What are the key features of the SURE COMFORT GF802D050 furnace?

The SURE COMFORT GF802D050 Two Stage Downflow Gas Furnace has the following features:

• Patented heat exchanger, constructed of both stainless and aluminized steel for the maximum in corrosion resistance.

• Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves room for optional equipment.

• Left or right side gas and electric inlet connections with quick, simple change.

• Direct spark ignition.

• Integrated control board with humidifier and electronic air cleaner hookups.

• Insulated blower compartment, a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the market today.

• Pre-paint galvanized steel cabinet.

• Grab-holes in doors to aid in easy door removal and replacement.

• Compatible with single or two-stage thermostat. (For optimal performance, two-stage thermostat recommended.)


What is included as standard equipment with the SURE COMFORT GF802D050?

The SURE COMFORT GF802D050 is completely assembled and wired and includes the following standard equipment:

• 2 speed induced draft blower

• High and low pressure switches

• 2 stage redundant main gas control

• Blower compartment door safety switch

• Solid state time on/time off blower control

• Limit control

• Transformer

• Direct drive multi-speed blower motor

• Cooling/heating relay and transformer (40VA) ready for air conditioning applications

• Flame sensor diagnostics

• Fused-protection (secondary)

Please note that a thermostat is not included as standard equipment. The furnace is not listed for use with fuels other than natural or L.P. (propane) gas.


Can the SURE COMFORT GF802D050 be converted to use L.P. (propane) gas?

Yes, all models in the GF802D series, including the SURE COMFORT GF802D050, can be converted by a qualified professional or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used for the conversion and can be ordered as optional accessories. For both natural and L.P. (propane) gas models, the direct spark ignition is a 100% lockout type.


Is the SURE COMFORT GF802D050 approved for use in mobile homes?

No, the SURE COMFORT GF802D050 furnace is not approved or recommended for use in mobile homes.


What are the physical data and specifications for the SURE COMFORT GF802D050 model?

SpecificationGF802D050
High Input-BTU/Hr [kW]50,000 [15]
Heating Capacity-BTU/Hr [kW]40,360 [12]
Low Input-BTU/Hr [kW]35,000 [10]
Heating Capacity-BTU/Hr [kW]28,000 [8]
Heating-Ext. Static Pressure [kPa].10 [.025]
Blower (D x W) [mm]11 x 6 [279 x 152]
Motor H.P.-[W]1/2 [373]
Speeds-Type4-PSC
Motor Full Load Amps6.8
Heating Speed-High FireMED-LOW
Heating Speed-Low FireLOW
Cooling SpeedHIGH
Cooling CFM @ .5″ [kPa] E.S.P. (Nominal) [L/s]1200 [566]
Max. E.S.P. (In. W.C.) [kPa]0.5 [.12]
Temperature Rise Range °F [°C] High Input25-55 [13.9-30.6]
Temperature Rise Range °F [°C] Low Input20-50 [11.1-27.8]
Max. Outlet Air Temp. °F [°C]155 [68.3]
Standard Filter-In. [mm](1) 14 x 20 [356 x 508]
Approx. Shipping Weight (Lbs.) [kg]85 [39]
AFUE80.0%

NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2″ [12.7 mm] N.P.T. AFUE is in accordance with D.O.E. test procedures. For high altitude derate, refer to furnace installation instructions.


How can the model number for the SURE COMFORT GF802D series be identified?

The model number provides details about the furnace. For example, in GF802D050AS36:

GF = Gas Furnace

80 = 80% Efficiency

2 = 2 Stage

D = Downflow

050 = Heating Input Designation (50,000 BTU/HR)

A = Variation

S = Variation (S = Standard Cabinet, W = Wide Cabinet)

36 = Nominal Cooling Designation (e.g., 36 = 3 Tons, 48 = 4 Tons, 60 = 5 Tons)


What are the dimensions and required clearances for the SURE COMFORT GF802D050?

The following are the dimensions and clearances to combustible materials for the SURE COMFORT GF802D050 model.

Dimensions (inches) [mm]:

  • A: 14 [356]
  • B: 12 27/32 [326]
  • C: 10 3/8 [264]
  • D: –
  • E: 13 1/8 [333]

Reduced Clearances (inches) [mm]:

LocationClearance
LEFT SIDE0
RIGHT SIDE4 [102]
BACK0
TOP1 [25]
FRONT3 [76]
VENT6 [152]

Shipping Weight: 85 LBS. [38.6 kg]

NOTES:

① May require a 3″ [76 mm] to 4″ [102 mm] or 3″ [76 mm] to 5″ [127 mm] adapter.

② May be 0″ [0 mm] with type B vent.

③ May be 1″ [25 mm] with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.


What is the blower performance data for the SURE COMFORT GF802D050?

The blower performance data for the SURE COMFORT GF802D050, which has an 11 x 6 [279 x 152 mm] blower and a 1/2 H.P. [373 W] motor, is as follows:

BLOWER SPEED EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN – CFM [L/s] AIR DELIVERY
.1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17]
LOW 655 [309] 630 [297] 600 [283] 565 [266] 532 [251] 500 [236] 467 [220]
MED-LO 975 [460] 943 [445] 915 [432] 886 [418] 852 [402] 813 [383] 770 [363]
MED-HI 1180 [557] 1140 [538] 1105 [521] 1067 [503] 1027 [484] 980 [462] 924 [436]
HIGH 1335 [630] 1290 [608] 1250 [590] 1202 [567] 1157 [546] 1110 [524] 1060 [500]

NOTES: Data compiled with factory filters installed. Factory rated to 0.5″ W.C. E = Standard, N = NOx Models.


What is required if installing the SURE COMFORT GF802D050 on a combustible floor?

The unit design is certified for installation on non-combustible floors only. A special factory-supplied combustible floor sub-base (Model RXGC-B14) is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage, and personal injury.

The dimensions for the RXGC-B14 combustible floor base are:

Dimension A14 1/2 in. [368 mm]
Dimension B13 1/4 in. [337 mm]
Dimension C11 1/4 in. [286 mm]

What is the RXGF-CC* Filter Rack accessory for the SURE COMFORT GF802D050?

The RXGF-CC* is a filter rack accessory for a downflow top return mount configuration. For the SURE COMFORT GF802D050 with a 14-inch [356 mm] furnace width and an input of 50 kBTU [14.65 kW], one 14 [356] x 20 [508] inch [mm] filter is required. Note that filter racks are shipped without filters.


What should be done for high altitude installations of the SURE COMFORT GF802D050?

For high altitude conversion, refer to the installation instructions for more information. Always follow National Fuel Gas Code (NFGC) guidelines when converting furnaces for high altitudes.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SURE COMFORT GF802D050 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.