****** Page 1 ****** INSTRUCTION MANUAL- LOAD MANAGER e AUTOMATIC LOAD SHEDDING SYSTEM # : 091-79 MODE’ MODEL- # : 091-79-24 o o File: 1M 091-79-xx reve. Revised By: MFG Date: 10-æa-2013 170 Cherry Avenue indd West Sayville, NY 11796 kussmaul.com a YEAR WARRANTY KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS couNT scan using your mobile device for more information Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com

****** Page 2 ****** INTRODUCTION The 091-79-XX, Load Manager 2, is a device which continuously monitors the voltage of the battery. The unit is field adjustable to other voltages from factory settings. Two output relays are provided. The output relays are capable of switching 30 amperes and both “normally open” and “normally closed” contacts are provided. INSTALLATION AND ADJUSTMENT l. INSTALLATION OF THE LOAD MANAGER 2 Connect the Load Manager 2 to the battery and the loads as illustrated in figure 1. This is a typical circuit; many other variations are possible. It is important to connect the Bat+ and Bat- terminals to that point at which the voltage is to be sensed. II. FIGURE 1, WIRING DIAGRAM LOAD MANAGER OUTPUT, WILL BE DE-ENERGIZED WHEN VOLTAGE GOES BELOW SETPOINT OF 2 TO LOAD, WILL BE ENERGIZEOWHEN VOLTAGE GOES BELOW SETPOINT OF RELAY 2 Fuse + Volts RELAY 2 COM RELAY 1 COM 8AT+ BAT- 1 To Voltage Sense Point Note: Fuse size determined by Load Requirement, 30A Max. 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED AND READY WHEN SECONDS COUNT LOAD MANAGER OUTPUT WILL BE DE-ENERGIZED WHEN VOLTAGE GOES BELOW SETPOINT OF RELAY 1 TO LOAD, WILL BE ENERGIZED WHEN VOLTAGE GOES BELOW SETPOINT OF RELAY 1 Fuse + Volts Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com 3

****** Page 3 ****** Ill. ADJUSTING OF THE LOAD MANAGER 2 The factory adjustment for the Load Manager 2 is for the first relay to be energized. The 2nd relay is energized at a voltage .5 volts lower than relay 1. No separate adjustment is provided for relay 2. To readjust the setpoint, remove the 4 screws and lift offthe cover. Connect a variable voltage source to the battery input terminals and an ohmeter across the normally open contacts of relay 1. Vary the input voltage to the point at which relay 1 just becomes energized. Turn the trimmer resistor RI 00 slightly CCW to lower the setpoint or slightly CW to raise the setpoint. Check the new setting to determine what voltage will cause the relay to be energized. W. FIGURE 2, VOLTAGE ADJUSTMENT 12.0 VOLTS O VOLTAGE TRIMMER RIOO CAUTION The circuit responds very slowly so allow ample time, 15 to 30 seconds for the circuit to respond to voltage changes. This time delay is required to prevent the relay from chattering for small changes in voltage around the setpoint. 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED AND READY WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com 4

****** Page 4 ****** SPECIFICATIONS Model Number 091-79 091-79-24 Input Voltage (Vdc) 10 to 15 20 to 30 Input Relay Deenergized (Amps) .020 .020 Input Relay Energized (Amps) .20 .10 4+25 1.625 Relay Contacts (Amps) 30 30 Weight (lbs) .5 .5 OUTLINE DRAWING 3/16″ 3.50 3.75 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED READY WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com 4

****** Page 5 ****** INSTALLATION RECORD DATE INSTALLED INSTALLED BY VEHICLE IDENTIFICATION VEHICLE OWNER WARRANTY POI-ICY All products of Kussmaul Electronics are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid Kussmaul Electronics shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics products. The purchaser, by the acceptance of the equipment, assumes all liabil- ity for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. Members of Fire and Einergency Manufacturers and Service Members of National fire Protection Association NFPA Members of Fire Apparatus Manufacturers Made in USA 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED AND READY WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com