What are the key safety instructions for the PARKER HYPERSEP SFH019N-550N?

To ensure safe operation of your PARKER HYPERSEP SFH019N-550N, please adhere to the following safety instructions:

• Keep the user manual with the water separator throughout its entire service life.

• Do not exceed the design limits specified on the data plate.

• Ensure all compressed air/nitrogen circuits include appropriate safety devices according to government and industry standards. The end user is responsible for installing these devices.

• Before starting any maintenance, make sure the compressed air/nitrogen circuit is not under pressure.

• Use the water separator only for separating water from compressed air/nitrogen.

• The user is solely responsible for the final selection of the appropriate water separator and ensuring all performance, maintenance, and safety requirements are met.

• Do not tamper with, modify, or replace any parts of the water separator with unauthorized personnel. Improper use will void the warranty.

• The manufacturer is not liable for damage due to operator negligence or non-compliance with the instructions in this manual.

• The user must select and properly maintain a condensate drain to ensure complete drainage from the water separator under all conditions.


How should I transport and handle the PARKER HYPERSEP SFH019N-550N?

• Do not store or transport the PARKER HYPERSEP SFH019N-550N in an unenclosed environment.

• Protect the water separator from impact to prevent damage.

• If any damage occurs during transportation, handling, or installation, do not operate the water separator. Replace it immediately.


What should I do upon receiving my PARKER HYPERSEP SFH019N-550N?

As soon as you receive the PARKER HYPERSEP SFH019N-550N, check its condition. If you notice any damage, inform the carrier immediately. Do not install or operate the damaged water separator; it must be replaced immediately.


What are the installation requirements for the PARKER HYPERSEP SFH019N-550N?

The PARKER HYPERSEP SFH019N-550N is typically installed on the compressed air/nitrogen outlet of aftercoolers or any other point where condensate needs to be separated.

• Do not install the water separator in an unenclosed environment. Install it in a ventilated area, away from heat sources and flammable materials.

• Support the water separator on suitable mountings to avoid stressing the inlet and outlet piping.

• No external loads are allowed on the inlet or outlet connection.

• Install one or more safety valves as necessary on the compressed air/nitrogen circuit to ensure that the maximum pressure of the water separator is never exceeded. The user must ensure the installation of safety valves complies with all applicable government and industry standards.

• If the circuit is subject to vibrations or pulsations, use appropriate dampers to connect the water separator.

• Ensure the compressed air/nitrogen does not contain corrosive gases. Take particular care in environments with high levels of Sulphur, Ammonia, Chlorine, and in marine applications. Stainless steel models are available for corrosive environments.

• Take care to prevent accidental contact and burns when subject to temperatures exceeding 40°C.

• Install the water separator so that the compressed air/nitrogen flows in the direction indicated by the labels.

• Use appropriate industry standard counter flanges and gaskets for piping connections.

• Install an appropriate condensate drain. Ensure the drain is capable of removing rust particles, as carbon steel materials are subject to rusting.

• Make sure that condensate drains can be visually checked for correct flow and are properly maintained.

• The water separator should not be subjected to frequent pressure cycling exceeding 500 cycles from 0 to nominal pressure over its lifetime. Consider using a compressed air/nitrogen receiver to avoid frequent pressure cycling.


How do I operate and maintain the PARKER HYPERSEP SFH019N-550N?

• Ensure the PARKER HYPERSEP SFH019N-550N is properly sized for the compressed air/nitrogen flow, pressure, and temperature.

• Verify that the condensate collected within the water separator is being completely drained.

• Verify corrosion of the water separator periodically (at least once per year) by measuring its thickness. The thickness must not be less than the minimum values specified in the technical data tables.

• **IMPORTANT:** If the water separator’s thickness falls below the specified minimum level, it must be immediately removed from service and replaced.

• **IMPORTANT:** Welding, grinding, or any other modification is strictly forbidden and will void the warranty.


How should an ultrasonic thickness measurement be performed on the PARKER HYPERSEP SFH019N-550N?

It is recommended to use qualified personnel for ultrasonic thickness measurement.

• Use an ultrasonic thickness tester suitable for painted surfaces.

• Compare all measured results to the minimum values specified in the technical data tables. Document and save the results.

• Separators with wall thicknesses less than the specified minimum values must be immediately removed from service and replaced.

• Repeat the measurements at least every 12 months at the same positions on the water separator. Increase the frequency of measurements if they are nearing the minimum values.


