What are the key safety instructions for the LINEA DOMO DO360A air conditioner?
When using your LINEA DOMO DO360A, always adhere to the following safety precautions:
• Read all instructions carefully and keep the manual for future reference.
• Ensure all packaging materials and promotional stickers are removed before first use. Keep packaging away from children.
• This appliance is intended for household and similar applications. It is not for use with an external timer.
• This appliance can be used by children aged 16 and above and persons with reduced capabilities if supervised. Children younger than 16 should not be near the appliance or its cord.
• Before use, verify that the voltage on the appliance matches your home’s power network.
• Do not let the cord hang over hot surfaces or sharp edges.
• If the cord or plug is damaged, or the appliance malfunctions or is damaged, do not use it. Take it to a qualified service center.
• Unplug the appliance when not in use, before maintenance, or when assembling/disassembling parts. Turn all controls to ‘off’ and grasp the plug to unplug; never pull the cord.
• Do not leave the appliance unattended while operating.
• Do not place the appliance near a gas stove, electrical stove, or other warm surfaces.
• Use the appliance only for its intended domestic purpose on a steady, dry, and level surface. Do not use it outdoors.
• Never immerse the appliance, cord, or plug in water or any other liquid.
• Keep the cord away from sharp edges and hot parts.
• Never place the unit near a stove, fire, or highly inflammable liquids. Do not hit or shake the unit.
• Never cover the air inlet or outlet to prevent overheating.
• Do not splash water on the unit or place it near water.
• Do not place another appliance on the same electrical circuit.
• Never handle the plug with wet hands or touch the unit with bare feet.
• Do not put foreign objects into the openings. Do not use an extension cord.
• After turning the unit off, wait 3 minutes before turning it back on to allow the compressor to restart.
• Place the unit at least 1m away from a TV or radio to prevent disturbance.
• Avoid direct sunlight on the unit to prevent discoloration.
• When moving the unit, ensure the angle is never more than 35°. Never place it upside down.
• Always remove water from the tank before storing.
• Ensure there is at least 30 cm of free space around the unit.
• Never remove fixed parts. Do not use the unit if it has been dropped or damaged.
Are there specific safety warnings for the R290 refrigerant gas in the LINEA DOMO DO360A?
Yes, there are specific warnings for the LINEA DOMO DO360A due to its use of R290 refrigerant gas:
• Thoroughly read all warnings.
• When defrosting and cleaning, only use tools recommended by the manufacturer.
• The appliance must be placed in an area without continuous sources of ignition (e.g., open flames, operating gas or electrical appliances).
• Do not puncture or burn any part of the refrigerant circuit.
• Be aware that refrigerant gases may be odorless.
• The appliance must be installed, used, and stored in a room larger than 11 m².
• This appliance contains a specific amount of R290 refrigerant gas, as indicated on the rating label on the back of the unit.
• R290 is a refrigerant gas that complies with European environmental directives.
• If the appliance is in a non-ventilated area, the room must be designed to prevent the accumulation of refrigerant leaks, which could lead to a fire or explosion risk.
• The appliance should be stored in a way that prevents mechanical failure.
• Any individual working on the refrigerant circuit must have certification from an accredited organization.
• Repairs must be based on the manufacturer’s recommendations and performed under the supervision of a specialist in the use of flammable refrigerants.
• A caution symbol on the unit indicates a risk of fire from flammable materials. If the refrigerant leaks and is exposed to an external ignition source, there is a risk of fire.
What are some energy-saving tips for the LINEA DOMO DO360A?
To use your LINEA DOMO DO360A more efficiently, follow these tips:
• Never use the unit in rooms that are bigger than the recommended room size.
• Make sure the airflow of the unit is not blocked by furniture or other objects.
• Keep curtains closed during the warmest hours of the day.
• Make sure the filters of the air conditioning are always clean.
• Always keep doors and windows closed to keep the cool air inside and the warm air outside.
How do I install the LINEA DOMO DO360A?
For general installation:
• Place the air conditioner on a solid and stable floor to prevent excessive noise and vibrations. The floor must be strong enough to support the appliance’s weight.
• The appliance has small wheels for easy moving. Only move it over a flat and level surface. Be careful when moving it over carpet and never roll it over an object.
• The plug must be connected to a grounded outlet that complies with local standards.
• Mount the cable storage accessory on the back of the unit.
• Ensure there is at least 30 cm of space around the unit and at least 50 cm around the air outlet.
