FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF DOCUMENT.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF USER GUIDE.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF USER MANUAL.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF OWNER GUIDE.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF OWNER MANUAL.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF REFERENCE GUIDE.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF REFERENCE MANUAL.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH KINETIK WELLBEING JPD-FR409-BT (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD KINETIK WELLBEING JPD-FR409-BT (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is included in the package with the KINETIK WELLBEING JPD-FR409-BT?
| No. | Name | Quantity |
|---|---|---|
| 1 | Infrared Thermometer | 1 |
| 2 | Pouch | 1 |
| 3 | Battery (AAA) | 2 |
| 4 | Instruction Manual | 1 |
What safety precautions should I follow when using the KINETIK WELLBEING JPD-FR409-BT?
Please observe the following safety precautions when using your KINETIK WELLBEING JPD-FR409-BT thermometer:
• Take care of the temperature probe lens, which is fragile.
• Dispose used batteries with care. To protect the environment, you are recommended to send the used batteries to a designated collection point.
• Remove the batteries if the thermometer will not be used for more than two months.
• Do not immerse the thermometer in water or expose it to direct sunlight.
• Do not subject the thermometer to vibration or impact.
• The normal body temperature varies from person to person. Tracking a person’s body temperature will help determine whether they have fever.
• Do not take body temperature readings within 20 minutes after you do physical exercises or get excited.
• Clean the thermometer probe after each use.
• Do not use the thermometer on newborns or for continuous temperature monitoring purposes.
• Do not use the thermometer for purposes that are not specified in this User’s Manual. Follow the instructions in the “Measurement Process” chapter and carefully operate the thermometer when measuring children’s temperature.
• Do not immerse the thermometer in water or other liquid, as it is not waterproof. Clean and disinfect the thermometer as described in the “Cleaning and Disinfection” chapter.
• Do not touch the tip of the temperature probe, on which a precise temperature sensor resides.
• Keep the temperature probe clean to make sure accurate readings.
• Before measuring the temperature from the ear canal, clean the earwax, if any.
• The ambient temperature must not be extremely high or low. To make sure accurate readings, keep the thermometer under room temperature for more than 30 minutes before use.
• Do not use the thermometer under an ambient temperature higher than 40°C (104°F) or lower than 10°C (50°F), which is beyond the operating temperature range of the thermometer.
• Risk of pollution! The user is recommended to send the overdue thermometer to local garbage disposal site or send it back to us.
• 2 AAA batteries of 1.5V are the only replaceable accessories of the thermometer. Please do not use the batteries of other voltages or specifications.
What are the important warnings for using the KINETIK WELLBEING JPD-FR409-BT?
Please take note of the following warnings:
• Do not force the temperature probe of the thermometer into an ear canal. Otherwise, the ear canal may get injured.
• Keep the thermometer out of the reach of children.
• The result may be inaccurate if you use the overdue thermometer.
• The thermometer is not intended to diagnose or treat any health problem or disease. The measurement results are for reference only.
• It is dangerous to make a self-diagnosis or self-treatment based on the obtained measurement results. For such purposes, please consult a doctor.
• Do not charge an alkaline dry-cell battery or throw it in fire. Otherwise, the battery may explode.
• Do not disassemble the thermometer or attempt to repair it. Otherwise, the thermometer may be damaged permanently.
• Do not take temperature measurements on body parts other than forehead and ears. Otherwise, the temperature readings may be inaccurate.
• During measurement, do not use a mobile phone or any other device that may cause electromagnetic interference.
• Do not use the thermometer in an environment where flammable anesthetic mixture with air or with oxygen or nitrous oxide is available.
