Free English MIDEA MAP14S1TBL (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD MIDEA MAP14S1TBL (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the key safety warnings I should be aware of when using my MIDEA MAP14S1TBL air conditioner?
To prevent injury and property damage, please follow these safety warnings for your MIDEA MAP14S1TBL:
• Be sure the air conditioner has been securely and correctly installed according to the installation instructions.
• Plug the power cord plug in properly. An improper connection may cause electric shock or fire due to excess heat generation.
• Do not modify the power cord length or share the outlet with other appliances, as this may cause electric shock or fire due to overheating.
• Always ensure effective grounding. Incorrect grounding may cause electric shock.
• Unplug the unit if you notice unusual sounds, smells, or smoke coming from it. A damaged product may cause fire and electric shock.
• Ventilate the room before operating the air conditioner if there is a gas leakage from another appliance.
• Do not operate or stop the unit by inserting or pulling out the power cord plug.
• Do not operate with wet hands or in very humid environments, as it may cause electric shock.
• Do not allow water to come into contact with any electric parts, which could cause failure or electric shock.
• Do not use a socket if it is loose or damaged, as it may cause fire and electric shock.
• Do not use or keep the power cord close to heating appliances, which may cause fire and electric shock.
• Do not use any devices or materials for installation that are not recommended in the manual.
• Do not disassemble or modify the unit, as it may cause failure and electric shock.
• Do not damage or use an alternate power cord. If the power cord is damaged, it must be replaced by the manufacturer to avoid a hazard.
• Do not direct airflow straight at persons to avoid possible health hazards.
• Do not open the unit during operation, as it may cause electric shock.
• Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc., as it may cause an explosion or fire.
• Do not let children on the air conditioner, as a serious injury may occur.
• Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prongs from the power cord.
• Be sure the air conditioner is properly grounded. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
• Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
What are the important safety cautions for my MIDEA MAP14S1TBL air conditioner?
Please observe the following cautions when handling your MIDEA MAP14S1TBL:
• When the air filter is removed, do not touch the metal parts of the unit to avoid injury.
• Always unplug the unit before cleaning to prevent fire, electric shock, or injury.
• Do not place obstacles around air inlets or inside of the air outlet, as this may cause failure or an accident.
• Clean with a soft cloth only. Do not use strong detergents containing wax or thinners, as they may damage the product.
• Use caution when unpacking and installing. Sharp edges could cause injury.
• Do not clean the air conditioner with water, as it may enter the unit and degrade the insulation, leading to electric shock.
• Hold the plug by the head of the power plug when taking it out to prevent electric shock and damage.
• Ensure the installation is properly secured to prevent the product from falling.
• Do not place heavy objects on the power cord and ensure the cord is not compressed to avoid fire or electric shock.
• If water is spilled on the unit, turn off the unit and the circuit breaker, then unplug it and contact a qualified service technician.
• Do not use near a gas stove or other gas burning appliances, as airflow may affect gas combustion.
• Do not use this air conditioner for purposes other than room comfort, such as preserving precision devices, food, pets, plants, and art objects.
• Turn off the main power switch if the unit is not to be used for an extended time.
• Always insert the filters securely. Clean the filter once every two weeks. Operation without filters may cause failure.
• Do not drink water drained from the air conditioner.
What do the symbols displayed on my MIDEA MAP14S1TBL unit mean?
| Symbol | Meaning |
|---|---|
| WARNING | This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. |
| CAUTION | This symbol shows that the operation manual should be read carefully. |
| CAUTION | This symbol shows that a service personnel should be handling this equipment with reference to the installation manual. |
| CAUTION | This symbol shows that information is available such as the operating manual or installation manual. |
What are the specific warnings for using R32 refrigerant with my MIDEA MAP14S1TBL?
If your MIDEA MAP14S1TBL uses R32 refrigerant, please follow these warnings carefully:
• Do not try to accelerate the defrosting process or use methods of cleaning that are not recommended by the manufacturer.
