OMRON ZX-SF11 (01) Image

FREE ENGLISH OMRON ZX-SF11 (01) PDF DOCUMENT.
FREE ENGLISH OMRON ZX-SF11 (01) PDF USER GUIDE.
FREE ENGLISH OMRON ZX-SF11 (01) PDF USER MANUAL.
FREE ENGLISH OMRON ZX-SF11 (01) PDF OWNER GUIDE.
FREE ENGLISH OMRON ZX-SF11 (01) PDF OWNER MANUAL.
FREE ENGLISH OMRON ZX-SF11 (01) PDF REFERENCE GUIDE.
FREE ENGLISH OMRON ZX-SF11 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH OMRON ZX-SF11 (01) PDF REFERENCE MANUAL.
FREE ENGLISH OMRON ZX-SF11 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH OMRON ZX-SF11 (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD OMRON ZX-SF11 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

How do I install and remove the OMRON ZX-SF11?

Mounting to DIN Track

1. Mount the front of the Unit to the DIN Track.

2. Press the rear of the Unit onto the DIN Track.

Note: Always mount the front of the Unit first. Mounting strength may decrease if mounting is performed in the reverse order.

Connecting to the Sensor Amplifier

After mounting the Unit and Amplifier to the DIN Track, press the Unit against the left side of the Amplifier.

Removing the Unit from DIN Track

1. Press the Unit toward the front.

2. Lift the front of the Unit.


What are the specifications and ratings for the OMRON ZX-SF11?

Power supply voltage 12 to 24 V DC ±10%, Ripple (p-p): 10% max. Supplied from Sensor Amplifier.
Current consumption For 12-V power supply: 60 mA max. (Not including Sensor Amplifier current consumption or output current.)
Connectable Sensor Amplifier ZX-LDA
Connectable Sensor Amplifier version V2.100 or higher (The Sensor Amplifier version is shown on the sub-display when power is turned ON to the Sensor Amplifier.)
Number of Sensor Amplifiers 2 max.
Communications Port: RS-232C (9-pin, D-Sub connector)
Protocol: CompoWay/F
Baud rate: 38,400 bps
Data configuration: Data bits: 8, Parity: None, Start bits: 1, Stop bits: 1, Flow control: None
Indications Power: Green, Sensor communications: Green, Sensor communications error: Red, Serial communications: Green, Serial communications error: Red
Protective circuits Reverse power supply connection prevention
Ambient temperature Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20MΩ min. at 500V DC
Dielectric strength 1,000 V AC, 50/60 Hz for 1 min, leakage current: 10 mA max.
Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories Instruction sheet, two clamps

What do the indicator lights on the OMRON ZX-SF11 mean?

Name Color Description
Power indicator (POWER) Green Lit when power is supplied to the Unit.
Sensor communications indicator (SENSOR COMM BUSY) Green Lit when the Sensors are communicating with each other normally.
Sensor communications error indicator (SENSOR COMM ERR) Red Lit when there is an error in communications between the Sensors.
Serial communications indicator (SERIAL COMM BUSY) Green Lit when the Unit is communicating normally with the external device (e.g., personal computer).
Serial communications error indicator (SERIAL COMM ERR) Red Lit when there is an error in communications with the external device (e.g., personal computer).

Note: The sensor communications error indicator will light for 1 second after the power supply is turned ON, but this does not indicate an error.


What are the precautions for correct use of the OMRON ZX-SF11?

1. Conform to the specified ratings and performance.

2. Do not disconnect the connector connecting the Sensor Head and the Controller while power is being supplied, otherwise the Sensor may be damaged.

Power Supply and Wiring

1. Always connect to a ZX-LDA Smart Sensor Amplifier.

2. The total length of the serial communications cable must be 10 m or less.

Environment

Do not operate the Sensor in the following locations:

• Locations subject to strong vibration.

• Locations subject to direct sunlight or near heating equipment.

• Locations subject to high humidity.

• Locations where the Sensor would accumulate dust, dirt, metallic powder, etc.

• Locations subject to corrosive or flammable gases.

• Locations subject to exposure to organic solvents, water, oil, etc.

• Locations subject to strong electromagnetic or electrical fields.

• Locations subject to rapid changes in temperature.

• Locations subject to freezing.

Cleaning

Do not use thinners, benzine, acetone, kerosene, or other organic solvents for cleaning.


What is the function of the switch on the back of the OMRON ZX-SF11?

There is a switch on the back of the Unit. This switch must be left in the factory-set position. If the switch is changed, the communications function will be altered and communications will not operate correctly.


What should I know about the ZX Function Setting Software (ZX-SW) for the OMRON ZX-SF11?

The ZX-SW Function Setting Software enables easy wave-form displays and settings for the ZX-SF11 from a personal computer. Using this software enables even more effective application of your Smart Sensor.

Important: If a ZX-LDA Smart Sensor Amplifier that does not have the most recent software is connected, the firmware in the Smart Sensor Amplifier will be automatically updated to V2.100 or higher the first time the applications software is started. Wait for the update to finish as instructed on the display.

Note 1. The firmware cannot be updated simultaneously to two Sensor Amplifiers connected to a Calculating Unit. Connect to each Sensor Amplifier separately, update the firmware for each, and then reconnect them.

Note 2. Do not turn OFF the power supply while the firmware is being updated.

Note 3. Communications are possible only when the Sensor Amplifier is in RUN mode.

Software License

The software may be used only when the user agrees with the terms specified in the License.txt file in the setup disk.


What is the RS-232C Pin Arrangement for the OMRON ZX-SF11?

Pin No. Name
1 N.C.
2 RD
3 SD
4 N.C.
5 SG
6 N.C.
7 N.C.
8 N.C.
9 N.C.

How are the accessory clamps used with the OMRON ZX-SF11?

The clamps provided with the Unit can be used to secure the serial communications cable.