What do the symbols on the KINETIK WELLBEING JPD-FR409-BT and its packaging mean?
| Symbol | Description |
|---|---|
| Type BF applied part symbol | Type BF applied part |
| Attention symbol | Attention must be paid. |
| Prohibited action symbol | The action is prohibited. |
| Manufacturer symbol | Information about the manufacturer. |
| Date of Manufacture symbol | Date of Manufacture and Made in China |
| Read instructions symbol | Read the instructions (actual symbol colours are white on a blue background) |
| CE 0482 | This product complies with the MDD93/42/EEC requirements |
| EC REP | Authorized European Representative |
| WEEE symbol | Waste electrical materials should be sent to a dedicated collection point for recycling. |
| IP22 | The degree of protection against harmful ingress of water and particulate matter |
| LOT | Lot Number |
| SN | Symbol for “SERIAL NUMBER” |
| Warning symbol | A personal injury or damage to the thermometer may occur if the thermometer is not used correctly. |
| Attention symbol | Inaccurate reading or damage to the thermometer may occur if the thermometer is not used correctly. |
What are the normal body temperature ranges?
The temperature measured at different parts of the body may differ slightly. The normal body temperature range slightly varies with age and gender.
| Body Site | Normal Temperature Range |
|---|---|
| Forehead | 34.7°C-37.3°C (94.5°F-99.1°F) |
| Eardrum | 35.8°C-38.0°C (96.4°F-100.4°F) |
| Mouth | 35.5°C-37.5°C (95.9°F-99.5°F) |
| Armpit | 34.7°C-37.3°C (94.5°F-99.1°F) |
| Rectal | 36.6°C-38.0°C (97.9°F-100.4°F) |
What is the intended use of the KINETIK WELLBEING JPD-FR409-BT?
The KINETIK WELLBEING JPD-FR409-BT Smart Ear & Forehead Thermometer is intended for the measurement of human body temperatures. The forehead mode is indicated for use by people of all ages and the eardrum mode is indicated for use by people above three months old.
What are the main features of the KINETIK WELLBEING JPD-FR409-BT?
Good safety
• Passive infrared receiving technology.
Easy operation
• Ergonomic design
• One button measurement
Quick measurement
• 1-second measurement
High accuracy
• Advanced infrared temperature sensor, with high sensitivity
• High accuracy with automatic temperature calibration
Diverse functions
• 20 reading recalled
• Fever alert
• Switching between °C and °F
• Automatic power-off, power saving
Extensive application scope
• Forehead temperature measurement applicable to all age groups
• Ear temperature measurement applicable to children older than three months, adults, and the elderly
Child mode
• This mode is recommended for people under 12 years of age.
What are the parts of the KINETIK WELLBEING JPD-FR409-BT thermometer and its display?
The main components of the thermometer are:
1. LCD display screen
2. Indicator
3. Power button / Measure button
4. Adult mode / Child mode switch
5. Mode button (Forehead / Ear / Object)
6. Probe (take off the cover when measuring the ear temperature)
7. Unit switch button (°C/°F)
8. Probe cover (put the cover on when measuring the forehead temperature)
9. Memory button / Sound switch
10. Battery cover
The display screen shows the following information:
1. Object temperature mode
2. Forehead temperature mode
3. Child mode
4. Ear temperature mode
5. Mute / un-mute
6. Fahrenheit / Celsius degrees
7. Low battery
8. Memory recall
9. Temperature value
How do the sounds and indicator colors work on the KINETIK WELLBEING JPD-FR409-BT?
| Range | Sounds | Indicator color |
|---|---|---|
| Forehead temperature (Adult / Child) | ||
| 22.0°C-37.5°C / 71.6°F-99.5°F | A long beep | Green |
| 37.6°C-43°C / 99.6°F-109.4°F | 3 short double beeps | Red |
| Ear temperature (Adult / Child) | ||
| 34.0°C-37.5°C / 93.2°F-99.5°F | A long beep | Green |
| 37.6°C-43.0°C / 99.6°F-109.4°F | 3 short double beeps | Red |
| Object temperature | ||
| 0°C-100°C / 32.0°F-212°F | A long beep | Green |
Note: A green indicator and long beep indicate a normal temperature. A red indicator and 3 short double beeps indicate your body temperature is a little high and you may have a fever. Please consult your doctor if you are not sure.
How do I measure ear temperature with the KINETIK WELLBEING JPD-FR409-BT?
1. Take off the probe cover.
2. Press and release the Power button for 1 second to power on the thermometer.
3. Press the Mode button to enter Ear mode. The “Ear” symbol will be displayed on the screen.
4. Switch to the adult or child measurement mode using the side adult/child switcher according to your needs.
5. Insert the temperature probe into the ear canal.
• For children under 1 year: Pull the ear straight back.
