What are the key safety instructions for the PARKER HYPERSEP SFH019P-097P?

When operating the PARKER HYPERSEP SFH019P-097P, please adhere to the following safety instructions:

• Do not exceed the design limits specified on the data plate.

• All compressed air/nitrogen circuits should include appropriate safety devices according to government and industry standards. The end user is responsible for installing these devices.

• Before starting any maintenance, ensure that the compressed air/nitrogen circuit is not under pressure.

• Only use the water separator for separating water from compressed air/nitrogen.

• Tampering, modification, or replacement of any parts by unauthorized personnel or improper use will invalidate the warranty.

• The user is solely responsible for making the final selection of the appropriate water separator and ensuring all performance, maintenance, and safety requirements are met.


How should I transport and handle the PARKER HYPERSEP SFH019P-097P?

• Do not store or transport the PARKER HYPERSEP SFH019P-097P in an unenclosed environment.

• Protect the water separator from impact to prevent damage.

• In the event of damage during transportation, handling, or installation, do not operate the water separator and replace it immediately.


What should I do upon receiving my PARKER HYPERSEP SFH019P-097P?

As soon as you receive the PARKER HYPERSEP SFH019P-097P, check its condition. If you notice any damage, inform the carrier immediately. Do not install or operate the damaged water separator; replace it immediately.


What are the installation guidelines for the PARKER HYPERSEP SFH019P-097P?

The PARKER HYPERSEP SFH019P-097P is typically installed on the compressed air/nitrogen outlet of aftercoolers or any other point where condensate needs to be separated.

• Do not install the water separator in an unenclosed environment. Install it in a ventilated area, away from heat sources and flammable materials.

• Support the water separator on suitable mountings to avoid stressing the inlet and outlet piping. No external loads are allowed on the inlet or outlet connection.

• Install one or more safety valves as necessary on the compressed air/nitrogen circuit to ensure that the maximum pressure of the water separator is never exceeded. The user must ensure the installation of safety valves complies with all applicable government and industry standards.

• If the circuit is subject to vibrations or pulsations, use appropriate dampers to connect the water separator.

• Ensure the compressed air/nitrogen does not contain corrosive gases. Take particular care in environments with high levels of Sulphur, Ammonia, Chlorine, and in marine applications.

• Take care to prevent accidental contact and burns when the unit is subject to temperatures exceeding 40°C.

• Install the water separator so that the compressed air/nitrogen flows in the direction indicated by the labels on the unit.

• Use appropriate industry standard counter flanges and gaskets to connect piping.

• Install an appropriate condensate drain. Note that carbon steel materials are subject to rusting. Ensure the condensate drain can remove rust particles from the separator with the condensate.

• Make sure that condensate drains can be visually checked for correct flow and are properly maintained.

• The water separator should not be subject to frequent pressure cycling exceeding 500 cycles from 0 to nominal pressure over its lifetime. Consider using a compressed air/nitrogen receiver to help avoid this.


How do I operate and maintain the PARKER HYPERSEP SFH019P-097P?

• Ensure that the water separator is properly sized for the compressed air/nitrogen flow, pressure, and temperature.

• Verify that the condensate collected within the water separator is being completely drained.

• Verify corrosion of the water separator periodically, at least once per year, by measuring its thickness. The thickness must not be less than the minimum values shown in the specification table.

• **IMPORTANT:** If the water separator’s thickness falls below the minimum level, it must be immediately removed from service and replaced.

• **IMPORTANT:** Welding, grinding, or any other modification is strictly forbidden and will invalidate the warranty.


How should I perform an ultrasonic thickness measurement on the PARKER HYPERSEP SFH019P-097P?

• It is recommended to contact qualified personnel certified by a third-party organization according to EN 14127:2011 requirements.

• An ultrasonic thickness tester suitable for use with painted surfaces should be used.

• Compare all measured results to the minimum values indicated in the table below. Measured results should be documented and saved.

• Separators with wall thicknesses less than the minimum values given should immediately be removed from service and replaced.

• Repeat the measurements at least every 12 months, measuring at the same positions on the water separator. Increase the frequency of measurement if the values are nearing the minimums.


What are the minimum thickness specifications for the PARKER HYPERSEP SFH019P-097P (High pressure models)?

Minimum thickness (mm) (High pressure)
Model Diameter Shell End Cap
Nominal thickness Minimum thickness Nominal thickness Minimum thickness
SFH019P 168.3 5 4.4 5 4.6
SFH029P 193.7 5.6 4.9 5 4.6
SFH037P 244.5 6.3 5.5 5 4.6
SFH066P 273 6.3 5.5 5 4.6
SFH088P 323.9 8 7.6 5 4.6
SFH097P 323.9 8 7.6 5 4.6

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD PARKER HYPERSEP SFH019P-097P (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.