Free English OMRON FZ-SFC (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD OMRON FZ-SFC (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the safety warnings for the OMRON FZ-SFC camera?
The OMRON FZ-SFC camera is not designed or rated for ensuring the safety of persons and should not be used for such purposes.
It is likely to cause unusual loss of sight. Please do not look at the sun light directly with the lens unit.
What are the safety cautions for the OMRON FZ-SFC camera?
Please do not put the OMRON FZ-SFC on a place where direct sunshine tries the lens with the lens removed from the camera. A fire might occur unusually.
What are the safe use precautions for the OMRON FZ-SFC?
Installation Site
Do not install the product in locations subjected to the following conditions:
• Ambient temperature outside the rating
• Rapid temperature fluctuations (causing condensation)
• Relative humidity outside the range of 35 to 85%
• Presence of corrosive or flammable gases
• Presence of dust, salt, or metallic particles
• Direct vibration or shock
• Reflection of intense light (such as other laser beams or electric arc-welding machines)
• Direct sunlight or near heaters
• Water, oil, or chemical fumes or spray
• Strong magnetic or electric field
• Near high-voltage equipment or power equipment
Handling the Camera
• In the installation, tighten the screw, the lens, and the photograph ring surely.
• The Camera amplifier case is connected to the 0V line in the internal circuits. Observe the following precautions to prevent noise interference:
– Do not ground the Camera.
– Please use the plinth and the mounting bracket when you set it up.
Others
• Do not use unspecified camera cable and a strobe controller other than those that specified in this manual with the FZ controller. Connection with unspecified camera cable and/or strobe controller may malfunction at the worst case.
• If you do not use the enhancing connector on the back of the camera amplifier, do not remove the cap that is attached to the connector.
• Do not attempt to dismantle, repair, or modify the main body.
• If you suspect an error or malfunction, stop using the Controller immediately, turn OFF the power supply, and consult your OMRON representative.
• Dispose of FZ-SC5M/S5M components as industrial waste.
What are the precautions for correct use of the OMRON FZ-SFC?
Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect.
Connecting Cables
• Be sure to turn off the power before connecting or disconnecting the cables. The camera might break when the power supply detaches it while turned on.
Optical axis of the Camera
• The center of the optical axis varies with the camera used. Therefore, when installing the camera, always check the center of the image displayed on the monitor.
Maintenance
• If large dust particles adhere to the CCD, use a blowerbrush (used to clean camera lenses) to blow them off. Do not blow the dust particles with your mouth.
• Do not use thinners, benzene, acetone, or kerosene to clean the Camera.
What accessories are included with the OMRON FZ-SFC?
The OMRON FZ-SFC comes with the main unit, instruction sheet (this manual), a mounting bracket (only FZ-SFC/SF), and four screws (M2x4 only FZ-SFC/SF).
What are the general specifications for the OMRON FZ-SFC small camera?
| Item | FZ-SFC/SF | FZ-SPC/SP |
| shape | Flat type | Pencil type |
| Power consumption | 3.4W max.(13V DC, 0.26A max.) | |
| Vibration resistance | 10 to 150Hz: half-amplitude: 0.35mm; (maximum acceleration: 50m/s²), 10 times each in X, Y, and Z directions for 8 min | |
| Shock resistance | Shock resistance 150m/s²; 3 times each in 6 directions (up/down, left/right, forward/backward) | |
| Ambient Temperature | Operating: 0 to 50 °C(camera head) (with no icing nor condensation)
Operating: 0 to 45 °C(camera amplifier) (with no icing nor condensation) Storage: -25 to 65 °C (with no icing nor condensation) |
|
| Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |
| Ambient environment | No corrosive gases | |
| Degree of protection | IEC60529 IP20 (in-panel) | |
| Materials/Weight (Camera amplifier) | Cover: Galvanized sheet iron
Case: Aluminum die cast alloy (ADC-12) Base: polycarbonate ABS 60g (including base) |
|
| Materials/Weight (Camera head) | Case: Aluminum alloy (A5056)
Bracket: MC nylon Cap: Silicon rubber 70g (including bracket) |
Case: Aluminum alloy (A5056)
Base: PC/Glass fiber Cap: Silicon rubber 70g (including base) |
What are the performance specifications for the OMRON FZ-SFC camera?
