FREE ENGLISH MARANTZ SR225 (01) PDF USER GUIDE
FREE ENGLISH MARANTZ SR225 (01) PDF USER MANUAL
FREE ENGLISH MARANTZ SR225 (01) PDF OWNER GUIDE
FREE ENGLISH MARANTZ SR225 (01) PDF OWNER MANUAL
FREE ENGLISH MARANTZ SR225 (01) PDF REFERENCE GUIDE
FREE ENGLISH MARANTZ SR225 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH MARANTZ SR225 (01) PDF REFERENCE MANUAL
FREE ENGLISH MARANTZ SR225 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH MARANTZ SR225 (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD MARANTZ SR225 (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How can I order parts for my Marantz SR225?

Parts for your MARANTZ stereo are generally available within 72 hours throughout the nation via a toll-free line to the National Parts Depot in California. Phone orders are encouraged to eliminate mail delays. If ordering by mail, use MARANTZ parts order forms available from the National Parts Depot.

USA Contact:

SUPERSCOPE NATIONAL PARTS DEPARTMENT
20525 Nordhoff Street
Chatsworth, California 91311
Phone: 1-800-423-5108 or 1-213-998-9333

Required Information for Ordering:

1. Complete address.

2. Complete part numbers.

3. Complete description of parts.

4. Model number for which part is required (indicate MARANTZ).

5. Account number (for account customers only).

Direct consumers will be provided with the current retail price quotation on available parts to advise them of the cost of parts and shipping.


What is the Shock Fire Hazard Service Test and how is it performed?

CAUTION: After servicing this appliance and prior to returning to the customer, perform this mandatory test.

Procedure:

1. Ensure the unit is NOT connected to AC mains.

2. Turn the unit’s Power switch ON.

3. Measure the resistance between either primary AC cord connector pin and the face or front Panel of the product, controls, and chassis bottom.

Requirement: The resistance measurement must be greater than 1 Megohm.

If the resistance is less than 1 Megohm, the unit must be repaired and corrected before AC power is applied, and verified before return to the user/customer.

(Ref. UL Standard No. 1270. Para. 66. 3. D – Mandatory Test after servicing Electrical Appliances, effective 7-1-83).


What test equipment is required for servicing the SR225 Receiver?

Item Manufacturer and Model No. Use
AM Signal Generator Signal source for AM alignment
Test Loop Use with AM Signal Generator
FM Signal Generator
MPX Signal Generator
Sound Technology Model 1000A Signal source for FM alignment
Stereo separation alignment and trouble shooting
Distortion Analyzer
Audio Oscillator
AC VTVM
Sound Technology Model 1700A Distortion measurements
Sinewave and squarewave signal source
Voltage measurements (AC)
Oscilloscope Tektronix Model T932
Philips Model 3232
Waveform analysis and trouble shooting and ASO alignment
Frequency Counter Fluke Model 1900A ASO alignment
Circuit Tester Trouble shooting
DC VTVM Fluke Model 8,000 “Digital” Simpson
Model 313, Triplet Model 801
Voltage measurements (DC)
AC Wattmeter Simpson Model 1379 Monitors primary power to amplifier
AC Ammeter Commercial Grade (1-10A) Monitors amplifier output under short circuit condition
Line Voltmeter Simpson Model 1359 Monitors potential of primary power to amplifier
Variable Autotransformer Superior Electronic Co., Powerstat
Model 116B-10A
Adjusts level of primary power to amplifier
Shorting Plug Use phono plug with 600-ohm across center pin and shell Shorts amplifier input to eliminate noise pickup
Output Load (8 ohms, ± 0.5%), 100W) Commercial Grade Provides 8-ohm load for amplifier output termination
Output Load (4 ohms, ± 0.5%, 100W Commercial Grade Provides 4-ohm load for amplifier output termination.

How do I perform the FM RF Alignment?

Note: Set the Function Switch to the “FM” position. Connect a Dummy Resistor of 47K-ohms across the output terminals before alignment.

STEP SIGNAL SOURCE CONNECTION SIGNAL FREQUENCY INDICATOR CONNECTION SET DIAL POINTER TO: ADJUST
1 RF GENERATOR TO FM ANTENNA TERMINALS THROUGH MATCHING NETWORK (300 OHMS, BALANCED). (MAINTAIN RF LEVEL BELOW LIMIT.) 87.35 MHz VTVM TO L OR R CHANNEL OUTPUT TUNING CAPACITOR MINIMUM CLOSED L3 FOR MAXIMUM OUTPUT
2 108.25 MHz TUNING CAPACITOR MAXIMUM OPEN. OSC TRIMMER CAPACITOR FOR MAXIMUM OUTPUT
3 90 MHz 90 MHz L1, L2, FOR MAXIMUM OUTPUT.
4 106 MHz 106 MHz ANT. RF. TRIM. CAP. FOR MAXIMUM OUTPUT.
5 REPEAT STEPS 1 TO 4.
6 CHECK OVERALL RESPONSE CURVE STEPS AS NECESSARY TO OBTAIN MAXIMUM SENSITIVITY.
7 RF GENERATOR 1 MV (OR 300 UV, ONLY STEP 10) OUTPUT TO FM ANTENNA TERMINALS THROUGH MATCHING NETWORK. (300 OHMS, BALANCED) 98 MHz CENTER METER CONNECT TO ANY WAY OF R212 (22K Ω), T202 FOR METER CENTER, T203 FOR DISTORTION MINIMUM 98 MHz L202 CORE FOR MINIMUM DISTORTION. (WHI)

How do I perform the FM Multiplex Alignment?