• For children aged 1 year to adult: Pull the ear up and back to make sure the ear canal is straight.
6. Press and release the Measure button to start the measurement. The ear temperature reading will be displayed on the screen instantly.
Note: Do not force the thermometer into the ear canal. Otherwise, the ear canal may get injured. Be careful when taking temperature on a child, whose ear canal is small.
How do I measure forehead temperature with the KINETIK WELLBEING JPD-FR409-BT?
1. Put the cover on the probe.
2. Press and release the Power button for 1 second to power on the thermometer.
3. Press the Mode button to enter Forehead mode. The “Head” symbol will be displayed on the screen.
4. Switch to the adult or child measurement mode using the side adult/child switcher according to your needs.
5. Point the thermometer to the sides of the forehead, about 0″ to 1″ (1-3cm) away from the skin surface.
6. Press and release the Measure button. The temperature will be displayed on the screen.
7. If no activity is detected, the thermometer will power off automatically in 10 seconds.
How do I measure object temperature with the KINETIK WELLBEING JPD-FR409-BT?
1. Put the cover on the probe.
2. Press and release the Power button for 1 second to power on the thermometer.
3. Press the Mode button to enter Object mode. The “House” symbol is displayed on the screen.
4. Point the thermometer to the center of the object, about 0″ to 1″ (1-3cm) away from the object surface.
5. Press and release the Measure button. The temperature will be displayed on the screen.
6. If no activity is detected, the thermometer will power off automatically in 10 seconds.
What do the ‘Hi’ and ‘Lo’ messages on the KINETIK WELLBEING JPD-FR409-BT display mean?
These messages indicate that the temperature reading is outside the measuring range.
Hi:
• In Ear mode, a temperature reading of more than 43.0°C (109.4°F).
• In Forehead mode, a temperature reading of more than 43°C (109.4°F).
• In Object mode, a temperature reading of more than 100°C (212.0°F).
When ‘Hi’ is displayed, there will be long beeps and the indicator light will be red.
Lo:
• In Ear mode, a temperature reading of less than 34.0°C (93.2°F).
• In Forehead mode, a temperature reading of less than 22.0°C (71.6°F).
• In Object mode, a temperature reading of less than 0°C (32.0°F).
When ‘Lo’ is displayed, there will be long beeps and the indicator light will be red.
How do I recall saved temperature readings and clear the memory on the KINETIK WELLBEING JPD-FR409-BT?
Recall Memories:
1. In a power-on state, press the Memory button to enter the memory mode.
2. When the Memory button is released, ‘1’ (representing the newest data) will be shown, followed by the recorded reading.
3. Press the Memory button again to view the next recorded data (‘2’, etc.).
4. A maximum of 20 temperature readings can be recalled. When the maximum number is exceeded, the oldest memory data will be overwritten.
Clear Memory Data:
To clear all memory data, remove the 2 dry batteries and then re-install them.
How do I switch between mute and un-mute on the KINETIK WELLBEING JPD-FR409-BT?
1. In the power-on state, press and hold the sound switch button for about 2 seconds to switch the sound on or off.
2. When the sound is turned on, it will beep once. The mute symbol will be displayed when the sound is off.
3. The mute symbol is displayed in Mute mode and disappears in Un-mute mode.
How do I switch between Celsius (°C) and Fahrenheit (°F) on the KINETIK WELLBEING JPD-FR409-BT?
1. In the power off state, remove the battery cover.
2. Toggle the °C/°F unit switch in the battery compartment to switch the toggle device.
3. Toggle the switch upwards for °C and downwards for °F.
What do the error messages ‘Er1’ and ‘ErC’, or a low battery symbol mean on the KINETIK WELLBEING JPD-FR409-BT?
Er1: This indicates the ambient temperature is higher than 40.0°C (104.0°F) or lower than 10.0°C (50.0°F). The device will give long beeps and the indicator light will be red.
ErC: This indicates an error occurred when data was being read from or written to the memory, or the temperature correction is not complete. The device will give long beeps and the indicator light will be red.
