FREE ENGLISH INFICON VGC094 (01) PDF DOCUMENT.
FREE ENGLISH INFICON VGC094 (01) PDF USER GUIDE.
FREE ENGLISH INFICON VGC094 (01) PDF USER MANUAL.
FREE ENGLISH INFICON VGC094 (01) PDF OWNER GUIDE.
FREE ENGLISH INFICON VGC094 (01) PDF OWNER MANUAL.
FREE ENGLISH INFICON VGC094 (01) PDF REFERENCE GUIDE.
FREE ENGLISH INFICON VGC094 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH INFICON VGC094 (01) PDF REFERENCE MANUAL.
FREE ENGLISH INFICON VGC094 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH INFICON VGC094 (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD INFICON VGC094 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the intended use of the INFICON VGC094?
Depending on the options chosen, the INFICON VGC094 can measure total pressure from atmosphere to 10⁻¹¹ mbar. It can trigger a number of pressure-dependent functions to control and monitor vacuum devices and processes. The instructions contained in this document must be strictly followed.
What is included in the scope of delivery for the INFICON VGC094?
The scope of delivery consists of the following parts:
• 1 Control Unit
• 1 Power cord
• 1 Accessories kit containing:
– 4 collar screws and synthetic nipple
– 1 rubber strip
– 2 self-adhesive rubber feet
– 4 banana plugs, 2 mm, red
– 4 banana plugs, 2 mm, black
– 1 screwdriver, 2 mm
• 1 Supplement with QR code
What are the personnel qualifications required to operate the INFICON VGC094?
All work described in the manual may only be carried out by skilled personnel who have suitable technical training and the necessary experience or who have been instructed by the end-user of the product.
How do I perform a rack installation for the INFICON VGC094?
The unit is designed for installation into a 19″ rack chassis adapter according to DIN 41 494. To reduce mechanical strain on the front panel, it is preferable to equip the rack chassis adapter with a guide rail.
Step 1. Secure the rack adapter in the rack frame. Ensure the maximum admissible ambient temperature is not exceeded and air circulation is not obstructed.
Step 2. Slide the INFICON VGC094 into the rack chassis adapter.
Step 3. Fasten the adapter panel to the rack chassis adapter using the screws supplied with the VGC094.
How do I install the INFICON VGC094 in a control panel?
For mounting the INFICON VGC094 into a control panel, a cut-out of 139 mm x 127 mm is required. To reduce mechanical strain, it is preferable to support the unit.
Step 1. Slide the VGC094 into the cut-out of the control panel.
Step 2. Secure it with four M3 or equivalent screws.
Ensure the maximum admissible ambient temperature is not exceeded and air circulation is not obstructed.
How do I set up the INFICON VGC094 as a desk-top unit?
The INFICON VGC094 may also be used as a desk-top unit. For this purpose, two self-adhesive rubber feet and a slip-on rubber bar are supplied with it.
Step 1. Stick the two supplied rubber feet to the rear part of the bottom plate.
Step 2. Slip the supplied rubber bar onto the bottom edge of the front panel.
Select a location where the admissible maximum ambient temperature is not exceeded (e.g. due to sun irradiation).
How do I connect the INFICON VGC094 to the mains power?
Use only a 3-conductor power cable with protective ground. The mains power connector may only be plugged into a socket with a protective ground. The protection must not be nullified by an extension cable without protective ground. The socket must be fuse-protected with 10 A(max).
If the unit is installed in a switching cabinet, the mains voltage should be supplied and turned on via a central distributor.
For ground connection, a screw is available on the rear of the unit to connect a ground conductor, for example, with the protective ground of the pump stand.
What are the technical specifications of the INFICON VGC094?
