Free English TOSHIBA RKP007Z (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD TOSHIBA RKP007Z (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What are the general safety and handling precautions for the TOSHIBA RKP007Z?

To ensure safe operation of the TOSHIBA RKP007Z, follow these guidelines:

Never disassemble, modify, or repair the Remote Keypad as it may cause electric shocks, fire, or injuries.

Do not put or insert foreign objects such as waste cable, bars, or wires into the device.

Do not splash water over the unit or touch it with wet hands.

Do not apply dropping shocks or other physical shocks, as this can result in damage or malfunction.

Never use the Remote Keypad with any device other than TOSVERT series inverters.


What should I do if the TOSHIBA RKP007Z exhibits abnormal behavior?

If you notice abnormalities such as smoke, unusual smells, a blank display, or abnormal noise, turn off the input power immediately. Operating the TOSHIBA RKP007Z under these conditions may lead to fire. Contact your sales or repair agency for assistance.


How should the TOSHIBA RKP007Z be disposed of?

Disposal of the TOSHIBA RKP007Z must be handled by a specialist in industrial waste disposal. Improper disposal may produce noxious gases and result in accidents. Collection, transport, and disposal must be performed by licensed “Industrial Waste Product Collectors and Transporters” or “Industrial Waste Disposal Persons” in accordance with local laws regarding cleaning and processing of waste materials.


What are the installation requirements and prohibitions for the TOSHIBA RKP007Z?

When installing the TOSHIBA RKP007Z, adhere to the following instructions:

Do not install or operate the unit if it is damaged or if any part is missing.

Do not connect a LAN or telephone modular cable to the Remote Keypad; use only the Toshiba-specified cable.

Do not pull on the cable or the connector, as this may cause damage.

Use an emergency stop device and an additional safety device with your system to prevent serious accidents in the event of a keypad malfunction.

Do not install the unit in any place subject to high vibrations, as it may fall and cause injury.


What accessories and optional parts are available for the TOSHIBA RKP007Z?

The TOSHIBA RKP007Z is shipped with the following standard accessories:

1. User’s manual: 1 copy

2. Key cover: 1 piece

3. Mounting screws (M3 x 10mm): 4 pieces (Tightening torque: 0.6 Nm)

Optional interconnection cables (sold separately) include:

CAB0071: 1 meter

CAB0073: 3 meters

CAB0075: 5 meters


What are the functions of the operation keys on the TOSHIBA RKP007Z?

Operation Key Function
[RUN] Starts operation (requires parameter setup to be effective).
[STOP / RESET] Stops operation. In the event of a trip, press twice to reset.
[▲], [▼] Used for setting parameters (Up or Down).
[MODE], [ENT] Functions the same as the “MODE” and “ENT” keys on the inverter itself.
[FWD / REV] Used for selecting forward run or reverse run. Function depends on the inverter series.
[LOC / REM] Used for switching between local and remote control. Function depends on the inverter series.

What are the technical specifications for the TOSHIBA RKP007Z?

Item Specification
Type form RKP007Z
Applicable models VF-FS1, VF-nC3, VF-S15, VF-AS3J
Communication protocol Modbus RTU
Baud rate 9600, 19200, 38400 bps (Automatic detection)
Parity Even, Odd, None (Automatic detection)
Operating Altitude Indoor operation at 3,000m or less
Ambient temperature -10 to 60 °C
Storage temperature -25 to 70 °C
Relative Humidity 20 to 93% (free from condensation and vapor)
Vibration 5.9m/s² (0.6G) or less (10 to 55 Hz)
Protection Class IP54 (when installed on a flat panel)

Note: When using the TOSHIBA RKP007Z with the VF-FS1 inverter, parameter f829 must be set to 1 (Modbus RTU).


What are the mounting specifications for the TOSHIBA RKP007Z?

The TOSHIBA RKP007Z should be mounted according to these dimensions and requirements:

Panel Cut Dimensions: A rectangular cutout of 54mm (height) x 34mm (width) is required, with an additional circular cutout of 28mm diameter centered for the connector.

Screw Hole Placement: Four holes with a 4.0mm diameter (4-Φ4.0) should be drilled. The horizontal distance between screw holes is 34mm, and the vertical distance is 54mm.

Applicable Board Thickness: The mounting surface should be less than 3mm thick.

The unit weighs approximately 39g and features a box color of RAL 7016 and a panel color of PANTONE 426C.


CLICK HERE TO DOWNLOAD TOSHIBA RKP007Z (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.