Low battery symbol: This will appear on the display when the battery voltage is lower than 2.5V ± 0.1V. Please replace the batteries.
What should I do after taking a measurement with the KINETIK WELLBEING JPD-FR409-BT?
1. After each measurement, you can enter the recall mode to query earlier temperature readings.
2. After each measurement, clean the temperature probe with a soft cloth, and put the thermometer in a dry and well-ventilated place.
Notes:
• The thermometer is suitable for an indoor environment without strong air convection.
• Make sure that the ear canal is clean and dry before starting a measurement.
• Do not hold the thermometer for a long time, as it is sensitive to the ambient temperature.
• Make sure the sense head is free of foreign matters before use.
• Make sure the forehead has no sweat and no hairs covered before measuring forehead temperature; otherwise, the result could be incorrect.
• Avoid intense emotion or strenuous exercises before measuring.
• After measuring the data once, you should wait for the indicator to turn off and measure the next data.
How do I replace the batteries in the KINETIK WELLBEING JPD-FR409-BT?
1. Slide the battery cover off along the marked direction and take it off.
2. Insert the two AAA batteries into the compartment according to the stated polarities.
3. Ensure the batteries are installed correctly. Otherwise, the thermometer may be damaged.
4. If the low-battery symbol is displayed on the screen, replace the batteries.
5. Batteries of the same type should be used. Dispose of used batteries in accordance with local environmental policies.
Note: The thermometer is shipped with batteries. First open the battery cover, then remove the insulating piece.
How do I connect the KINETIK WELLBEING JPD-FR409-BT to a smartphone via Bluetooth?
1. Download the Temperature Diary by MedM app or the MedM Health app from the App store or Google Play.
2. Install the app and register an account.
3. Enable Bluetooth and the MedM app on your smart device. Make sure both Bluetooth and app are ON when pair-up is proceeding.
4. In the app, select the menu in the top left corner of the screen. Then select My Devices.
5. At the bottom of this screen, select Add New. The app will automatically start scanning for a new device.
6. While the scan is underway turn on your thermometer.
7. Ensure that batteries have been inserted into thermometer before doing so.
8. When detected select the Kinetik Thermometer.
9. Once selected you will be asked if you would like to receive data automatically. To transmit and store each reading automatically you will need to select Yes on this screen. If you select No you will need to manually input your results.
How should I clean and disinfect the KINETIK WELLBEING JPD-FR409-BT?
Cleaning:
Recommended detergents:
• Medical detergents
• Home use mild detergents
Cleaning steps:
1. Take the batteries out before cleaning.
2. Clean the temperature probe with a soft cloth. Clean the lens of the temperature probe with a cotton swab.
3. Wipe the thermometer body with a slightly damp soft cloth.
Disinfection:
Recommended disinfectants:
• Isopropyl alcohol solution (concentration: 70%)
• Medicinal alcohol (concentration: 75%)
• Sodium hypochlorite solution (concentration: 3%)
Disinfecting steps:
1. Wet the clean soft cloth with a small quantity of disinfectant, wipe the thermometer and quickly dry it.
2. Disinfect the thermometer body and the area around the temperature probe with a cloth slightly moistened with 75% medical alcohol.
Important:
• Do not use hot steam or ultraviolet radiation for disinfection.
• Clean and disinfect under temperature of +10°C~+40°C (50°F-104°F), relative humidity of 15%~85%RH (no condensation) and barometric pressure of 86kPa~106kPa.
• Keep water out off the lens during cleaning. The lens may be damaged or scratched if cleaned with a hard object.
• Do not clean with corrosive cleansers. Do not immerse any part of the thermometer into liquid.
What are the maintenance instructions for the KINETIK WELLBEING JPD-FR409-BT?
1. Ensure the safety of the thermometer, and check weekly for potential safety hazards, e.g. whether the lens is broken, the shell has cracks and the sensing head is polluted. Do not use a thermometer with potential safety hazards.
2. After each use, clean the temperature probe as described in the “Cleaning and Disinfection” chapter.
3. Store the thermometer in a dry, dust-free, and well-ventilated place. Ensure it is not exposed to sunlight and that storage and transportation environments meet the requirements.