| Item | FZ-SFC/SPC | FZ-SF/SP |
| Picture element | 1/3-inch color CCD | 1/3-inch monochrome CCD |
| Transmission mode | Interline reading all pixels | |
| Effective pixels | 659(H)×494(V) | |
| Pixel size | 7.4(µm)×7.4(µm) (Square pixel) | |
| Scanning method | Non-interlace mode | |
| Frame rate | 80fps | |
| Number of lines to be read | 12 lines to 480 lines | |
| Synchronization | Internal Sync. | |
| Video output | Digital (10 bits) | |
| Gain | -6dB to + 24dB | |
| Shutter speed | 1/10 to 1/50000s | |
| Lens mounting | Special mount (M10.5 P0.5) | |
What are the specifications for the small lens and photograph ring for the OMRON FZ-SFC?
| Item | FZ-LES3 | FZ-LES6 | FZ-LES16 | FZ-LES30 | FZ-LESR |
| Focal length | 3mm | 6mm | 16mm | 30mm | |
| Aperture | F2.0 | F3.4 | |||
| Materials | Lens: Optical glass Outline: Aluminum alloy (CB156) |
Aluminum alloy (A5056) | |||
| Weight | Approx. 5g | Approx. 6g | Approx. 4g | ||
How do I change the base mount position of the camera amplifier for the OMRON FZ-SFC?
The camera base attached to the bottom of the camera amplifier can also be attached to the another side of the camera amplifier. Remove the four screws (M2x7) from the base and re-attach the base to the another side of the camera amplifier. The recommended screw tightening torque is 0.32N·m. When the plinth is attached in the top side and the side, mount it by three mounting screws.
How do I use the mounting bracket for the OMRON FZ-SFC camera head?
The mounting bracket of the OMRON FZ-SFC/SF attachment is fixed by the four attached screws (M2x4) to the camera head. The recommended screw tightening torque is 0.1N·m.
How should I install the OMRON FZ-SFC camera head?
Bottom installation
When mounting the camera head from the bottom, a spacer must be used. The spacer must be 11mm or longer to prevent the camera head from coming into contact with a metallic side.
Side installation
For side installation, mount the camera head as shown in the diagram in the PDF.
How do I connect the OMRON FZ-SFC camera head and camera amplifier?
Please insert the front connector of the camera amplifier with the connector of the camera head, turn the ring, and fix firmly. When connecting, confirm that the model and serial number of the camera amplifier and camera head are the same. If the camera head and camera amplifier of a different model and serial number are connected, it will not operate normally.
How do I connect the OMRON FZ-SFC camera amplifier and camera cable?
Using the Camera cable FZ-VS (sold separately), connect the connector on the back of the camera amplifier and the camera connector on the Controller FZ series. The camera cable is polarized, so make sure that the end bearing a name plate is connected to the Controller.
How do I use the lens and photograph ring with the OMRON FZ-SFC?
1. Mount the lens and screw it in to the inner of the camera mount. To use it in a narrow view and at a short distance, put the photograph ring between the camera head and the lens after referring to an optical diagram.
2. Loosen the lens and the photographing ring to the position in which the focus of the image is suitable, and fix firmly with the lens fixation ring.
3. Rotate a knob after adjusting the brightness of the image by the diaphragm adjustment knob, detain temporarily, and fix firmly with the fixed screw on the other side.
Please use the draw out dimension of the lens within the mentioned range. The lens and the photographing ring might come off according to the environment of use when used by a dimension outside the range.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD OMRON FZ-SFC (01) PDF DOCUMENT