What is the purpose of the Mode Button (white button) on the TITAN SCR3?

The Mode (white) button’s functionality is to switch between 3 or 4 modes (depending on model) that show the performance of the water heater.


What does the Voltage mode show on the TITAN SCR3?

This is the default mode and shows the voltage being consumed and the percentage it represents from the total voltage. When the voltage is at 100% the water heater is working at full capacity. As that number starts to decrease the energy savings increases. Voltage is displayed in Volts (V).


What does the Current mode show on the TITAN SCR3?

The current mode shows the current being used and the percentage it represents from total current. Current is being displayed in Amps (A).


What does the Power mode show on the TITAN SCR3?

The power mode shows the amount of energy being consumed. It is the result of the voltage times the current being utilized. Power is being displayed in Kilowatts (KW).


What is the Red Button used for on the TITAN SCR3?

This button is used to increase the temperature of the water. Please note that the water has to be running through the unit in order to adjust the temperature.


What is the Blue Button used for on the TITAN SCR3?

This button is used to decrease the temperature of the water. Please note that the water has to be running through the unit in order to adjust the temperature.


What is an important consideration when selecting the temperature setting of the TITAN SCR3 thermostat?

Please note that safety and energy conservation are factors to be considered when selecting the water temperature setting of the water heater’s thermostat. The lower the setting the greater the savings in energy and operating costs.


What is the danger regarding the thermostat setting for households with children, disabled, or elderly persons using the TITAN SCR3?

Households with children, disabled, or elderly persons may require a 120° F or lower thermostat setting to prevent contact with “HOT” water.


What size copper pipes are the TITAN SCR3 units designed to be installed using?

These units are designed to be installed using copper pipes with 1/2″ or 3/4″ depending on the model number that is being installed.


What should be done before connecting the TITAN SCR3 unit to the copper pipes?

Always flush all the water lines before connecting the unit to the copper pipes.


What should be done after the TITAN SCR3 unit is installed?

After the unit is installed, open each hot water faucet slowly to allow the air to vent from the water heater and piping.


What should not be used on compression fittings when installing the TITAN SCR3?

Do not use teflon tape or plumbing paste on compression fittings.


What should be installed in both the inlet and the outlet of the TITAN SCR3 for ease of service?

For ease of service, install a shut-off valve in both the inlet and the outlet of the unit.


What should be used to secure the TITAN SCR3 unit to the wall?

Secure the unit to the wall utilizing only the brackets and compression fittings provided by Niagara Industries.


What must all plumbing work comply with when installing the TITAN SCR3?

All plumbing work must comply with State and Local plumbing codes.


What must be installed when using any type of plastic pipe like Pex or CPVC with the TITAN SCR3?

When using any type of plastic pipe like Pex or CPVC you MUST install 36″ of cooper pipe to both the inlet and outlet of the unit. DO NOT connect any plastic pipe directly to the unit. Also when using plastic pipes you MUST install a pressure relief valve on the inlet.


What should be done before connecting the TITAN SCR3 to the electrical supply?

Test the installation for leaks before connecting to the electrical supply.


What must be checked with a professional electrician for the TITAN SCR3 installation?

Check with a professional electrician for required breaker and wire gauge.


What type of fittings should be used with the TITAN SCR3?

Use only the compression fitting ring and nut provided with each unit as shown above. Compression fittings are designed exclusively for these units, do not use a different type of threaded coupling.


What must be done before beginning any work on the electric installation for the TITAN SCR3?

Before beginning any work on the electric installation, be sure that the main breaker panel switch is “OFF” to avoid any danger of electric shock.


When must electrical hook-up proceed for the TITAN SCR3?

All mounting and plumbing must be completed before proceeding with electrical hook-up.


What must all electrical work for the TITAN SCR3 comply with?

All electrical work must comply with national and applicable state and local electrical codes.


What is a result of failure to electrically ground the TITAN SCR3 unit?

As with any electric appliance, failure to electrically ground unit may result in serious injury.


What should the breaker for the TITAN SCR3 be sized based on?

The breaker should be of same size than the energy consumption of the model being installed.


What is an important step regarding connections before energizing the TITAN SCR3?

Make sure that all the connections are tight. DO NOT FORGET to install the ground wire to the main breaker panel.


How long should water circulate before energizing the TITAN SCR3?

Before you energize the unit, allow water to circulate during approximately 20 seconds to make sure the unit doesn’t work dry, which may damage the heating elements.


What should not be done with the shutoff valves closed when operating the TITAN SCR3?

Do not turn on the power with the shutoff valves closed.


Who should be contacted to diagnose any problem with the TITAN SCR3?

Do not attempt to repair or replace any part of the tankless water heater; a licensed qualified technician should be contacted to diagnose any problem.


In the absence of local codes, what code should be followed for the TITAN SCR3 installation?

The Titan tankless water heater must be installed in accordance with these instructions and local codes. In the absence of local codes, use the newer edition of the National Electric Code.


