SURE COMFORT GF802D150 (01) Image

Free English SURE COMFORT GF802D150 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD SURE COMFORT GF802D150 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the key features of the SURE COMFORT GF802D150 furnace?

The SURE COMFORT GF802D150 two-stage downflow gas furnace is designed for installation in closets, alcoves, utility rooms, or attics and is certified by CSA International. Its features include:

• Patented heat exchanger, constructed of both stainless and aluminized steel for maximum corrosion resistance.

• Low profile “34 inch” [864 mm] design that is lighter, easier to handle, and leaves room for optional equipment.

• Left or right side gas and electric inlet connections with a quick, simple change.

• Direct spark ignition.

• Integrated control board with hookups for a humidifier and electronic air cleaner.

• Insulated blower compartment, a two-stage gas valve, and a specially designed two-speed draft inducer motor, making it one of the quietest furnaces on the market.

• Pre-painted galvanized steel cabinet.

• Grab-holes in doors to aid in easy door removal and replacement.

• Compatibility with single or two-stage thermostats. For optimal performance, a two-stage thermostat is recommended.

• A variety of cooling coils and plenums are available as optional accessories.


What is the Annual Fuel Utilization Efficiency (AFUE) rating for the SURE COMFORT GF802D150?

The SURE COMFORT GF802D150 has an Annual Fuel Utilization Efficiency (AFUE) of 80.0%. This rating falls in the mid-efficiency range, which spans from 82% to 88% on the ENERGUIDE scale.


What is included as standard equipment with the SURE COMFORT GF802D150?

The SURE COMFORT GF802D150 comes completely assembled and wired with the following standard equipment:

• 2-speed induced draft blower

• High and low pressure switches

• 2-stage redundant main gas control

• Blower compartment door safety switch

• Solid state time on/time off blower control

• Limit control

• Transformer

• Direct drive multi-speed blower motor

• Cooling/heating relay and transformer (40VA) ready for air conditioning applications

• Flame sensor diagnostics

• Fused-protection (secondary)

Note: A thermostat is not included as standard equipment. The furnace is not listed for use with fuels other than natural or L.P. (propane) gas.


What optional equipment is available for the SURE COMFORT GF802D150?

All models, including the SURE COMFORT GF802D150, can be converted by a qualified professional to use L.P. (propane) gas without changing burners. Factory-approved kits must be used for this conversion and may be ordered as optional accessories.

For L.P. (propane) operation, the direct spark ignition is a 100% lockout type.


Is the SURE COMFORT GF802D150 furnace approved for use in mobile homes?

No. The furnace is not approved or recommended for use in mobile homes.


What are the physical data and specifications for the SURE COMFORT GF802D150 furnace?

MODEL NUMBERS GF802D SERIES GF802D050 GF802D075 GF802D100 GF802D125 GF802D150
High Input-BTU-BTU/Hr [kW] ② 50,000 [15] 75,000 [22] 100,000 [29] 125,000 [37] 150,000 [44]
Heating Capacity-BTU/Hr [kW] ① 40,360 [12] 61,020 [18] 81,600 [24] 101,750 [29] 121,550 [35]
Low Input-BTU/Hr [kW] 35,000 [10] 52,500 [15] 70,000 [20] 87,500 [25] 105,000 [30]
Heating Capacity-BTU/Hr [kW] 28,000 [8] 41,600 [12] 56,000 [16] 70,000 [20] 84,000 [24]
Heating-Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .15 [.037] .20 [.05] .20 [.05]
Blower (D x W) [mm] 11 x 6 [279 x 152] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 11 x 10 [279 x 254] 11 x 10 [279 x 254]
Motor H.P.-[W] Speeds-Type 1/2 [373] 4-PSC 1/2 [373] 4-PSC 1/2 [373] 4-PSC 3/4 [559] 4-PSC 3/4 [559] 4-PSC
Motor Full Load Amps 6.8 7.1 7.1 9.5 9.5
Heating Speed-High Fire MED-LOW MED-HIGH MED-HIGH MED-HIGH MED-HIGH
Heating Speed-Low Fire LOW MED-LOW LOW LOW LOW
Cooling Speed HIGH HIGH HIGH HIGH HIGH
Cooling CFM @ .5″ [kPa] E.S.P. (Nominal) [L/s] 1200 [566] 1200 [566] 1200 [566] 2000 [944] 2000 [944]
Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F [°C] High Input 25-55 [13.9-30.6] 35-65 [19.4-36.1] 45-75 [25.0-41.7] 35-65 [19.4-36.1] 50-80 [27.8-44.4]
Temperature Rise Range °F [°C] Low Input 20-50 [11.1-27.8] 30-60 [16.7-33.0] 20-50 [11.1-27.8] 25-55 [13.9-30.6] 30-60 [16.7-33.3]
Max. Outlet Air Temp. °F [°C] 155 [68.3] 165 [78.3] 180 [82.2] 180 [82.2] 190 [87.7]
Standard Filter-In. [mm] (1) 14 x 20 [356 x 508] (2) 12 x 20 [306 x 508] (2) 12 x 20 [306 x 508] (2) 14 x 20 [356 x 508] (2) 14 x 20 [356 x 508]
Approx. Shipping Weight (Lbs.) [kg] 85 [39] 105 [48] 115 [52] 140 [63] 150 [68]
AFUE ① 80.0% 80.0% 80.0% 80.0% 80.0%

