Free English PENTAIR SHURFLO 4728 (01) PDF Document. Free English PENTAIR SHURFLO 4728 (01) PDF User Guide. Free English PENTAIR SHURFLO 4728 (01) PDF User Manual. Free English PENTAIR SHURFLO 4728 (01) PDF Owner Guide. Free English PENTAIR SHURFLO 4728 (01) PDF Owner Manual. Free English PENTAIR SHURFLO 4728 (01) PDF Reference Guide. Free English PENTAIR SHURFLO 4728 (01) PDF Instruction Guide. Free English PENTAIR SHURFLO 4728 (01) PDF Reference Manual. Free English PENTAIR SHURFLO 4728 (01) PDF Instruction Manual. Free English PENTAIR SHURFLO 4728 (01) PDF Operating Instructions.
CLICK HERE TO DOWNLOAD PENTAIR SHURFLO 4728 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What does “Intermittent Duty” mean for the PENTAIR SHURFLO 4728 pump?
“Intermittent Duty” is defined as: operated and/or frequently started within a period of time that would NOT cause the motor to reach its maximum thermal limits. Once the maximum thermal limit is obtained, the motor must be allowed to return to ambient temperature before resuming operation.
What safety precautions should be taken when using the PENTAIR SHURFLO 4728 pump with flammable liquids or in explosive environments?
DO NOT use the PENTAIR SHURFLO 4728 to pump flammable liquids. Never operate the pump in an explosive environment. Arcing from the motor brushes, switch or excessive heat from an improperly cycled motor may cause an explosion.
What should I know about fluid compatibility when using the PENTAIR SHURFLO 4728 pump?
DO NOT assume fluid compatibility. If the fluid is improperly matched to the pumps’ elastomers, a leak may occur. Pumps used to transfer hazardous or hot (max. temperature 120°F [49°C]) chemicals must be in a vented area to guard against the possibility of injury due to harmful or explosive liquid/vapors.
What are the operational guidelines regarding pressure and heat for the PENTAIR SHURFLO 4728 pump?
DO NOT operate the pump at pressures which cause the motor to exceed the amperes rating indicated on the name plate. Various pump models are equipped with thermal breakers to interrupt operation due to excessive heat. Once the temperature of the motor is within proper limits it will automatically reset, and the pump will start operation without warning.
How should I mount the PENTAIR SHURFLO 4728 pump?
The 4728 series pumps are self-priming. The pump should be located in an area that is dry and provides adequate ventilation. If mounted within an enclosure, provisions to cool the motor may be necessary. Heat sinks which attach to the motor are available from SHURFLO if increased heat dissipation is necessary.
The pump may be mounted in any position. However, if mounting the pump vertically the pump head should be in the down position so that in the event of a leak, fluid will not enter the motor. DO NOT compress the feet, doing so will increase vibration and noise.
What is the caution regarding the mounting location for the PENTAIR SHURFLO 4728 motor?
DO NOT locate the motor near low temperature plastics or combustible materials. The surface temperature of the motor may exceed 250°F [120°C].
What are the plumbing requirements for the PENTAIR SHURFLO 4728 pump?
Flexible high pressure tubing compatible with the fluid should be used to connect the inlet/outlet ports. Tubing should be at least 1/2″ [13 mm]. Restrictions on the inlet may cause vacuum levels to reach the fluid vapor pressure, causing cavitation, degassing, vapor lock, noise, and a loss in performance. Inlet pressure must not exceed 30 psi [2.1 bar] maximum. Installation of a 50 mesh strainer is recommended to prevent foreign debris from entering the pump. If a check valve is installed in the plumbing, it must have a cracking pressure of no more than 2 psi [.14 bar].
What are the electrical wiring requirements for the PENTAIR SHURFLO 4728 pump?
Electrical wiring should be performed by a qualified electrician, in accordance with all local electrical codes. The pump should be on a dedicated (individual) circuit, controlled with a switch (double pole VAC U.L./C-UL certified) rated at or above the fuse ampere indicated by the pump motor label. All 115 VAC and 230 VAC pump motors and systems MUST be grounded per local and state electrical codes. For the pump to meet U.L./C-UL requirements the circuit MUST be protected with a slow-blow fuse (U.L./C-UL certified) or equivalent circuit breaker as indicated on the motor label. Use an approved wire of the size specified or heavier.
What safety precautions should be taken to prevent electrical shock with the PENTAIR SHURFLO 4728 pump?
To prevent electrical shock, disconnect power before initiating any work. In the case of pump failure, the motor housing and/or the pumped fluid may carry high voltage to components normally considered safe.
What is the recommended wire size for the PENTAIR SHURFLO 4728 pump based on distance?
The minimum wire size is for a 10% voltage drop on a 12VDC, 15 Amp Circuit. Length is the distance from the power source to pump and back to ground.
| Ft. [m] | AWG [mm²] |
|---|---|
| 0-25 [0-7.6] | 16 [1.3] |
| 25-50 [7.6-15.2] | 14 [2.1] |
| 50-70 [15.2-21.3] | 12 [3.3] |
| 70-110 [21.3-33.5] | 10 [5.3] |
How can I obtain repair kits for the PENTAIR SHURFLO 4728 pump?
Kits are readily available to repair standard 4728 series pumps. Repair kits include simple illustrated instructions allowing easy installation. To insure that the correct kit is received the model numbered and all name plate data must be included with the order.
What are the part numbers for the PENTAIR SHURFLO 4728 service kits?
| ITEM | DESCRIPTION | PART NUMBER |
|---|---|---|
| 1 | Upper Assembly | 94-800-31 |
| 2 | Valve Assembly | 94-800-01 |
| 3 | Drive Assembly | 94-800-25 |
| 4 | Motor/Gasket | 94-71-007-07 |
| 1, 2, 3 | Pump Head | 94-800-30 |
| Not Shown | Check Valve | 94-800-03 |