Where should the TITAN SCR3 water heater be located?

Locate the water heater in a clean dry area as near as practical to the area of greatest heated demand. DO NOT install the water heater in outdoor, unprotected areas.


What access must the TITAN SCR3 water heater have for servicing?

Also, the water heater must be installed in a visual area with easy access to the water shutoff valves and to the power disconnect box as required by Electrical and Plumbing codes.


What should be ensured regarding the shutoff valves before turning on the power to the TITAN SCR3?

Do not turn on the power with the shutoff valves in an off position.


What clearance is required from the top and bottom of the TITAN SCR3 unit?

A minimum of 12″ clearance must exist from the top of the unit to ceiling and from bottom to floor.


What voids the warranty on the TITAN SCR3 unit concerning its electronic mode or connection parts?

TAMPERING WITH THE UNITS ELECTRONIC MODE, BREAKING THE SEAL OR REMOVING CONNECTION PARTS WILL VOID YOUR WARRANTY.


What protection is required for the TITAN SCR3 as an electronic appliance?

AS ALL ELECTRONIC APPLIANCE THIS UNIT MUST BE PROTECTED FROM RAIN AND WEATHER CONDITIONS.


What must be done before servicing the TITAN SCR3?

WARNING: DISCONNECT FROM SUPPLY BEFORE SERVICING.


What must be done before turning on the electricity for the TITAN SCR3 according to the Important Notes?

Before turning on the electricity let the water run for 20 seconds through the unit.


What is a potential risk if excessive heat from soldering on copper pipes is near the TITAN SCR3?

Note that excessive heat from soldering on copper pipes near the heater may cause internal damage.


What should a user do if they have problems understanding the instructions for the TITAN SCR3 installation?

If you have problems understanding the instructions in this manual STOP and get help from a qualified professional or contact customer support.


What is the required wire gauge for the TITAN SCR3 installation?

The PDF shows the following wire gauges based on the model for the TITAN SCR3 series (Column labeled SCR3):

MODEL WIRE
N-10 10ga
N-42 12ga
N-64 10ga
N-75 8ga
N-85 8ga
N-100 6ga
N-120 6ga
N-160 6ga
N-180 8ga
N-210 6ga
N-270 6ga

What are the electrical specifications (Voltage, Breaker, Amps) for the TITAN SCR3 models?

The PDF provides the following electrical specifications for the TITAN SCR3 models:

MODEL VOLTS AMPS BREAKER
N-10 110 29 30
N-42 220 19 20
N-64 220 29 30
N-75 220 34 40
N-85 220 38 40
N-100 220 49 50
N-120 220 54 60
N-160 240 66 70
N-180 240 75 2×40
N-210 240 88 2×50
N-270 240 112 2×60

What is the maximum flow rate (MAXFLOW) for the TITAN SCR3 models?

The PDF shows the following maximum flow rates for the TITAN SCR3 models:

MODEL MAXFLOW
N-10 1.5 gpm
N-42 2 gpm
N-64 2.5 gpm
N-75 2.8 gpm
N-85 3.0 gpm
N-100 3.5 gpm
N-120 4.0 gpm
N-160 4.0 gpm
N-180 5.0 gpm
N-210 5.0 gpm
N-270 5.0 gpm

What is the temperature rise in degrees Fahrenheit for a TITAN SCR3 model N-64 operating at 2.0 gpm flow rate?

For the TITAN SCR3 model N-64, the temperature rise at 2.0 gpm flow rate is 26 deg.


What is the required voltage for the TITAN SCR3 model N-160?

The required voltage for the TITAN SCR3 model N-160 is 240.


What is the required breaker size for the TITAN SCR3 model N-180?

The required breaker size for the TITAN SCR3 model N-180 is 2×40.


What is the temperature rise for a TITAN SCR3 model N-270 operating at 1.5 gpm flow rate?

For the TITAN SCR3 model N-270, the temperature rise at 1.5 gpm flow rate is 118 deg.


What should the installer ensure regarding the screws and brackets when mounting the TITAN SCR3?

Make sure to only use the brackets and screws that are provided in the mounting kit. The use of longer screws may damage the unit and void your warranty.


What voltage is the TITAN SCR3 unit shown in the Installation Diagram for TITAN SCR3 SERIES operating at?

The installation diagram for the TITAN SCR3 SERIES indicates operation at 240 VAC 60Hz/50Hz.


What size inlet/outlet is indicated for the TITAN SCR3 in its installation diagram?

The installation diagram for the TITAN SCR3 SERIES shows a 1/2 Inlet Cold Water and a 1/2 Outlet Hot Water connection.


What is the required copper pipe length before and after the unit when using plastic pipe for the TITAN SCR3?

For cpvc, pex or any plastic pipe you MUST use at least 36″ of Copper Pipe before and after the unit and install a pressure relief Valve for the TITAN SCR3.