• The appliance shall be stored in a room without a continuously operating ignition source (e.g., open flames, an operating gas appliance, or an operating electric heater).
• Do not pierce or burn the appliance.
• Be aware that the refrigerants may not contain an odor.
• Keep ventilation openings clear of obstruction.
• Flammable refrigerant R32 is used within the air conditioner. Follow instructions carefully to handle, install, clean, and service the air conditioner to avoid damage or hazard. Do not dispose of the air conditioner in regular trash; contact a qualified agency for proper disposal.
• No open fire or devices that generate spark/arcing shall be around the air conditioner to avoid causing ignition of the flammable refrigerant used. Follow instructions carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
How do I test the power supply cord on my MIDEA MAP14S1TBL?
The power supply cord contains a current measuring device that detects damage. To test your power supply cord, follow these steps:
1. Plug in the air conditioner.
2. The power supply cord will have two buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
3. Press the RESET Button. You will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. On some products, this is also indicated by a light on the plug head.
NOTE: Always make sure the RESET button is pushed in for correct operation. The power supply cord must be replaced if it fails to reset when the TEST button is pushed, or if it cannot be reset. If the power supply cord is damaged, it cannot be repaired and must be replaced.
What are the operating temperature ranges for the different modes of the MIDEA MAP14S1TBL?
| Mode | Temperature Range |
|---|---|
| Cool | 60°F ~ 95°F (16°C ~ 35°C) |
| Dry | 55°F ~ 95°F (13°C ~ 35°C) |
| Heat Pump | 41°F ~ 86°F (5°C ~ 30°C) |
How do I use the control panel buttons on my MIDEA MAP14S1TBL?
Here is a guide to the control panel features of your MIDEA MAP14S1TBL:
• Swing Button: Used to initiate the Auto Swing feature. When the operation is ON, pressing the SWING button can stop the louver at the desired angle.
• Connect Button (also Swing button): Press and hold the SWING button for 3 seconds to initiate the wireless connection mode. The LED Display will show ‘AP’.
• Timer button: Used to initiate the AUTO ON start time and AUTO OFF stop time program.
• Fan button: Controls the fan speed in four steps – LOW, MID, HIGH and AUTO. In COOL or DRY mode, press the Fan button for 3 seconds to turn the constant fan function on or off.
• Mode button: Selects the desired operating mode. Each press cycles through AUTO, COOL, DRY, FAN and HEAT (for heat pump models).
• Up (▲) and Down (▼) buttons: Used to increase/decrease temperature settings in 1° increments (60°F/16°C to 86°F/30°C) or the TIMER setting in a range of 0 ~ 24hrs. To change between °F and °C, press and hold both buttons simultaneously for 3 seconds.
• Power button: Turns the unit on and off.
• Sleep button: Press to initiate the SLEEP operation. Press again to stop. Press and hold for 3 seconds to initiate the filter clean reminder feature. The LED will illuminate after 250 hours of operation as a reminder to clean the filter.
• LED display: Shows the set temperature in °F or °C and the Auto-timer settings. In FAN mode, it shows the room temperature.
How do I set the COOL operation on my MIDEA MAP14S1TBL?
1. Press the “MODE” button until the “COOL” indicator light comes on.
2. Press the ADJUST buttons Up (▲) or Down (▼) to select your desired room temperature. The temperature can be set within a range of 60°F~86°F / 16°C~30°C.
3. Press the “FAN SPEED” button to choose the fan speed.
How do I set the HEAT operation on my MIDEA MAP14S1TBL?
1. Press the “MODE” button until the “HEAT” indicator light comes on.
2. Press the ADJUST buttons Up (▲) or Down (▼) to select your desired room temperature. The temperature can be set within a range of 60°F~86°F / 16°C~30°C.
3. Press the “FAN SPEED” button to choose the fan speed. For some models, the fan speed cannot be adjusted while in HEAT mode.
How do I set the DRY operation on my MIDEA MAP14S1TBL?