• Make sure the air outlet hose is directed outside and is not bent during use. Keep the opening to the outside as small as possible to prevent warm air from entering.
How do I install the window kit for the LINEA DOMO DO360A?
The air outlet hose must be used in “cool” or “auto” mode. Follow these steps to install the window kit:
1. Place the hose/appliance connector on one side of the air outlet hose and the hose/window adapter connector on the other. Push them onto the hose until they snap into place.
2. Attach the hose to the unit. The side with the hose/appliance connector should be mounted on the air outlet at the back of the appliance. Slide the connector into the holders, ensuring the hook on the connector matches the notch above the air outlet.
3. Place the window adapter in the window opening (horizontally or vertically). Use the provided window seals to close any gaps. Block the window adapter at the desired length using the supplied plug.
4. If desired, you can fix the window with the L-iron and 2 screws.
5. Attach the hose connector to the window adapter.
How do I install the wall kit for the LINEA DOMO DO360A?
The air outlet hose must be used in “cool” or “auto” mode. To install through a wall:
1. Make an opening in the wall the size of the wall adapter (125 mm). Insert the wall adapter into the opening and attach it to the wall using the 4 supplied plugs and screws.
2. Place the hose/appliance connector on one side of the air outlet hose and the hose/wall adapter connector on the other. Push them onto the hose until they snap into place.
3. Attach the hose to the unit. The side with the hose/appliance connector should be mounted on the air outlet at the back of the appliance. Slide the connector into the holders, ensuring the hook matches the notch above the air outlet.
4. Attach the air outlet hose to the wall adapter.
5. When not using the air conditioner, you can close the wall adapter with the cover.
How do I use the functions on the control panel of the LINEA DOMO DO360A?
The control panel has the following touch controls:
• ON/OFF touch: Turns the unit on or off.
• SLEEP touch: Activates sleep mode. The set temperature will increase by 1°C after 30 minutes, and by another 1°C after another 30 minutes. This new temperature is maintained for 7 hours, after which the unit returns to the original setting. This function cannot be used in “fan” or “dry” mode.
• FAN touch: Selects the fan speed. There are four settings: low, medium, high, and auto. The indicator light does not illuminate in auto mode.
• “+” and “-” touch: Adjusts the temperature or the timer setting. Pressing both at the same time switches the display between Celsius (°C) and Fahrenheit (°F).
• MODE touch: Cycles through the functions: AUTO – COOL – DRY – FAN. The corresponding indicator light will turn on.
• TIMER touch: Sets the unit to turn on or off automatically. When the unit is on, pressing this activates the “auto shut off” timer. When off, it activates the “auto on” timer. Use the +/- touches to set the time (up to 24 hours).
• SWING touch: Adjusts the air direction.
• LED Display: Shows the temperature and timer selections. In “dry” or “fan” mode, it shows the room temperature.
What are the different operating modes of the LINEA DOMO DO360A?
You can select the operating mode using the MODE touch on the control panel:
• AUTO function: The air conditioner automatically selects between “cool” or “fan” function based on the room temperature and the set temperature to maintain a stable environment. You cannot select the fan speed in this mode.
• COOL function: The unit cools the air. Use the arrow touches to set the desired room temperature and the FAN touch to set the air speed.
• DRY function: This function dehumidifies the air. You cannot select a temperature or fan speed. Keep windows and doors closed for optimal performance. It is not necessary to install the air outlet hose for this function.
• FAN function: This allows you to use the unit as a fan. Press the FAN touch to select the air speed. The temperature cannot be selected. You do not need to attach the air outlet hose for this function.
How do I use the remote control for the LINEA DOMO DO360A?
General Usage:
• The remote works within 8 meters of the unit. Point it towards the air conditioner. A beep signal confirms transmission.
• Signals can be blocked by curtains, doors, or other materials.
• Keep the remote dry and away from direct sunlight or heat.
• If the infrared sensor on the appliance is in direct sunlight, it may not react to the remote.
Batteries:
• The remote uses 2 AAA (R03/LR3) batteries.
• To install, remove the battery compartment cover, place the batteries according to the + and – indications, and replace the cover.
• Do not mix old and new batteries, or different types of batteries.
• Remove batteries if you won’t use the remote for more than two months.
• NOTE: When you remove the batteries, all selections are deleted and must be reinstalled.
What do the buttons on the remote control for the LINEA DOMO DO360A do?
• ON/OFF BUTTON: Turns the unit on or off.