Mains specifications
| Voltage | 100 … 240 V (ac) ±10% |
| Frequency | 50 … 60 Hz |
| Power consumption | ≤65 VA |
| Overvoltage category | II |
| Protection class | 1 |
| Connection | European appliance connector IEC 320 C14 |
| Fuse | integrated in power supply unit (fuse is not accessible) |
Ambience
| Ambient temperature Storage | –20 … +60 °C |
| Ambient temperature Operation | + 5 … +50 °C |
| Relative humidity | ≤80% up to +31 °C, decreasing to 50% at +40 °C |
| Use | indoors only, max. altitude 2000 m |
| Pollution degree | II |
| Degree of protection | IP30 |
Measurement values
| Measurement rate analog | ≥100 / s |
| Display rate | ≥10 / s |
| Measurement filter Limit frequency | OFF, 100 Hz, 10 Hz (default), 1 Hz, 0.1 Hz |
| Measurement unit | hPa, mBar, Torr, Pa, Micron, V, A |
Relay contacts
| Switching function relays | 4 |
| Error relay | 1 |
| Contact type | floating changeover contact |
| Max. load | 60 V (dc), 0.6 A (ohmic) 40 V (ac), 1 A (ohmic) 30 V (dc), 1.5 A (ohmic) 30 V (ac), 1.5 A (ohmic) |
| Service life | Mechanical: 1×10⁸ switching cycles Electrical: 1×10⁵ switching cycles (at max. load) |
| Reaction time | ≤10 ms |
Analog outputs
| Number | 4 |
| Voltage range | 0 … +10 V (dc) ±1% (±0.2% typical) 0 … +5 V (dc) |
| Current range | 4 … 20 mA ±1% (±0.2% typical) |
| Resolution | 16 Bit |
| Output resistance | <50 Ω (typical 47.5 Ω) |
| Response time | ≤10 ms |
Dimensions and Weight
| Dimensions [mm] | 141.9 x 128.5 x ~270 |
| Weight | <1.45 kg |
What are the pin assignments for the interface connectors on the INFICON VGC094?
CONTROL Connector (D-sub, 25-pin female)
| Pin | Signal | Description |
|---|---|---|
| 8, 16, 7 | Switching function 1 | Pin 8: Common, Pin 16: Normally Closed (Pressure above threshold), Pin 7: Normally Open (Pressure below threshold) |
| 5, 13, 4 | Switching function 2 | Pin 5: Common, Pin 13: Normally Closed (Pressure above threshold), Pin 4: Normally Open (Pressure below threshold) |
| 2, 10, 1 | Switching function 3 | Pin 2: Common, Pin 10: Normally Closed (Pressure above threshold), Pin 1: Normally Open (Pressure below threshold) |
| 15, 6, 14 | Switching function 4 | Pin 15: Common, Pin 6: Normally Closed (Pressure above threshold), Pin 14: Normally Open (Pressure below threshold) |
| 12, 3, 11 | Error signal | Pin 12: Common, Pin 3: Normally Closed (Error), Pin 11: Normally Open (No error) |
| 9 | +24 V (dc), 100 mA | Supply for relays |
| 17 | GND | |
| 18 | Analog ground to analog output 1 | |
| 19 | Analog output 1 | |
| 20 | Analog ground to analog output 2 | |
| 21 | Analog output 2 | |
| 22 | Analog ground to analog output 3 | |
| 23 | Analog output 3 | |
| 24 | Analog ground to analog output 4 | |
| 25 | Analog output 4 |
RS485 Connector (Binder M12, 5-pin female)
| Pin | Signal |
|---|---|
| 1 | RS485+ (differential) |
| 2 | +24 V (dc), ≤200 mA |
| 3 | GND |
| 4 | RS485- (differential) |
| 5 | not assigned |
USB Type A Connector (Front panel)
| Pin | Signal |
|---|---|
| 1 | VBUS (5 V) |
| 2 | D- |
| 3 | D+ |
| 4 | GND |
USB Type B Connector (Rear panel)
| Pin | Signal |
|---|---|
| 1 | VBUS (5 V) |
| 2 | D- |
| 3 | D+ |
| 4 | GND |
Ethernet Connector (RJ45, 8-pin)
| Pin | Signal |
|---|---|
| 1 | TD+ (transmission data +) |
| 2 | TD- (transmission data -) |
| 3 | RD+ (received data +) |
| 4 | n.c. |
| 5 | n.c. |
| 6 | RD- (received data -) |
| 7 | n.c. |
| 8 | n.c. |
How do I switch the INFICON VGC094 on and off?
Switching On:
The power switch is on the rear of the unit. Switch on the VGC094 at the power switch. If the unit is incorporated in a rack, switch it on centrally via a switched power distributor. After power on, the VGC094 automatically performs a self-test, activates the parameters that were in effect before the last power off, switches on all measuring circuits with activated hot start and all operational Pirani gauges, and displays the identification of the measuring point.
Switching Off:
Turn the VGC094 off with the power switch (or centrally, if in a rack). Wait at least 10 seconds before turning the VGC094 on again in order for it to correctly initialize itself.
How do I operate the INFICON VGC094 in Measurement Mode?
Measurement mode is the standard operating mode, displaying the measurement value, status messages, and an optional bar graph for each channel.
• Changing measurement channel: Press the left/right arrow keys. The unit alternates between the measurement channels, and the number of the selected channel flashes.
• Switching the gauge on/off manually: Press and hold the up or down key for >1 second. When switching on, a measurement value or status message is displayed. When switching off, the identification of the measuring board is displayed. Note: Switch on cold cathode gauges at pressures <10⁻³ hPa only to prevent excessive contamination.