1. Press the “MODE” button until the “DRY” indicator light comes on.
2. In this mode, you cannot select a fan speed. The fan motor operates at AUTO speed.
3. Keep windows and doors closed for the best dehumidifying effect.
4. Do not put the duct to the window.
How does the AUTO operation work on the MIDEA MAP14S1TBL?
When you set the air conditioner to AUTO mode, it will automatically select cooling, heating (cooling only models excluded), or fan only operation depending on the temperature you have selected and the current room temperature. The air conditioner will control the room temperature automatically according to the temperature point you set. Under AUTO mode, you cannot select the fan speed.
How do I use the FAN only operation on my MIDEA MAP14S1TBL?
1. Press the “MODE” button until the “FAN” indicator light comes on.
2. Press the “FAN SPEED” button to choose the fan speed.
3. The temperature cannot be adjusted in FAN mode.
4. Do not connect the duct to a window.
How do I set the TIMER for Auto Start/Stop on my MIDEA MAP14S1TBL?
• To set Auto Stop: When the unit is on, press the Timer button to initiate the Auto stop program. The TIMER OFF indicator will light up. Press the Up (▲) or Down (▼) button to select the desired time. Press the TIMER button again within 5 seconds.
• To set Auto Start: When the unit is off, press the Timer button to initiate the Auto start program. Press it again within five seconds to initiate the Auto stop program as well if desired. Press the Up (▲) or Down (▼) button to select the desired start time.
• Adjusting Time: Press or hold the Up (▲) or Down (▼) button to change the Auto time by 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
• Cancelling Timer: Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program.
What does the P1 error code mean on my MIDEA MAP14S1TBL and how do I fix it?
The “P1” error code means the bottom collection tray is full of water. The unit will beep 8 times, and the air conditioning/dehumidification process will stop, though the fan motor will continue to operate.
To fix this, carefully move the unit to a drain location, remove the bottom drain plug, and let the water drain away. Reinstall the bottom drain plug firmly and restart the machine. The “P1” symbol should disappear. If the error repeats, call for service.
How does the SLEEP operation work on the MIDEA MAP14S1TBL?
Pressing the SLEEP button will cause the unit to adjust the temperature for energy savings during sleep. The temperature will increase (during cooling) or decrease (during heating) by 2°F/1°C after 30 minutes. It will adjust by another 2°F/1°C after an additional 30 minutes. This new temperature will be maintained for 7 hours before the unit returns to the originally selected temperature. This ends the Sleep mode. The SLEEP operation feature is unavailable in FAN or DRY mode.
What is the COMFORT SENSE feature on my MIDEA MAP14S1TBL?
The COMFORT SENSE feature can ONLY be activated from the remote control. It allows the remote to act as a remote thermostat for precise temperature control at its location (must be within 26 feet of the unit). To activate, point the remote control towards the unit and press the set button to select. The remote will display the temperature at its location and send this signal to the air conditioner every 3 minutes. If the unit does not receive the signal for any 7-minute interval, it will exit Comfort Sense mode. This feature is unavailable in FAN or DRY mode.
What is the AUTO-RESTART feature on my MIDEA MAP14S1TBL?
If your MIDEA MAP14S1TBL shuts off unexpectedly due to a power outage, the AUTO-RESTART feature will automatically restart the unit with the previously set function once power is restored.
How do I adjust the airflow direction on my MIDEA MAP14S1TBL?
The louver can be adjusted automatically using the SWING button on the control panel or remote controller.
• When the power is ON, the louver opens fully.
• Press the SWING button to initiate the Auto Swing feature. The louver will swing up and down automatically.
Please do not adjust the louver manually.
How do I set up water drainage for DRY mode on my MIDEA MAP14S1TBL?
During Dry modes, you can set up continuous drainage. Remove the upper drain plug from the back of the unit and install the drain connector (5/8″ universal female adapter) with a 3/4″ hose (not included). For models without a drain connector, just attach the drain hose to the hole. Place the end of the hose directly in the drain area you’re using.