• ARROW BUTTONS: Sets the temperature. Hold down for 3 seconds to switch between Celsius and Fahrenheit.
• MODE BUTTON: Selects the function: cool – fan – dry – auto. (Note: A heat mode may appear on the remote, but the unit is not equipped with a heat function).
• FAN BUTTON: Selects the fan speed: auto, low, medium, high.
• TIMER ON BUTTON: Sets a delayed start time. Press to activate and repeatedly press to increase the time (up to 24 hours). Pressing ON/OFF cancels all timers.
• TIMER OFF BUTTON: Sets a delayed stop time. Press to activate and repeatedly press to increase the time (up to 24 hours).
• SHORTCUT BUTTON: Press for 3 seconds to save the current settings (mode, temperature, fan speed, sleep setting). A single press will recall these settings.
• SLEEP BUTTON: Activates sleep mode for comfortable night-time temperature and energy savings (for “cool” and “auto” modes only).
• SWING BUTTON: Adjusts the air flow direction.
• FOLLOW ME BUTTON: Activates a function where the temperature is measured at the remote control’s location instead of the unit. The remote sends a signal every 3 minutes. Place the remote where you want the temperature to be optimal.
• LED BUTTON: Turns off all indicator lights on the unit’s display, for example, when using at night. Press again to turn them back on.
How do I drain the water from my LINEA DOMO DO360A?
There are two ways to manage condensation water:
Permanent Drain:
You can use this method during “dry” mode for continuous drainage.
1. Remove the drain plug and the rubber top.
2. Attach the drain hose to the drain.
3. Ensure the water is drained in a safe and permanent way.
Drain Code P1 (Internal Water Tank):
When not using the permanent drain, condensation water is stored in the internal tank. When the tank is full, the unit will beep, display the code P1, and the “cool” or “dry” mode will stop automatically (the fan will continue to operate).
1. Move the unit to a place where you can easily drain the water.
2. Remove the drain plug at the bottom of your unit and drain the water completely.
3. After draining, place the drain plug back on the drain opening securely.
4. Restart the unit. The P1 code should disappear. If it persists, try turning the unit off and on a few times.
How do I clean the LINEA DOMO DO360A?
Always unplug the unit before cleaning. Never use chemical or abrasive products, and never clean with water as it can cause electrocution.
Air Filters:
• The unit contains 2 air filters. Clean them at least every 2 weeks to prevent malfunction due to dust.
• Clean the filters in lukewarm water with a mild detergent.
• Rinse the filters thoroughly and let them air dry completely.
• Once dry, place them back in the unit.
Air Conditioning Body:
• Use a damp, soft cloth with a bit of mild detergent to clean the outside of the unit.
• Make sure the unit is thoroughly dried afterwards.
How should I store the LINEA DOMO DO360A?
To store the unit for a long period, follow these steps:
1. Drain all the water from the appliance.
2. Turn on the unit in “fan” mode for half a day while it is in a heated room. This will dry the unit completely and prevent mold from forming.
3. Turn off the unit, remove the plug from the socket, and remove the batteries from the remote control.
4. Clean the filters and place them back in the unit.
5. Store the unit in a dry, dark place.
What should I do if my LINEA DOMO DO360A is not working or not cooling properly?
If the appliance isn’t working when pressing the on/off touch:
• If the error code P1 is displayed, drain the water from the air conditioning.
• The room temperature may be lower than the selected temperature. Adjust the selected temperature.
If the room is not cool enough:
• The windows and doors may not be closed. Make sure all windows and doors are closed.
• There may be heat sources in the room. Remove all heat sources if possible.
• The air outlet hose may not be connected or could be blocked. Attach the hose and check for blockages.
• The selected temperature may be too high. Adjust the selected temperature.
If the appliance is making too much noise or causing vibrations:
• The floor may not be level or flat. Place the appliance on a flat and level surface if possible.
If your appliance makes a gurgling sound:
• This is normal. The sound is produced by the refrigerant in your appliance.
How should I dispose of the LINEA DOMO DO360A?
The symbol on the product or its packaging indicates that this product should not be treated as household waste. It must be taken to an applicable collection point for the recycling of electrical and electronic equipment. By ensuring correct disposal, you help prevent potential negative consequences for the environment and human health. For more detailed information about recycling, contact your local city office, household waste disposal service, or the shop where you purchased the product.
The packaging is recyclable. Please treat the packaging ecologically.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.