Note: Set the Function Switch to the “FM” position and the Mode Switch to the “STEREO” position. Connect a Dummy Resistor of 47K-ohms across the output terminals before alignment.

STEP SIGNAL SOURCE CONNECTOR SIGNAL FREQUENCY INDICATOR CONNECTION SET DIAL POINTER TO: ADJUST
1 RF GENERATOR TO FM ANTENNA TERMINALS THROUGH MATCHING NETWORK. (300 OHMS, BALANCED), WITH 1 MV FM STEREO GENERATOR RF LEVEL NO MODULATION. FREQUENCY COUNTER TO J310 CY R325 SO FREQUENCY COUNTER MAY READ 76 KHZ.
2 AND 100% MODULATION (PILOT 9%) STEREO, LEFT (1,000 HZ) VTVM TO RIGHT CHANNEL OUTPUT. 98 MHZ R311 FOR MAXIMUM OUTPUT AND SAME SEPARATION IN BOTH CHANNELS.
3 STEREO, RIGHT (1,000 HZ) VTVM TO LEFT CHANNEL OUTPUT.

How do I perform the AM IF Alignment?

Note: Set the Function Switch to the “AM” position. Connect a Dummy Resistor of 47K-ohms across the output terminals before alignment.

STEP SIGNAL SOURCE CONNECTION SIGNAL FREQUENCY INDICATOR CONNECTION SET DIAL POINTER TO: ADJUST
1 SWEEP GENERATOR TO OSC VARIABLE CAP. 450 KHz MARKER. OSCILLOSCOPE t. T. QUIET POINT ON BAND. T201 FOR MAXIMUM AND SYMMETRIC RESPONSE.

How do I perform the AM RF Alignment?

Note: Set the Function Switch to the “AM” position. Connect a Dummy Resistor of 47K-ohms across the output terminals before alignment. Use the Test Loop as shown in Figure 3 for signal application.

STEP SIGNAL SOURCE CONNECTION SIGNAL FREQUENCY INDICATOR CONNECTION SET DIAL POINTER TO: ADJUST
1 APPLY THE SIGNAL TO THE AM LOOP ANTENNA FROM THE RF GENERATOR, USING THE TEST LOOP, AS PER THE FIGURE 3. 520 KHZ VTVM TO L OR R CHANNEL OUTPUT. TUNING CAPACITOR MINIMUM CLOSED. L102 FOR MAXIMUM OUTPUT.
2 1,639 KHZ TUNING CAPACITOR MAXIMUM OPEN. OSC. TRIM. CAP. FOR MAXIMUM OUTPUT.
3 600 KHZ 600 KHZ AM BAR ANT FOR MAXIMUM OUTPUT.
4 1,400 KHZ 1,400 KHZ ANT. TRIM. CAP. FOR MAXIMUM OUTPUT.
5 REPEAT STEPS 1 TO 4 AS NECESSARY TO OBTAIN MAXIMUM SENSITIVITY.

What are the technical specifications of the Marantz SR225?

AUDIO SECTION

  • Power Output Per Channel (RMS 8 OHMS): 25W
  • Total Harmonic Distortion (at RMS 8 OHMS): 0.3%
  • Damping Factor (8 OHMS): 30
  • Frequency Response:
    • Phono (RIAA): ± 1.0 dB
    • Aux (±2.0 dB): 20 Hz – 20 kHz
  • Signal-to-Noise Ratio:
    • Phono: 65 dB
    • Aux: 80 dB
  • Input Terminals:
    • Phono: Input Sensitivity/Impedance: 2.5 mV/47 kohms
    • Aux: Input Sensitivity/Impedance: 150 mV/25 kohms

FM TUNER SECTION

  • Frequency Range: 87.5 – 108 MHz
  • Usable Sensitivity:
    • DIN Mono (S/N 26 dB, 75 ohms): 3 uV
    • DIN Stereo (S/N 46 dB, 75 ohms): 25 uV
  • Alternate Channel Selectivity (98 MHz): 60 dB
  • Signal-to-Noise Ratio (98 MHz):
    • Unweighted: Mono 66 dB, Stereo 63 dB
    • Weighted: Mono 70 dB, Stereo 65 dB

MW TUNER SECTION

  • Frequency Range: 505 – 1,650 kHz
  • Usable Sensitivity (20 dB S/N 30% Mod., 1 MHz): 300 uV
  • Selectivity: 35 dB

GENERAL

  • Power Requirements: 120V AC 60Hz
  • Power Consumption (at Rated Output, Both Channels Operating): 90W
  • Dimensions:
    • Panel Width: 416 mm
    • Panel Height: 100 mm
    • Depth: 194 mm
  • Weight (Unit alone): 4.9 kg

Specifications and appearance are subject to change for modification without notice.