****** Page 1 ****** FILE: 1M -ga-xx revC DATE: 06-05-201 a INSTRUCTION MANUAL I-OAD MANAGER 1 H UNDER-VOLTAGE DETECTOR RELAY WITH HYSTERESIS LOAD MANAGER 1 H 091ea k.U8SMAUL co. MODEL. #091 -se.xx A BATTERY VOLTAGE MONITOR DETECTS AN UNDER-VOLTAGE CONDITION. 1 70 Cherry Ave. West Sayville, NY 1 1 kussrnaul. corn a YEAR WARRANTY ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT Phone: -587-031 4 Fax: 631 -567-5826 sales@kusemaul.com

****** Page 2 ****** INTRODUCTION: The 091-96-xx LOAD MANAGER 1 H is a device, which continuously monitors the voltage of the battery. The unit is factory set to actuate at 1 2 volts, for 1 2 volt models or 24 volts for 24-volt models, but may be adjusted to other voltages. The output relay is capable of switching 30 amperes, and both a “normally open” and normally closed” contact are provided. INSTALLATION: Connect the Load Manager 1 H to the battery, the load and the fuse as illustrated in figure 1. This is atypical circuit. Other circuit configurations are possible. It is always necessary to connect the Bat+ and Bat- terminals to that point at which the voltage is to be sensed. ADJUSTMENT: The factory setting for the Load Manager 1 H is 12.0 volts (24 v). Field adjustment of the set point is possible. To do this, remove two screws holding down the cover. Note the position of the voltage adjustment trimmer R6. This is the 12-volt (24 v) setting. To decrease the voltage turn counter clockwise. To increase the voltage turn clockwise. Two indicator LED’s are provided adjacent to the terminal strip. When the green LED is lit, the voltage sensed is normal. When the red LED is lit, the voltage is below the set point. The voltage detector can be tested by gradually lowering the system voltage while simultaneously measuring the voltage applied to the input terminals with a precise voltmeter and noting the voltage at which the red LED turns “ON”. The 091-96-xx Load Manager 1 H contains an adjustable high hysteresis feature. With the normal trip point set to 12.0 volts (24.00 volts), the hysteresis circuit maintains the relay energized until the voltage increases above 13.45 volts. This assures thatthe loads being controlled are not energized until the sensed voltage reaches 13.45 volts (26.9 volts). This limits the ON/OFF cycling of the load. The hysteresis may be adjusted using trimmer RI 5. Turning RI 5 CCW will decrease the hysteresis while turning CW will increase. Unless absolutely necessary it is recommended that the hysteresis remain at the factory setting.

****** Page 3 ****** SPECIFICATIONS: Model In ut volta e In ut am s rela off In ut am s rela on Rela contacts am s Case Wei ht o 5.10 4,50 091-96-12 10 to 15 volts D.C. 0.02 Am s 0.1 Am s 30 Am s non-weather roof 4 ounces 3/16′ DIA. o OUTLINE DRAWING 091-96-24 20 to 30 volts D.C. 0.015 Am s 0.05 Am s 30 Am s non-weather roof 4 ounces 2.95 I .55

****** Page 4 ****** The Load connected to this contact will be energized when voltage sensed goes below set-point. Fuse Input Figure 1, Voltage Trimmer N.O. O c BAT- O The load connected to this contact will be de-energized when the voltage sensed goes below the set-point To Voltage Sense point Load Manager 1 Installation Hysteresis Adjustment o 4 KI Figure e, Voltage Adjustment

****** Page 5 ****** INSTALLATION RECORD e WARRANTY Date Installed Installed By Vehicle Identification Vehicle Owner WARRANTY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liabilityfor damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the accep- tance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.