NOTES:

• All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2″ [12.7 mm] N.P.T.

① In accordance with D.O.E. test procedures.

② See Conversion Kit Index for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.


How can I identify the features of my SURE COMFORT GF802D150 from the model number?

The model number for the Downflow Models is broken down as follows:

GF: Gas Furnace

80: 80% Efficiency

2: 2 Stage

D: Downflow

Heating Input Designation (BTU/HR [kW]):

– 050 = 50,000 [15]

– 075 = 75,000 [22]

– 100 = 100,000 [28]

– 125 = 125,000 [37]

– 150 = 150,000 [44]

A: Variation

Variation Cabinet Type:

– S = Standard

– W = Wide Cabinet

Nominal Cooling Designation:

– 36 = 3 Tons

– 48 = 4 Tons

– 60 = 5 Tons

Note: [ ] Designates Metric Conversions.


What are the dimensions and required clearances for the SURE COMFORT GF802D150?

The following table provides the dimensions and clearance to combustible material for the SURE COMFORT GF802D series models.

MODEL GF802D Dimensions (inches) [mm] REDUCED CLEARANCES (IN.) [mm] SHIP. WGTS. (LBS.) [kg]
A B C D E LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT
050 14 [356] 1227/32 [326] 103/8 [264] ① 131/8 [333] 0 4 [102] ② 0 1 [25] 3 [76] 6 [152] ③ 85 [38.6]
075 171/2 [445] 1611/32 [415] 121/8 [308] ① 165/8 [422] 0 3 [76] ② 0 1 [25] 3 [76] 6 [152] ③ 105 [47.6]
100 171/2 [445] 1611/32 [415] 121/8 [308] ① 165/8 [422] 0 3 [76] ② 0 1 [25] 3 [76] 6 [152] ③ 115 [52.2]
125 241/2 [622] 2311/32 [593] 155/8 [397] ① 235/8 [600] 0 0 0 1 [25] 3 [76] 6 [152] ③ 140 [63.5]
150 241/2 [622] 2311/32 [593] 155/8 [397] ① 235/8 [600] 0 0 0 1 [25] 3 [76] 6 [152] ③ 150 [68]

NOTES:

① May require a 3″ [76 mm] to 4″ [102 mm] or 3″ [76 mm] to 5″ [127 mm] adapter.

② May be 0″ [0 mm] with type B vent.

③ May be 1″ [25 mm] with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.


What is the blower performance data for the SURE COMFORT GF802D150?

The following table shows the CFM [L/s] Air Delivery at various external static pressures for the SURE COMFORT GF802D series.