4. Check regularly whether safety risks exist.
5. Remove the batteries if the thermometer will not be used for more than two months.
How can I troubleshoot common issues with the KINETIK WELLBEING JPD-FR409-BT?
| Problem | Possible Cause | Solution |
|---|---|---|
| The thermometer fails to power on. | Low battery | Change the batteries. |
| Polarities of the batteries are reversed. | Make sure that the batteries are installed correctly. | |
| The thermometer is damaged. | Contact the manufacturer. | |
| “Er1” is displayed. | The ambient temperature is lower than 10°C (50.0°F) or higher than 40°C (104°F). | Take a measurement under an ambient temperature between 10°C (50.0°F) and 40°C (104°F). |
| The temperature reading is lower than the typical body temperature range. | The lens of the temperature probe is dirty. | Clean the lens using a cotton swab. |
| The thermometer probe is not aligned to the eardrum. | Reposition the thermometer probe so that it is aligned to the eardrum. | |
| The thermometer is used within 30 minutes after being taken from a cold environment. | Wait for more than 30 minutes after the thermometer is moved into the measurement environment. | |
| The temperature reading is higher than the typical body temperature range. | The temperature probe is damaged. | Contact the manufacturer. |
What are the technical specifications of the KINETIK WELLBEING JPD-FR409-BT?
| Product Name | Infrared Thermometer |
| Product Model | JPD-FR409-BT |
| Power Supply Mode | Internal power supply |
| Operating Voltage | DC 3V |
| Battery Model | AAA x 2 |
| Battery Life | Alkaline dry battery for around 20,000 measurements |
| Operating Mode | Continuous operating |
| Display | Segment LCD |
| Measure time | About 1 second |
| Latency Time | About 3 second |
| Measuring Range | Forehead mode: 22.0°C-43.0°C (71.6°F-109.4°F) Ear mode: 34.0°C-43.0°C (93.2°F-109.4°F) Object mode: 0.0°C-100.0°C (32.0°F-212.0°F) |
| Accuracy (Laboratory) | Forehead: ±0.2°C (36.0°C-39.0°C); ±0.3°C (22.0°C-36.0°C / 39.0°C-43.0°C); Ear mode: ±0.2°C (36.0°C-39.0°C); ±0.3°C (34.0°C-36.0°C / 39.0°C-43.0°C); Object mode: ±1.0°C / ±2.0°F |
| Resolution | 0.1°C (0.1°F) |
| Memory | 20 temperature readings |
| Low-battery Alert | The low-battery symbol is displayed if the power voltage is lower than 2.5V±0.1V |
| Automatic Power-off | The thermometer automatically powers off if it is not used in 10±1 seconds. |
| Outer dimensions (mm) | 155.2×39.6×49.1mm |
| Weight (g) | Thermometer (with batteries): 101 g |
| Operating Environment | Temperature: 10°C-40°C (50°F-104°F) Humidity: 15%-95% RH, non-condensing Atmospheric pressure: 86 – 106 kPa |
What is the security class of the KINETIK WELLBEING JPD-FR409-BT?
• Type of protection against electric shock: internally powered equipment.
• Degree of protection against electric shock: Type BF applied part.
• Degree of protection against ingress of water: IP22
• Safety degree of using in flammable anesthetic gas blending with air oxygen or nitrous oxide: Non-AP/APG
• No application parts of the thermometer prevents defibrillation charge effect.
• No application parts of the thermometer output signal.
• The thermometer is impermanent installed device.
What are the storage and transportation requirements for the KINETIK WELLBEING JPD-FR409-BT?
The thermometer can be transported using general transportation tools. Severe vibration, shock, or rain must be avoided during transportation. The thermometer must be packaged and then stored in a well-ventilated room without corrosive gas. The storage and transportation environment must meet the following conditions:
• Ambient temperature: -20°C to +50°C (-4°F to 122°F)
• Relative humidity: 15%-95% R.H. (non-condensing)
• Atmospheric pressure: 50-106 kPa
CLICK HERE TO DOWNLOAD KINETIK WELLBEING JPD-FR409-BT (01) PDF DOCUMENT