• Displaying board identification and gauge type: Press the up and down keys together for >0.5 to 1 second. The measurement plug-in board identification (row 1) and the gauge type (row 2) are displayed for 10 seconds.
How do I access and navigate the Parameter Mode on the INFICON VGC094?
The Parameter mode is used for displaying, editing, and entering parameter values.
1. Enter Parameter Mode: From Measurement Mode, press the up and down arrow keys together. The unit switches to parameter mode, and the respective parameter group is displayed.
2. Select a Parameter Group: Use the up and down arrow keys to cycle through the available parameter groups (e.g., SETPOINT, SENSOR, GENERAL). Press the right arrow key to confirm your selection and enter the group.
3. Read a Parameter: Once in a group, use the up and down arrow keys to scroll through the parameters in that group.
4. Edit and Save a Parameter:
a. Navigate to the parameter you wish to edit.
b. Press the right arrow key to confirm. The value flashes, indicating it can be edited.
c. Use the up and down arrow keys to change the value.
d. Press the right arrow key again to save the change and return to the parameter list.
e. To exit the group, navigate to the `<` symbol and press the right arrow key.
How do I configure the Switching Function (Setpoint) parameters on the INFICON VGC094?
In the `SETPOINT` parameter group, you can assign switching functions to channels and set their thresholds. There are four switching functions available.
1. Assign a switching function to a channel:
– Select the `SETPOINT x CH` parameter (where x is 1-4).
– Set the value to `ENABLED` and assign it to a sensor channel (e.g., `SENSOR A1`).
2. Set the lower switching threshold:
– Select the `SETPOINT x LOW` parameter.
– Edit the value. This defines the pressure at which the switching function activates when the pressure is dropping. The range is 1.0E-11 to 9.9E+3 mbar.
3. Set the upper switching threshold:
– Select the `SETPOINT x HIGH` parameter.
– Edit the value. This defines the pressure at which the switching function deactivates when the pressure is rising. The minimum hysteresis between the upper and lower threshold is at least 10% of the lower threshold.
4. Set the ON-Timer:
– Select the `SETPOINT x ON-T` parameter.
– Set a value from 0 to 100 seconds. This delays the switch-off of the relay after the upper threshold has been exceeded.
How do I configure the Gauge (Sensor) parameters on the INFICON VGC094?
In the `SENSOR` parameter group, you can configure settings for the connected gauges.
• Measurement value filter (`FILTER`): Set the filter to OFF, 100 Hz, 10 Hz (default), 1 Hz, or 0.1 Hz to smooth out unstable or disturbed measuring signals.
• Gas type correction (`GAS TYPE`): Calibrate the measurement value to predefined gas types (e.g., Helium, Argon) or select `CORR-FACTOR` for manual input.
• Correction factor (`CORR-FACTOR`): If `GAS TYPE` is set to `CORR-FACTOR`, you can manually enter a correction factor between 0.20 and 8.00.
• Sensor type (`TYPE`): Select the correct sensor type for the recognized plug-in board. This adjusts the measuring characteristic.
• Measuring point name (`DESIGNATION`): Assign a name of up to 8 characters to the measuring point.
• Leakage current compensation (`COMPENSATION`): For cold cathode gauges, you can disable compensation (`OFF`), manually enter a compensation value, or start an automatic measurement to determine and apply a compensation value for leakage currents caused by long cables.
How do I perform a firmware update on the INFICON VGC094?
Firmware update with a USB memory stick (type A)
1. Download two files with the ending “.S19” and “.CNF” to a USB memory stick.
2. Switch off the unit.
3. Plug in the memory stick and then turn on the unit.
4. The update occurs automatically. The display will show messages like `BOOTING`, `ERASING FW…`, `UPDATING FW…`, and finally `UPDATE COMPLETE`.
5. Remove the memory stick, and the unit will restart automatically.
6. If necessary, re-load any customer-specific settings that were saved before the update.
Firmware update with USB Update Tool (USB type B)
Precondition: Windows XP, 7, 8, 10 or 11 operating system. If a virtual serial interface (COM) is not automatically established, you may need to download and install the driver from “ftdichip.com/drivers/vcp-drivers/”.
1. Download the USB UpdateTool software.
2. Connect the unit to the PC using a type A/B USB cable.
3. Start the USB UpdateTool, select the correct COM interface from the menu, and click “Connect”.
4. It is recommended that you first go to the “Manage Parameters” tab and download the current parameters from the device as a backup.
5. Click the “Manage Firmware” tab. You can either load a firmware file from your disk or load it from the update server.