MODEL NUMBER GF802D SERIES BLOWER SIZE [mm] MOTOR H.P. [W] BLOWER SPEED .1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17]
050 11 x 6 [279 x 152] 1/2 [373] LOW 655 [309] 630 [297] 600 [283] 565 [266] 532 [251] 500 [236] 467 [220]
MED-LO 975 [460] 943 [445] 915 [432] 886 [418] 852 [402] 813 [383] 770 [363]
MED-HI 1180 [557] 1140 [538] 1105 [521] 1067 [503] 1027 [484] 980 [462] 924 [436]
HIGH 1335 [630] 1290 [608] 1250 [590] 1202 [567] 1157 [546] 1110 [524] 1060 [500]
075 11 x 7 [279 x 178] 1/2 [373] LOW 910 [429] 887 [418] 863 [407] 839 [396] 814 [384] 776 [366] 738 [348]
MED-LO 1074 [507] 1054 [497] 1034 [488] 1007 [475] 979 [462] 944 [455] 908 [428]
MED-HI 1229 [580] 1207 [569] 1184 [558] 1159 [547] 1134 [535] 1099 [518] 1063 [501]
HIGH 1409 [665] 1385 [653] 1361 [642] 1329 [627] 1297 [612] 1260 [594] 1223 [577]
100 11 x 7 [279 x 178] 1/2 [373] LOW 895 [422] 874 [412] 852 [402] 825 [389] 798 [376] 766 [362] 734 [346]
MED-LO 1052 [496] 1033 [487] 1013 [478] 991 [467] 968 [457] 930 [439] 891 [420]
MED-HI 1238 [584] 1217 [574] 1196 [564] 1169 [551] 1143 [539] 1094 [516] 1044 [492]
HIGH 1383 [652] 1366 [644] 1348 [636] 1317 [621] 1286 [607] 1245 [587] 1203 [567]
125 11 x 10 [279 x 254] 3/4 [559] LOW 1315 [620] 1292 [609] 1269 [599] 1250 [590] 1231 [581] 1194 [563] 1157 [546]
MED-LO 1618 [763] 1597 [753] 1576 [743] 1552 [732] 1528 [721] 1486 [701] 1443 [681]
MED-HI 2065 [974] 2025 [956] 1984 [936] 1938 [915] 1891 [892] 1824 [861] 1756 [829]
HIGH 2275 [1074] 2219 [1047] 2163 [1021] 2103 [992] 2042 [964] 1982 [935] 1921 [907]
150 11 x 10 [279 x 254] 3/4 [559] LOW 1300 [614] 1280 [604] 1230 [580] 1205 [569] 1170 [552] 1115 [526] 1030 [486]
MED-LO 1675 [791] 1650 [779] 1620 [765] 1570 [741] 1545 [729] 1485 [701] 1425 [673]
MED-HI 2105 [993] 2075 [979] 2035 [960] 1990 [939] 1955 [923] 1900 [897] 1815 [857]
HIGH 2340 [1104] 2290 [1081] 2215 [1045] 2145 [1012] 2080 [982] 1995 [942]

NOTES:

• ⊗ Not to be used as a low stage heating speed.

• Data compiled with factory filters installed.

• Factory rated to 0.5″ W.C.


What are the requirements for installing a SURE COMFORT GF802D150 on a combustible floor?

The unit design is certified for installation on a non-combustible floor. A special factory-supplied combustible floor sub-base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage, and personal injury.

The dimensions for the required combustible floor base are listed below:

COMBUSTIBLE FLOOR BASE USE WITH FURNACE SIZES A IN. [mm] B IN. [mm] C IN. [mm]
RXGC-B14 050 141/2 [368] 131/4 [337] 111/4 [286]
RXGC-B17 075, 100 18 [457] 163/4 [425] 143/4 [451]
RXGC-B24 125, 150 25 [635] 233/4 [603] 213/4 [552]

Are there any special kits for using the SURE COMFORT GF802D150 with a heat pump?

Yes, the RXPF-F01 and F02 Fossil Fuel Kits are for use with Sure Comfort™ Heat Pumps and warm air furnaces. The RXPF-F02 model meets TVA requirements.


What are the requirements for high altitude installation of the SURE COMFORT GF802D150?

For high altitude conversion, see the Installation Instructions for more information. Always follow National Fuel Gas Code (NFGC) guidelines when converting furnaces for high altitudes.


What filter rack accessory is available for the SURE COMFORT GF802D150?

The RXGF-CC* Filter Rack is available for downflow top return mount. Filter racks are shipped without filters.

The required filter sizes based on furnace width and input are listed below:

FURNACE WIDTH IN. [mm] INPUT BTUH [kW] SIZE IN. [mm] QUANTITY
14 [356] 45 [13.19] & 50 [14.65] 14 [356] x 20 [508] 1
171/2 [445] 67 [19.64], 75 [21.98] & 100 [29.31] 12 [305] x 20 [508] 1
21 [533] 100 [29.31] 12 [305] x 20 [508] 2
241/2 [622] 125 [36.63] & 150 [44.0] 14 [356] x 20 [508] 2

What should I do before starting the installation of the SURE COMFORT GF802D150?

Before proceeding with installation, refer to the installation instructions packaged with the model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SURE COMFORT GF802D150 (01) PDF DOCUMENT