What type of batteries is the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 designed for?
The charger is calibrated specifically for the ODYSSEY requirement of 14.7 volts in the bulk/absorption range and 13.6 volts in the float mode. It is designed for ODYSSEY AGM Batteries. CAUTION: DO NOT USE TO CHARGE A NORMAL LEAD ACID BATTERY.
What are the key features of the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
The features include:
Completely automatic operation, charges battery on demand
Output Voltage regulated, eliminates overcharging battery
Output, current limited to protect charger from overloading
A 5-LED display indicating charge state and faults
Reverse polarity protection
How should the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20 be installed?
The charger should be installed in an area with adequate ventilation. Follow these steps:
1. Mount the charger using the four holes provided.
2. Connect wiring from the battery to the output terminal strip.
3. Double check battery wiring. Verify that the battery voltage appears at the charger output terminals.
How does the “Bulk Charge” stage work on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
A discharged battery is recharged at a constant current (bulk charge) until its voltage reaches an overcharge level of 2.45 volts per cell. At this time the charger will switch to Finish Charge. The battery accepts 75-85% of its capacity during bulk charge.
What happens during the “Absorption” or “Finish Charge” stage on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
The overcharge voltage reached in the bulk stage is maintained constant at 2.45 volts per cell for eight (8) hours.
How does the “Float Charge” stage operate on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
After an eight (8) hour Finish Charge Stage has completed, the charger will “Time Out” to a Float Charge Stage where the battery under charge will receive a 13.6VDC Float Charge or 2.26VDC per cell. The battery is maintained at full charge during Float Charge, and the green indicator labeled “Battery Charged” AND red indicator labeled “Time Out” will be illuminated.
What conditions trigger the battery fault indicator on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
A battery fault indicator is provided to indicate the absence of a battery, a battery connected with reverse polarity, or a battery with an open circuit terminal voltage of less than 1.35 volts per cell.
What are the technical specifications for the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
Input Power: 115VAC, 60Hz, 4.7Amps
Input Over Current Protection: Fuse; 8Amp, Slow-Blow
Output Power: 12 to 14.7VDC, 20Amperes Current Limited
Charge Indicator: 25Amperes
Weight: 22 Pounds
What do the different mode indicators signify on the KUSSMAUL AUTO CHARGE 3 STEP 091-120-12E-20?
Battery Fault: Red
Time Out: Red
Bulk Charge: Yellow
Finish Charge: Yellow
Battery Charged: Green