6. Click “Update”. A progress bar will show the update status.
7. If the update was successful, upload your saved parameters back to the device using the “Manage Parameters” tab.
How do I configure the Ethernet connection on the INFICON VGC094?
The INFICON VGC094 can be connected to a network via its Ethernet port, allowing communication through a virtual COM interface or via Winsock/Telnet.
Connecting to a Network (with registration)
1. Read out the MAC address of the VGC094 from the Test Parameters menu.
2. Provide the MAC address to your network administrator to register the device on the network. Obtain the necessary Ethernet parameters (IP ADDRESS, GATEWAY, NETMASK, and DHCP setting) from the administrator.
3. Configure the VGC094 with the provided Ethernet parameters via the front panel in the Communication Parameters menu.
4. Connect the VGC094 to the network with an Ethernet patch cable.
5. Use the Ethernet Configuration Tool on a PC to find the VGC094 on the network and assign it to a virtual COM interface.
6. Start your communication program (e.g., terminal, LabView) and connect it to the assigned COM interface.
Connecting directly to a Computer (without DHCP server)
1. Save all VGC094 parameters to a USB memory stick (“SAVE SETUP”).
2. On a PC, edit the saved CSV file to set the following Ethernet parameters:
• IP ADDRESS: 192.168.0.1 (or similar, ensure it’s on the same subnet as your computer)
• NETMASK: 255.255.0.0
• DHCP: OFF
3. Load the modified parameters back onto the VGC094 (“RESTORE SETUP”).
4. Connect the VGC094 to the computer using a crossover Ethernet cable or a standard patch cable if the interface is auto MDI-X capable.
5. Follow steps 5 and 6 from the network connection guide above.
How do I perform maintenance on the INFICON VGC094?
Cleaning the VGC094
For cleaning the outside of the unit, a slightly moist cloth will usually suffice. Do not use any aggressive or scouring cleaning agents. Ensure no liquids penetrate the equipment, as contact with live parts is extremely hazardous.
Battery replacement
The product contains a battery (type CR2032, service life >10 years) to maintain the data integrity of the real-time clock. Battery replacement is necessary if the real-time clock repeatedly shows an incorrect date. This must be done by an authorized service center.
How do I troubleshoot error messages on the INFICON VGC094?
The error is shown in the dot matrix and the error relay opens. To acknowledge an error, press the right arrow key.
| Error Message | Possible Cause and Remedy/Acknowledgement |
|---|---|
| SENSOR ERROR CHx | Interruption or instability in sensor line or connector (Sensor error). Acknowledge with the key. |
| WATCHDOG ERROR | The VGC094 was turned on too fast after power off, or it has tripped because of a severe electric disturbance or an operating system error. Acknowledge with the key. If the watchdog is set to Auto, the message will be acknowledged automatically after 2 seconds. |
| UART ERROR | Error in UART. Acknowledge with the key. |
| PROGRAM CORRUPT | Program memory error (FLASH). Acknowledge with the key. |
| DATA CORRUPTED | Parameter memory error (EEPROM). Acknowledge with the key. |
| DISPLAY ERROR | Display driver error. Acknowledge with the key. |
| FATAL ERROR | General, serious error. Acknowledge with the key. |
If the problem persists after the message has been acknowledged several times and/or the gauge has been exchanged, please contact your nearest INFICON service center.
How do I use the Data Logger function on the INFICON VGC094?
The data logger group is used for recording measurement data on a USB memory stick (FAT32 formatted, max 32 GB). This group is only available when a suitable USB stick is plugged in.
1. Navigate to the `DATA LOGGER` parameter group.
2. Set the recording mode (`MODUS`):
• `MANUAL`: Start and stop recording using the `START / STOP` parameter.
• `AUTOMATIC`: Recording starts automatically when a USB stick is inserted and stops when it is removed.
3. Set date (`DATE`) and time (`TIME`).
4. Set the recording interval (`INTERVAL`): Can be set to a fixed time (1s, 10s, etc.) or based on a percentage deviation of the measurement value.
5. Set the decimal separator (`DEC-SEPARATOR`): Choose between comma or dot for the data file.
6. Set the file name (`FILENAME`): Enter a name up to 7 characters. The file will be saved with a .CSV extension.
7. Start/Stop Logging (in Manual mode):
• Navigate to the `START / STOP` parameter.
• The display will show ` TO START`. Press the up key to begin recording. The symbol on the screen will blink.
• The display will change to ` TO STOP`. Press the down key to stop recording.
8. Delete data files (`CLEAR`): This option allows you to delete all measurement data files (.CSV) from the USB memory stick.