FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF DOCUMENT.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF USER GUIDE.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF USER MANUAL.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF OWNER GUIDE.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF OWNER MANUAL.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF REFERENCE GUIDE.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF REFERENCE MANUAL.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH JABLOTRON JA-153M-GR (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD JABLOTRON JA-153M-GR (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the basic installation procedure for the JABLOTRON JA-153M-GR?
During installation of the JABLOTRON JA-153M-GR, if possible, avoid placing the device directly onto metal surfaces which may negatively impact the device’s ability to communicate with the system.
Two types of magnets are supplied with the detector: A ferrite magnet in plastic housing (A) and a ring magnet (B).
The basic procedure is as follows:
1. Open the device cover by pressing the housing tab (2).
2. Mount the device’s backplate onto a chosen location.
3. Screw the selected magnet onto a moving part, e.g., a door leaf. The bottom edge of the ferrite magnet plastic must coincide with the bottom edge of the detector housing. It is recommended to use a special non-magnetic screw (included in the package) to attach the ring magnet.
4. Proceed according to the control panel installation manual:
a. In the F-Link software, select the required position in the Devices window and launch the enrolment mode by clicking on the Enrol option.
b. Insert the battery (mind the correct polarity). The enrolment signal is transmitted when the battery is inserted into the detector.
5. Close the detector cover.
6. In order to comply with norms, the front cover must be secured with the supplied locking screw (1).
7. Configure the detector by following the Internal settings chapter in this manual.
Notes:
The JABLOTRON JA-153M-GR detector can also be enrolled into the system by entering its serial number (5) into the F-Link software. You can find the sticker with the serial number/bar code, located on the battery holder.
How does the JABLOTRON JA-153M-GR communicate with the system?
The JABLOTRON JA-153M-GR detector uses bi-directional asynchronous communication which allows changing the internal settings remotely and saving battery capacity simultaneously.
After enrolment to the system, the detector operates in an accelerated mode, until the service mode is exited (but no longer than 24 h). In this mode, the detector checks every 90s whether the system is still in service mode or if new settings should be taken over.
In service mode, the detector communicates once every 19 minutes or with each activation. Therefore, when switching from operational mode to service mode, it can take up to 19 minutes for the detector to recognize control panel status or internal settings change. This period can be reduced by activating the detector or its tamper sensor.
How can I configure the internal settings of the JABLOTRON JA-153M-GR?
The internal settings for the JABLOTRON JA-153M-GR are configured by the F-Link software – Devices tab. Use the Internal settings option on the detector position. A dialog will appear in which the detector functions can be set:
LED indication: On/Off
Pulse mode: Only activations are transmitted to the system
Detection of external magnetic field: When switched on, the detector will analyze its surrounding magnetic field and in case of its disturbance (e.g. by an external magnet) the detector will declare Input Activation and a Fault. The function brings higher protection of the object.
Please note: It is not necessary to wait 90s (or 19 min) until the detector confirms delivery of the new setting, when changes are applied. The system remembers the requested change and forwards the new settings to the detector during the next period of regular communication.
How do I calibrate the external magnetic field detection on the JABLOTRON JA-153M-GR?
For the correct function of the external magnetic field detection on the JABLOTRON JA-153M-GR, it is necessary to calibrate the detector to the nominal value of the magnetic field. You can use the Calibration button in the F-Link software to start the process.
Warning: When the external magnet detection function is switched on, the window or door can only be opened in the direction in which the magnet movement has been calibrated. Otherwise, the detector will declare a Fault simultaneously with the Activation. Therefore, this function cannot be used for windows or doors that are opened in multiple ways (opening, tilting).
To start calibration from the periphery:
The system must be in Service mode, then Activate tamper contact (open the plastic cover) and within 5 seconds deactivate the tamper contact (close the plastic cover). This procedure will enable calibration directly from the periphery, with indication as described below from point 3 (inclusive). The Yellow LED will not be lit when calibration is started from the detector (it is only lit if the peripheral has an open internal setting in the F-Link). Calibration can be terminated by activating the tamper contact (open the plastic cover).
Calibration procedure in F-Link + optical indication:
1. LED Off = the device waiting for connection. To continue, activate and deactivate the magnet (open and close the window/door).
2. Yellow LED on = detector has established a connection. Start calibration to continue.
3. Activate the detector in order to confirm presence of the magnet. The LED indicates yellow with the red LED regularly flashing twice. Please return the magnetic detector into its un-activated state.
4. Yellow LED on + rapid flashing of red LED = magnetic detector calibration takes place for approx. 4 s.
5. Yellow LED on + slow flashing red LED = detector is ready to continue calibration. To continue, activate the detector by opening and closing the window/door. Confirmation of the detector calibration will be indicated by the red LED lighting up for approx. 1 s. Then the red LED will go out and the setting status will change to complete, the yellow LED remains lit.
What are the activation and deactivation distances for the JABLOTRON JA-153M-GR with the supplied ferrite magnet?
The following tables show distance values for activation and deactivation of the JABLOTRON JA-153M-GR detector when using the supplied ferrite magnet. Please note that values may vary when used with other permanent magnets.
Table 1: Distances for activation/deactivation of a detector installed on non-magnetic surface.
| Axis | X | Y | Z |
|---|---|---|---|
| Activation distance (mm) | 11 | 10 | 23 |
| Deactivation distance (mm) | 8 | 8 | 18 |
Table 2: Distances for activation/deactivation of a detector installed on magnetic surface.
| Axis | X | Y | Z |
|---|---|---|---|
| Activation distance (mm) | 9 | 10 | 25 |
| Deactivation distance (mm) | 7 | 8 | 20 |
How do I replace the battery in the JABLOTRON JA-153M-GR?
The system sends a report automatically when the battery in the JABLOTRON JA-153M-GR is low. Remember to switch the system to Service mode before changing the batteries (otherwise a tamper alarm will be triggered). Check the right function of the detector after battery replacement.
What are the technical specifications for the JABLOTRON JA-153M-GR?
| Power | 1x alkaline battery, type: AAA (LR03, 1.5 V / 1.2 Ah) Please note: Battery is not included. |
| Typical lifetime of battery | about 2 years (max. 10 activation daily) |
| LowBatt state | <0.95 V |
| Quiescent current consumption | 50 μA |
| Maximum current consumption | 30 mA |
| Communication frequency | 868.1 MHz, JABLOTRON protocol |
| Maximum radio-frequency power (ERP) | <25 mW |
| Communication range | approx. 500 m (open area) |
| Dimensions transmitter part | 20 x 86 x 20 mm |
| Dimensions magnet part | 16 x 55 x 15 mm |
| Weight (without battery) | 25 g |
| Classification | security grade 3 / environmental class II (according to EN 50131-1) |
| Operational environment | indoor general |
| Operating temperature range | -10 °C to +40 °C |
| Average operating humidity | 75% RH, non-condensation |
| Certification body | Trezor Test s.r.o. (no. 3025), Kiwa Nederland b. v. |
| Complies with | EN 50131-1, -2-6, -5-3, -6, ETSI EN 300 220-2, T 031, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000 |
| Can be operated according to | ERC/REC 70-03 |
CLICK HERE TO DOWNLOAD JABLOTRON JA-153M-GR (01) PDF DOCUMENT