What are the dimensions for the PARKER HYPERSEP SFH019N-550N models?

dimensions (mm)
Model A A1 (A2) B C F
SFH019A* 370 185 627 157 168.3
SFH019N 370 185 640 170 168.3
SFH029N/A 400 200 720 200 194
SFH030N/A 400 200 720 200 194
SFH037N/A 460 230 880 230 245
SFH038N/A 460 230 880 230 245
SFH066N/A 550 275 980 260 273
SFH067N/A 550 275 980 260 273
SFH088N/A 570 285 1060 290 324
SFH089N/A 570 285 1060 290 324
SFH097N/A 660 330 1160 320 324
SFH142N/A 680 340 1255 351 406
SFH180N/A 750 375 1455 390 470
SFH209N/A 830 415 1655 430 519
SFH280N 1000 500 1745 460 630
SFH390N 1200 600 2154 550 720
SFH450N 1933 (1258) 2355 600 850
SFH550N 2088 (1338) 2835 650 1000

* A = Stainless Steel; N = Carbon Steel


What are the characteristics of the PARKER HYPERSEP SFH019N-550N models?

Model air in (D) air out (E) weight (kg) volume (dm³) pressure (bar)
SFH019N/A* PN16 – DN65 PN16 – DN65 22 11 16
SFH029N/A PN16 – DN80 PN16 – DN80 28 19
SFH030N/A PN16 – DN100 PN16 – DN80 29 19
SFH037N/A PN16 – DN100 PN16 – DN100 48 36.5
SFH038N/A PN16 – DN125 PN16 – DN100 49 36.5
SFH066N/A PN16 – DN125 PN16 – DN125 55 52
SFH067N/A PN16 – DN150 PN16 – DN125 56 52
SFH088N/A PN16 – DN150 PN16 – DN150 82 78 10
SFH089N/A PN16 – DN200 PN16 – DN150 85 78
SFH097N/A PN16 – DN200 PN16 – DN200 126 93
SFH142N/A PN10 – DN250 PN10 – DN200 148 148
SFH180N/A PN10 – DN300 PN10 – DN200 160 236 9
SFH209N/A PN10 – DN350 PN10 – DN200 205 330
SFH280N PN10 – DN350 PN10 – DN200 240 506 10
SFH390N PN10 – DN450 PN10 – DN250 420 838
SFH450N PN10 – DN500 PN10 – DN300 680 1290
SFH550N PN10 – DN600 PN10 – DN300 840 2150

* A = Stainless Steel; N = Carbon Steel


What are the minimum wall thickness values for the Carbon Steel models of the PARKER HYPERSEP SFH019N-550N?

Minimum thickness (mm)
Model Diameter Shell End Cap
Nominal thickness Minimum thickness Nominal thickness Minimum thickness
SFH019N 168.3 5 3.0 5 3.7
SFH029N 193.7 5.6 4.6 5 3.7
SFH030N 193.7 5.6 4.6 5 3.7
SFH037N 244.5 6.3 4.7 5 3.7
SFH038N 244.5 6.3 4.7 5 3.7
SFH066N 273 6.3 4.7 5 3.7
SFH067N 273 6.3 4.7 5 3.7
SFH088N 323.9 6 4.7 5 3.7
SFH089N 323.9 6 4.7 5 3.7
SFH097N 323.9 6 4.7 5 3.7
SFH142N 406 6 4.7 5 3.7
SFH180N 470 6 4.7 5 3.7
SFH209N 519 6 4.7 5 3.7
SFH280N 630 6 4.7 5 3.7
SFH390N 720 8 6.7 5 3.7
SFH450N 850 8 6.7 6 4.7
SFH550N 1000 8 6.7 6 4.7

What are the minimum wall thickness values for the Stainless Steel models of the PARKER HYPERSEP SFH019N-550N?

Minimum thickness (mm)
Model Diameter Shell End Cap
Nominal thickness Minimum thickness Nominal thickness Minimum thickness
SFH019A 168.3 3.0 2.5 5 4.0
SFH029A 193.7 5.0 4.0 5 4.0
SFH030A 193.7 5.0 4.0 5 4.0
SFH037A 244.5 5.0 4.0 5 4.0
SFH038A 244.5 5.0 4.0 5 4.0
SFH066A 273 5.0 4.0 5 4.0
SFH067A 273 5.0 4.0 5 4.0
SFH088A 323.9 5.0 4.0 5 4.0
SFH089A 323.9 5.0 4.0 5 4.0
SFH097A 323.9 5.0 4.0 5 4.0
SFH142A 406 5.0 4.0 5 4.0
SFH180A 470 5.0 4.0 5 4.0
SFH209A 519 6.0 5.0 5 4.0

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD PARKER HYPERSEP SFH019N-550N (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.