How do I set up water drainage for HEAT mode on my MIDEA MAP14S1TBL?
For continuous drainage in heat mode, remove the middle drain plug from the back of the unit and install the drain connector (5/8″ universal female adapter) with a 3/4″ hose (not included). For models without a drain connector, attach the drain hose to the connector. Place the end of the hose in your drain area.
The drain hose can be elevated up to 6ft (1.8m). Direct the hose toward the drain, making sure there are no kinks that will restrict water flow. Place the end of the hose into the drain and make sure the end of the hose is directed downward. When the continuous drain hose is not used, ensure that the corresponding drain plug and knob are installed firmly to prevent leaks.
What are the requirements for choosing an installation location for my MIDEA MAP14S1TBL?
Your installation location for the MIDEA MAP14S1TBL should meet the following requirements:
• Install your unit on an even surface to minimize noise and vibration.
• The unit must be installed near a grounded plug, and the Collection Tray Drain (on the back of the unit) must be accessible.
• The unit should be located at least 9.8″ (25cm) from the nearest wall to ensure proper air conditioning.
• The horizontal louver blade should be at least 19.7″ (50cm) away from obstacles.
• DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage.
What accessories are included with the MIDEA MAP14S1TBL window installation kit?
| Part Description | Quantity |
|---|---|
| Air exhaust adapter | 1 pc |
| Bolt | 8 pc |
| Window Sliders | 5 pc |
| Window Kit Brace | 1 pc |
| Sliding Window Adapter – Front | 1 pc |
| Sliding Window Adapter – Rear | 1 pc |
| Sliding Window Adapter – Air Divider | 1 pc |
| Power Cord Buckle (only for cooling model) | 1 pc(*) |
| Foam seal A (adhesive) | 4 pc |
| Foam seal B (adhesive) | 2 pc |
| Foam seal C (Non-adhesive) | 2 pc |
| Security bracket and 2 screws | 1 set |
| Drain hose | 1 pc |
| Drain hose adaptor (For heat pump mode only) | 1 pc |
| Remote controller and battery | 1 set |
| Insulator | 2 pc |
| Air Hose Insulator (only for heat pump mode) | 1 pc |
| Ribbon (only for heat pump mode) | 2 pc |
| 1 Screw (on Exhaust adaptor) | 1 pc |
How do I prepare the adjustable window slider for my MIDEA MAP14S1TBL?
1. Depending on the size of your window, adjust the size of the window slider.
2. If the length of the window requires two or more window sliders, use the bolt to fasten the window sliders once they are adjusted to the proper length.
3. Paste the insulator on the inside of the Window sliders.
How do I install the window kit for a hung window with my MIDEA MAP14S1TBL?
1. Cut the adhesive foam seal A and B strips to the proper lengths and attach them to the window sash and frame.
2. Insert the window slider assembly into the window opening. If the hose opening is covered by the window frame, rotate the panel so the thicker side faces the window frame. Attach the Window Kit Brace to the back of the hose panel, trimming the brace if necessary.
3. Cut the non-adhesive foam seal C strip to match the width of the window. Insert the seal between the glass and the window frame to prevent air and insects from getting into the room.
4. If desired, install the security bracket with 2 screws as shown.
5. Attach the Hung Window Adapter to the hose by lining up the circles on the adapter and the hose. Insert the window slider adapter into the hole of the window slider.
How do I install the window kit for a sliding window with my MIDEA MAP14S1TBL?
1. Assemble the Sliding Window Adapter by aligning both halves and connecting them. Then, attach the air divider to the outdoor side of the newly formed adapter.
2. Cut the adhesive foam seal A and B strips to the proper lengths and attach them to the window sash and frame.
3. Insert the window slider assembly into the window opening. If the hose opening is covered by the window frame, rotate the panel so the thicker side faces the window frame. Attach the Window Kit Brace to the back of the hose panel, trimming the brace if necessary.
