What is the purpose of the NATIONAL INSTRUMENTS 9694?

The NATIONAL INSTRUMENTS 9694 is a Digital I/O Breakout RMC. It is used to connect and use digital I/O with NI sbRIO devices through the RIO Mezzanine Card (RMC) connector.


What safety precautions should be followed when using the NATIONAL INSTRUMENTS 9694?

Do not operate the NATIONAL INSTRUMENTS 9694 in a manner not specified in the operating instructions. Product misuse can result in a hazard and may compromise the safety protection built into the product.

If the product is damaged in any way, do not use it and return it to National Instruments for repair.

Additionally, note that National Instruments makes no product safety, electromagnetic compatibility (EMC), or CE marking compliance claims for NI sbRIO devices. The end-product supplier is responsible for conformity to all compliance requirements.


How do I mate and mount the NATIONAL INSTRUMENTS 9694 to an NI sbRIO device?

The device mates via the RMC connector. For mounting, the mounting holes on the NI sbRIO device are designed to accommodate specific fasteners.

Compatible fasteners: M3 or 4-40 fasteners.

Standoffs or bosses: Up to 4.5 mm or 3/16 in. in diameter.


What are the Digital I/O channel specifications for the NATIONAL INSTRUMENTS 9694?

The NATIONAL INSTRUMENTS 9694 features the following channel configurations:

On screw terminals: 64 channels

On 100-mil spacing holes: 32 channels


What are the current limits for the NATIONAL INSTRUMENTS 9694 Digital I/O?

Max tested current per channel: +/- 3 mA

Max tested current, all lines: 288 mA


What are the input and output logic levels for the NATIONAL INSTRUMENTS 9694?

The logic levels for the 3.3 V Digital I/O are as follows:

Parameter Specification
Input low voltage (VIL) 0 V min; 0.8 V max
Input high voltage (VIH) 2.0 V min; 3.465 V max
Output high voltage (VOH), sourcing 3 mA 2.4 V min; 3.465 V max
Output low voltage (VOL), sinking 3 mA 0.0 V min; 0.4 V max

What are the power output specifications for the NATIONAL INSTRUMENTS 9694?

5 V: 1.5 A, +/- 5% voltage tolerance

FPGA VIO (3.3 V): 0.33 A, +/- 5% voltage tolerance


What fuses are used in the NATIONAL INSTRUMENTS 9694?

The device uses the following fuses:

Fuse Type Manufacturer Part Number Rating Voltage Speed
5 V fuse (F2) Littelfuse 0454002 (or equivalent) 2 A 125 V Time delay
FPGA VIO fuse (F1) Littelfuse 0454.750 (or equivalent) 750 mA 125 V Time delay

What are the environmental specifications for operating the NATIONAL INSTRUMENTS 9694?

The NATIONAL INSTRUMENTS 9694 is for indoor use only.

Local ambient temperature near device (IEC 60068-2-1, IEC 60068-2-2): -40 to 85 Degrees C

Operating humidity (IEC 60068-2-56): 10 to 90%, noncondensing

Storage humidity (IEC 60068-2-56): 5 to 90%, noncondensing

Maximum altitude: 5,000 m

Pollution Degree: 2


What is the storage temperature range for the NATIONAL INSTRUMENTS 9694?

The storage temperature range (IEC 60068-2-1, IEC 60068-2-2) is -40 to 85 Degrees C.


What is the weight of the NATIONAL INSTRUMENTS 9694?

The device weighs 82 g (2.89 oz).