Free English KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

What type of batteries is the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 designed for?

The charger is calibrated specifically for the ODYSSEY requirement of 14.7 volts in the bulk/absorption range and 13.6 volts in the float mode. It is designed for ODYSSEY AGM Batteries. CAUTION: DO NOT USE TO CHARGE A NORMAL LEAD ACID BATTERY.


What are the key features of the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

The features include:

Completely automatic operation, charges battery on demand

Output Voltage regulated, eliminates overcharging battery

Output, current limited to protect charger from overloading

A 5-LED display indicating charge state and faults

Reverse polarity protection


How should the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 be installed?

The charger should be installed in an area with adequate ventilation. Follow these steps:

1. Mount the charger using the four holes provided.

2. Connect wiring from the battery to the output terminal strip.

3. Double check battery wiring. Verify that the battery voltage appears at the charger output terminals.


How does the “Bulk Charge” stage work on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

A discharged battery is recharged at a constant current (bulk charge) until its voltage reaches an overcharge level of 2.45 volts per cell. At this time the charger will switch to Finish Charge. The battery accepts 75-85% of its capacity during bulk charge.


What happens during the “Absorption” or “Finish Charge” stage on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

The overcharge voltage reached in the bulk stage is maintained constant at 2.45 volts per cell for eight (8) hours.


How does the “Float Charge” stage operate on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

After an eight (8) hour Finish Charge Stage has completed, the charger will “Time Out” to a Float Charge Stage where the battery under charge will receive a 13.6VDC Float Charge or 2.26VDC per cell. The battery is maintained at full charge during Float Charge, and the green indicator labeled “Battery Charged” AND red indicator labeled “Time Out” will be illuminated.


What conditions trigger the battery fault indicator on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

A battery fault indicator is provided to indicate the absence of a battery, a battery connected with reverse polarity, or a battery with an open circuit terminal voltage of less than 1.35 volts per cell.


What are the technical specifications for the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

Input Power: 115VAC, 60Hz, 4.7Amps

Input Over Current Protection: Fuse; 8Amp, Slow-Blow

Output Power: 12 to 14.7VDC, 20Amperes Current Limited

Charge Indicator: 25Amperes

Weight: 22 Pounds


What do the different mode indicators signify on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?

Battery Fault: Red

Time Out: Red

Bulk Charge: Yellow

Finish Charge: Yellow

Battery Charged: Green

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.