4. Cut the non-adhesive foam seal C strip to match the height of the window. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.
5. If desired, install the security bracket with 2 screws as shown.
6. Attach the Sliding Window Adapter to the hose by lining up the circles on the adapter and the hose. Insert the window slider adapter into the hole of the window slider.
How do I install the air hose insulator for heat pump mode on my MIDEA MAP14S1TBL?
When the unit is in heat mode, the Air Hose insulator must be fixed to the hose.
1. Cover the Air Hose with the Air Hose insulator.
2. Pull out the Air Hose and cut the useless part of the Air Hose insulator.
3. Tighten the air hose with the Ribbons and cut the useless part.
What are the safety precautions for cleaning my MIDEA MAP14S1TBL?
• Always unplug the unit before cleaning or servicing.
• DO NOT use flammable liquids or chemicals to clean the unit.
• DO NOT wash the unit under running water. Doing so causes electrical danger.
• DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
How do I clean the air filter on my MIDEA MAP14S1TBL?
To clean the air filter, take out the upper filter. It is important to operate the unit with the filter in place, as dirt and lint can clog it and reduce performance. Be sure to clean the air filter every 2 weeks for optimal performance.
How do I properly store my MIDEA MAP14S1TBL when it’s not in use?
1. Drain the unit’s water collection tray completely.
2. Run the unit on FAN mode for 12 hours in a warm room to dry it and prevent mold.
3. Turn off the unit and unplug it.
4. Clean the air filter according to the instructions. Reinstall the clean, dry filter before storing.
5. Remove the batteries from the remote control.
Be sure to store the unit in a cool, dark place. Exposure to direct sunlight or extreme heat can shorten its lifespan.
What should I do if my MIDEA MAP14S1TBL does not turn on when I press the ON/OFF button?
This could be due to the P1 Error Code, which means the water collection tray is full. Turn off the unit, drain the water from the water collection tray, and restart the unit.
Why is my MIDEA MAP14S1TBL not cooling well and what should I do?
There are several potential reasons why your air conditioner may not be cooling well. Check the following:
• Room vs. Set Temperature: If the room temperature is lower than the set temperature in COOL mode, reset the temperature.
• Blocked Air Filter: The air filter may be blocked with dust or animal hair. Turn off the unit and clean the filter according to the instructions.
• Exhaust Hose: The exhaust hose may not be connected or could be blocked. Turn off the unit, disconnect the hose, check for blockage, and reconnect the hose.
• Temperature Setting: The temperature setting might be too high; decrease the set temperature.
• Open Windows/Doors: Make sure all windows and doors are closed.
• Room Size: The room area could be too large for the unit’s capacity.
• Heat Sources: Check the room for possible heat sources and remove them if possible.
What should I do if my MIDEA MAP14S1TBL is noisy or vibrates too much?
If your unit is noisy or vibrating excessively, check the following:
• Level Surface: The floor may not be level. Place the unit on a flat, level surface.
• Blocked Air Filter: The air filter may be blocked with dust or animal hair. Turn off the unit and clean the filter according to the instructions.
Why does my MIDEA MAP14S1TBL make a gurgling sound?
This sound is caused by the refrigerant flow inside the unit and is normal.
What should I do if the top of the window kit for my MIDEA MAP14S1TBL leans forward out of the window track?
Ensure the Window Kit brace is installed properly to support the window kit and prevent it from leaning.
How do I insert or replace the batteries in the remote control for my MIDEA MAP14S1TBL?
Your MIDEA MAP14S1TBL may come with two AAA batteries. To install them:
1. Slide the back cover from the remote control downward, exposing the battery compartment.
2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
3. Slide the battery cover back into place.
For optimum performance, do not mix old and new batteries, and do not leave batteries in the remote if you don’t plan on using it for more than 2 months.
