****** Page 1 ****** INSTRUCTION MANUAL- LOAD MANAGER 1 HP Model: 091-167-12 The 091-167-12, Load Manager 1 HP is a small waterproof assembly that monitors a D.C. voltage and operates a relay when the voltage drops below its set point. With the engine running and battery voltage above 12.8 volts, the relay is energized and power is supplied to the loads. With the engine stopped and continuous loads that reduce the battery below +11.5 volts, the relay will drop out and prevent complete discharge of the battery. The relay remains de-energized until the battery voltage returns to +12.8 volts or higher. An optional starter input prevents the relay from dropping out during the cranking cycle if the volt- age prior to cranking was sufficient (+11.5 volts). Note: the starter input is not required for normal operation if cranking shutdown protection is not required Size for 25% H ghar Than Actua Load Batter/ Fuse Starter Specifications: Input Voltage: +12 Volt Nominal Relay Pull In: 12.8 +/- 0.1 Volts Relay Drop Out : 11.5 +1-0.1 Volts Relay Contact Rating: 75 Amperes D.C. 75 Amp Rday Warranty: 3 years 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com file: OBI -167-12_revA Revised By: PSS/JRN Date: 09-20-1 e KUSSMAUL ELECTRONICS ENERGIZED AND READY WHEN SECONDS COUNT Radio & Computer Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com