Free English OMEGA OM-21 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD OMEGA OM-21 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

How do I configure the OMEGA OM-21 data logger?

To configure the OMEGA OM-21, follow these steps:

1. Connect the data logger to a PC via the USB port. The logger status LEDs will blink for two runs.

2. When the Window Automatic playback is displayed, click on “Open folder to view files.”

3. Open the file named “PDF Logger Configuration Tool. exe”.

4. The default language is English, but you may change it to German, French, Italian, or Spanish. The generated PDF report will use the chosen language.

5. Configure your desired parameters (Temp. Unit, Password, Company Name, Alarm types, etc.).

6. Press “Save” to confirm the setting. The logger will auto-synchronize to your PC time.

7. Close the setup window and remove the logger from the PC USB port.

Note: Anytime before the logging is started, the logger can be programmed several times. If the logger is locked by password after the first configuration, the password will be required to program the logger again.


How do I start the logging function on the OMEGA OM-21?

After the OMEGA OM-21 is programmed, seal the zipped bag well. Press the “START” key for 2 seconds to start the logging. The Red LEDs will flash three runs to indicate the logging is activated.

Once started, the green LED will blink every two seconds. Note that to activate the logging function, there is a delay of 5 minutes after pressing the START key, meaning the first data is logged 10 minutes after pressing the key.


How do I stop the logging and generate a PDF report with the OMEGA OM-21?

To stop the logging, press the “STOP” key for 2 seconds. Alternatively, you may directly plug the logger into a PC USB port to stop the logging and generate the PDF file.

It takes a few seconds to generate the PDF report, during which the status LEDs will blink. Adobe Reader software is required to view the report.

Note: If the logger is taken out from a -30°C freezer, please leave it in air for a few minutes before plugging it into a PC to generate the PDF report.


What do the LED indicators signify on the OMEGA OM-21?

The LED indicators on the OMEGA OM-21 function as follows:

Low/High: The Red LED blinks when the measuring set limit value is exceeded.

OK (Standby): The Green LED blinks triple every 5 seconds when the logger is in standby mode but has not yet started to log readings.

OK (Logging): When the logging function is started, the Green LED blinks every 2 seconds.

Low bat. symbol: The Red LED blinks every 2 seconds when battery power is too low to maintain accurate logging.


What are the different alarm types available on the OMEGA OM-21?

The OMEGA OM-21 offers the following alarm types:

Single: A LED alarm is triggered immediately when the measured value exceeds the alarm threshold.

Cumulative: A LED alarm is not triggered when the measured value exceeds the alarm threshold, but only once the overall average value during the alarm delay duration exceeds the alarm threshold.

Disable: No LED alarm function during the logging process.

Note: No matter what alarm type is picked up, the LED will not stop flashing once it is triggered as ON even if the measured value later returns to the normal range.


How does the alarm delay work on the OMEGA OM-21?

For the “Single” alarm type, the preset alarm delay time is always zero.

For the “Cumulative” alarm type, the alarm delay time is adjustable from 5 minutes to 2 hours.

For example, to activate a LED flashing when the 30-minute average value of a hazardous alarm delay period is higher than 8°C, you should program the alarm delay as 30 minutes, the alarm type as cumulative, and the range as 2~8°C.


How do I use the bookmark function on the OMEGA OM-21?

To place a bookmark manually during the delivery transition, press the MARK key. You will see time stamps on the generated PDF report.


What are the default parameter settings for the OMEGA OM-21?

The default values for the OMEGA OM-21 are:

Sampling rate: 5 min

Start delay: 0 min

Temp. Unit: °C

Alarm Type: Single

Alarm delay: 0 min

Alarm Limits: 15 – 25°C

Password: disable

Company Name: blank

Language: English


What are the technical specifications of the OMEGA OM-21?

Model PDF data logger, single use
Temp. measurement By NTC thermistor, -30~70°C (-22~158°F)
Temp. resolution 0.1°C (0.1°F)
Temp. accuracy +/-0.5°C
Logging Type Single Use
Sampling points 8192 readings
Shelf Life 12 months shelf time
Operating temp. -30~70°C (Logging status); room temp.(PC status)
Operating RH% Humidity < 80%
Storage temp. -40~85°C
Storage RH% Humidity <90%
Weight ~10g
Battery 1PC 3.0V CR2032 (installed before shipment)
Sampling interval 30 seconds, 5, 10, 30, 60, 90, 120 minutes
Start delay 0, 5, 30, 45, 60, 90, 120 minutes
Alarm range -20~ -10°C, -10~0°C, 2~8°C, 0~15°C, 0~25°C, 15~25°C or other values
Alarm delay 0, 5, 30, 45, 60, 90, 120 minutes
Alarm type Single, Cumulative, Disable
Operation keys 2 Keys, Start/Stop & Mark
LED indicator REC, Low Bat., High/Low alarm
Protection class IP65
Directives EN12830, FDA21 CFR Part 11
Operating System Windows only
NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD OMEGA OM-21 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.