What are the specifications for the MIDEA MAP14S1TBL remote control?
| Specification | Value |
|---|---|
| Model | RG10F2(B2)/BGEFU1 |
| Rated Voltage | 3.0V (Dry batteries R03/LR03x2) |
| Signal Receiving Range | 26 ft (8 m) |
| Environment | -5 °C ~ 60 °C (23°F ~ 140°F) |
What are the functions of the buttons on the remote control for the MIDEA MAP14S1TBL?
• ON/OFF: Turns the unit on or off.
• MODE: Switches the operating modes (Auto → Cool → Dry → Heat → Fan).
• TEMP ▲: Increases temperature in 1°F (1°C) increments. Max temperature is 86°F (30°C).
• TEMP ▼: Decreases temperature in 1°F (1°C) increments. Min temperature is 60°F (16°C).
• FAN SPEED: Switches the fan speed (Auto → Low → Medium → High).
• TIMER ON: Sets timer to turn the unit on.
• TIMER OFF: Sets timer to turn the unit off.
• SWING: Starts and stops the horizontal louver movement.
• SLEEP: Saves energy during sleeping hours.
• LED: Turns the unit’s LED display and control panel beeps on or off.
• °C/°F: Changes the temperature units between Celsius and Fahrenheit.
• SET: Scrolls through operation functions like Comfort Sense and AP mode.
• OK: Press to send the desired settings to the AC unit.
• SHORTCUT: Used to restore the current settings or resume previous settings.
How do I set the TIMER ON and TIMER OFF using the remote control for my MIDEA MAP14S1TBL?
TIMER ON SETTING:
1. Press the TIMER ON button to initiate the ON time sequence.
2. Press the up or down button multiple times to set the desired time to turn on the unit.
3. Point the remote to the unit and wait 1 second; the TIMER ON will be activated.
TIMER OFF SETTING:
1. Press the TIMER OFF button to initiate the OFF time sequence.
2. Press the up or down button multiple times to set the desired time to turn off the unit.
3. Point the remote to the unit and wait 1 second; the TIMER OFF will be activated.
Note: When setting the timer, the time will increase by 30-minute increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1-hour increments. The timer will revert to 0.0 after 24. You can cancel either function by setting its timer to 0.0h.
What are the specifications of the wireless module for the MIDEA MAP14S1TBL?
| Specification | Value |
|---|---|
| Model | US-OSK103 |
| Standard | IEEE 802.11 b/g/n |
| Antenna Type | External omnidirectional Antenna |
| Frequency | 2.4 GHz (wireless) |
| Maximum Transmitted Power | 19.8 dBm Max |
| Dimensions | 41 x 24 x 5 (mm) |
| Operation Temperature | 0°C ~ 45°C / 32°F ~ 113°F |
| Operation Humidity | 10% ~ 85% |
| Power Input | DC 5V/300 mA |
What are the precautions for using the smart features of the MIDEA MAP14S1TBL?
1. Supports operating systems: iOS 7+ or Android 4+.
2. In the event of an OS update, there may be a delay until a new software version is released for support.
3. This Smart AC only supports WPA-PSK/WPA2-PSK (recommended) encryption.
4. To ensure proper scanning of the QR code, your smart phone must have at least a 5-megapixel camera.
5. Due to unstable network connectivity, requests may time out. If this happens, re-run the network configuration.
6. Due to unstable network connectivity, commands may time out. If this happens, the smartphone app and the actual product may display conflicting information. The information displayed on the actual product is always the most accurate available. Refresh the app to re-sync.
What is SACC and why is the cooling capacity on my new MIDEA MAP14S1TBL lower than on older units?
SACC is the representative value of Seasonally Adjusted Cooling Capacity, in Btu/h, as determined in accordance with the DOE test procedure. Due to a new federal test procedure for Portable Air Conditioners, the cooling capacity claims on packaging for models produced after 2017 are significantly lower than those of models produced prior to 2017. This change is due to the new test procedure, not a change in the air conditioners themselves. So, while the BTUs listed may be lower, the actual cooling capacity of the air conditioners has not changed.