information. The compatible battery type is CR2032, 3V. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep them away from children.


How do I set up and use the ‘FanLamp Pro’ app with the VACZON VZA01W109A-BLE ceiling fan?

Step 1: Scan the QR code in the manual, or search “FanLamp Pro” from the App Store or Google Play to download the app.

Step 2: Turn on the Bluetooth on your phone.

Step 3: In the app, add a device, name the fan light, and choose the room for your fan.

Step 4: Pair the code with the app.

a. Within 5 seconds of turning the fan’s power on, click the pairing button in the app. If the light flickers or you hear a beep, it means the fan and app have successfully paired. The APP Control Distance is within 65ft (20m).

b. If a new phone is paired successfully, the previous phone will automatically be unpaired.


What do the buttons in the ‘FanLamp Pro’ app do for the VACZON VZA01W109A-BLE?

Pairing Button: Initiates the pairing process with the fan.

Timer Setting Mode: Sets a timer for the fan to turn off.

Natural Wind Mode: Simulates a natural breeze.

Sleep Wind Mode: Provides a gentle breeze for sleeping.

Reverse Rotation: The fan rotates in reverse to distribute warm air throughout a room.

Forward Rotation: The fan rotates forward for cooling.

White light: Sets the light to a white color temperature.

Natural light: Sets the light to a natural color temperature.

Yellow light: Sets the light to a yellow color temperature.

Night light: Sets the light to 10% brightness.

Sliders/Controls:

– Adjust Fan Speed

– Adjust Light Brightness

– Adjust Light CCT (Color Temperature)

Switches:

– Power Switch (ON/OFF)

– Light Switch

– Fan Switch


How should I clean and maintain my VACZON VZA01W109A-BLE ceiling fan?

• Shut off the main power supply before you begin any maintenance task.

• DO NOT use water or a damp cloth to clean the fan.

• Cleaning products may damage the finishes.

Clean the motor housing and blades with a soft brush or lint-free cloth to avoid scratching the finish. At least twice each year, lower the canopy to check the downrod assembly and tighten all screws on the fan.


What should I do if my VACZON VZA01W109A-BLE fan doesn’t work?

• Make sure the power switch is on.

• Check the circuit breaker to ensure the power is turned on.

• Make sure the blades spin freely.

• Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram.


What should I do if my VACZON VZA01W109A-BLE fan is wobbling excessively?

• Make sure the blades are properly installed on the ceiling fan body.

• Turn the power off, support the fan carefully, and check that the downrod ball is properly seated.


What should I do if the remote control for my VACZON VZA01W109A-BLE is erratic?

Make sure the battery is installed correctly. If the command indicator light keeps flashing, this indicates a low battery. Install a fresh battery.


What should I do if the remote for my VACZON VZA01W109A-BLE only works when close to the fan?

Change the battery in the remote control.


What should I do if my VACZON VZA01W109A-BLE is making noise?

• Make sure the blades are properly installed.

• Check to see if any of the blades are cracked. If so, replace all of the blades.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD VACZON VZA01W109A-BLE (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.