What is the function of the AIPHONE MYW-P10L adaptor?

The AIPHONE MYW-P10L adaptor allows up to 10 2-wire video door stations to be used with the LEF series Master Sentry System. MY or MK PanTilt series video door stations may be used with the AIPHONE MYW-P10L. Additionally, CCTV cameras may be connected through the unit using the MYW-MD/B adaptor.


What do the terminal definitions on the AIPHONE MYW-P10L indicate?

The terminal definitions found inside the AIPHONE MYW-P10L and in the external terminal box are as follows:

Terminal Description
nA1 Input from MY/MK Series video door station
nA2 Input from MY/MK Series video door station
B1 Video signal output to monitors
B2 Video signal output to monitors
U1 Video activation to monitors
U2 Video activation to monitors
18V+ Positive 18V DC
18V- Negative
N1, N2 Unused
1 ~ 10 Audio communication
E Common communication
12V+ Positive 12V DC
12V- Negative
K1 ~ K10 Video control terminals

Do the switches on the front of the AIPHONE MYW-P10L control the monitor functions?

No. The MONITOR button, Auto-Scan Duration, and Monitor Receive Volume switches on the front of the unit are non-functional.


What are the operational steps when a video door station calls in on the AIPHONE MYW-P10L system?

1. When a video door station calls in, all monitors in the system will activate, and the appropriate LED will illuminate on the LEF master. The call tone will be heard until the call is answered or for 5 seconds, whichever comes first. The monitor will turn off in 45 seconds if the call is not answered. The LED will remain lit for approximately 20 seconds after the tone is no longer heard.

2. While the monitor is active, the PanTilt button may be used to control the camera position (PanTilt cameras only).

3. If the door is not selected within 45 seconds, the monitor will turn off. Communication and video can be established by pressing the appropriate selector button on the LEF master.

4. When called by a door station while communicating, only the LED will activate. Press the OFF button to end the existing conversation, then select the door button to establish communication and video.


How do I monitor a door station using the AIPHONE MYW-P10L?

1. On the LEF master, press the selector button of the door that you wish to monitor.

2. The video monitor will turn on showing the selected door, remaining active for approximately 2-1/2 minutes.

3. Communicate with the door using the LEF master station.

4. Press the OFF button on the LEF master to end the conversation.


How do I initialize the AIPHONE MYW-P10L when used with CCTV cameras?

If the AIPHONE MYW-P10L is used with CCTV cameras and MYW-MD/B’s, the unit must be initialized before operation. Follow these steps:

Note: To avoid a constant call tone on the LEF during this process, unplug the PS-1225UL power supply.

1. Turn the power switch on the AIPHONE MYW-P10L OFF.

2. Turn switches associated with CCTV camera locations to the ON position. These switches are located inside the bottom of the unit. (For example, if stations 4, 5, 6 are CCTV cameras, set switches 4, 5, and 6 to ON).

3. Turn the AIPHONE MYW-P10L power switch ON.

4. Wait for the red STANDBY light to go out. (The STANDBY light is located on the face of the unit).

5. Turn switches associated with the camera locations back to the OFF position.

6. The system is now operational.


How can I turn off the pre-tone on the AIPHONE MYW-P10L?

When a door station is selected, a short pre-tone is heard. To turn this off:

1. Remove the top left cover of the AIPHONE MYW-P10L.

2. Move the second switch from the left to the OFF position.


What should I do if the AIPHONE MYW-P10L malfunctions?

If the AIPHONE MYW-P10L malfunctions, press the reset switch located under the top left coverplate of the unit.


What requirements are there for using door release relays with the AIPHONE MYW-P10L?

Diodes shown in the wiring diagram must be used when using RY-PA door release relays. They are 1N4007 and are included in the box with the unit. When using door release relays, install the cathode side of the supplied 1N4007 diodes directly to the K terminals of the AIPHONE MYW-P10L, and connect the black wire of RY-PA to the anode side of the diode. Do not install diodes on K terminals at the LEF master station.


What are the power and wiring specifications for the AIPHONE MYW-P10L?

Power Source: 18V DC. Use PS-1820UL for every 3 video components.

Wiring Distance:

AIPHONE MYW-P10L to MK series Video door station: 330′ using 18 AWG.

AIPHONE MYW-P10L to farthest MY series monitor: 245′ using 18 AWG.

AIPHONE MYW-P10L to farthest LEF-10: 650′ using 22AWG; 1600′ using 18AWG.

Dimensions (HxWxD): 4-1/2″ X 7-11/16″ X 9″

Weight: 3.31 lbs. (Approx.)


How does the calling function work on the AIPHONE MYW-P10L?

The system uses an electronic call tone and LED on the LEF master. The call tone remains active for 5 seconds. The LED remains activated for 25 seconds, or until the call is answered, whichever comes first. Monitors stay activated for 45 seconds.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD AIPHONE MYW-P10L (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.