Free English HYGGER HG137-10W (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD HYGGER HG137-10W (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the features of the HYGGER HG137-10W filter?

The HYGGER HG137-10W filter has the following features:

• Ultra-Quiet Pump: The filter is equipped with a vibration-damping support that reduces vibrations during operation, and the ceramic rotors significantly lower noise further.

• More Oxygen Supply: Two outlets are designed to increase the dissolved oxygen in the water.

• Long Service Life: An all-copper motor water pump extends its service life.

• Adjustable Flow Rate: The flow rate can be adjusted at the water outlet.


What is included in the packing list for the HYGGER HG137-10W?

The packing list for the HYGGER HG137-10W includes:

• 1x Filter

• 1x Water Inlet Pipe

• 1x Filter Basket with Foam

• 4x Filter Cartridge

• 1x User Manual


What are the product specifications for the HYGGER HG137-10W?

Model HG137-10W
Power 10W
Volt/Freq US standard: AC110-120V/60Hz
EU/UK/AU standard: AC220-240V/50Hz
Flow Rate 264GPH (1000L/H)
Size 34.5 x 15 x 18.5 CM (13.6 x 5.9 x 7.3 IN)
Recommended Aquarium Size 30-70Gal

What are the main components of the HYGGER HG137-10W filter?

The main components of the HYGGER HG137-10W filter are:

• Filter cartridge

• Filter body

• Water pump

• Transparent black top cover

• Inlet tube

• Rubber vibration-damping support

• Extension tube 1

• Extension tube 2

• Filter Basket with Foam


How do I install the HYGGER HG137-10W filter?

Follow these steps to install your HYGGER HG137-10W filter:

1. Connect the inlet tube, extension tube(s), and filter basket in turn.

2. Insert the 4-piece cartridge into the filter.

3. Connect the assembled inlet tube to the pump inside the filter.

4. Install the cover on the top of the filter.

5. Important: Before plugging in the filter, fill the pump chamber with approximately 600ml (about 2 cups) of water.


What are the important operational guidelines for the HYGGER HG137-10W?

1. Please fill the pump chamber with around 600ml (about 2 cups) of water before plugging the filter in for the first time.

2. Cleaning the filter sponge weekly is suggested.

3. The temperature range for the filter is 33.8-95°F.

4. Always unplug the filter before maintenance.


What safety precautions should I follow when using the HYGGER HG137-10W filter?

• Before first use, check that the rated voltage and frequency on the filter pump match your operating voltage.

• The power socket should be located above the aquarium’s waterline to prevent water from leaking along the power cord to the socket.

• To ensure safety, the power supply must be unplugged and disconnected when installing, removing, or cleaning the filter.

• The mains plug must not get wet. Never touch the plug with wet hands.

• Personal disassembly of the pump should be avoided.

• Please soak the filter cartridge in water before using it.

• Before use, add water to the filter so that the pump can work properly. It is normal to hear a loud pumping sound when the filter starts; wait about a minute and the noise will disappear.


How do I troubleshoot my HYGGER HG137-10W filter?

Error Cause Solution
The pump does not work No power supply Connect the power supply
The impeller is blocked Clean the impeller and then reconnect the filter to the power supply
The pump is burnt out Contact the seller
Noise during operation The pump is running dry Fill the housing with water and then reconnect the filter to the power supply
The motor’s overheating protection has triggered Clean the impeller, fill the filter housing with water and reconnect the filter to the power supply after waiting 15 minutes
Low water outlet Blockage in the pump chamber or worn axle Remove the impeller cover and remove the blockage; replace the impeller and axle
Dirty filter media Clean or replace the filter media

What are the critical safety warnings for the HYGGER HG137-10W?

• To avoid possible electric shock, do not immerse the pump in water. If the pump falls into the water or becomes wet, do not touch it until you have unplugged it.

• Read and follow the user manual strictly.

• If the pump falls into the water, do not touch it. First unplug it, then pull it out. If electrical parts of the pump get wet, unplug the pump immediately.

• Carefully check the pump after installation. It should not be connected if there is water on parts that are not intended to be wet.

• Do not operate the pump if it has a damaged cord or plug, is faulty, has been dropped or damaged in any way. The power cord is not replaceable. If the cord is damaged, the pump should be discarded.

• Close supervision is required when the pump is used near children.

• To avoid injury, do not contact moving or hot parts.

• Always unplug the pump when it is not in use, before maintenance, or before putting your hands in the water. Never pull the cord to unplug; grasp the plug and pull to disconnect.

• Do not use the pump for any purpose other than its intended use.


How should I set up the power cord for my HYGGER HG137-10W to prevent electric shock?

To avoid the possibility of the pump plug getting wet, position the aquarium and stand to one side of a wall-mounted socket to prevent water from dripping onto it. A “drip loop” should be arranged by the user for each cord connecting the pump to the socket. The “drip loop” is the part of the cord below the level of the outlet or plug that prevents water from traveling along the cord and coming into contact with the outlet. If the plug or socket does get wet, DO NOT unplug the cord. Disconnect power to the outlet at the circuit breaker first, then unplug the power cord and check for water in the outlet. If in doubt, consult a qualified electrician.


Are there specific instructions for using an extension cord with the HYGGER HG137-10W?

If an extension cord is required, use a cord with the correct rating, such as amperes or watts. A cord rated for less amps or watts than the pump rating may overheat. Care should be taken to arrange the cord so that it cannot be tripped over or pulled.


What is the recommended operating environment for the HYGGER HG137-10W?

• Do not install or store the pump where it will be exposed to extreme weather or temperatures below freezing. This pump is suitable for use in temperatures between 32-100°F.

• Make sure the pump is securely installed before operating it.


How should I dispose of the HYGGER HG137-10W?

Do not dispose of this product as unsorted municipal waste. This product must not be disposed of together with domestic waste. It must be disposed of at an authorized place for recycling of electrical and electronic appliances. By collecting and recycling waste, you help save natural resources and ensure the product is disposed of in an environmentally friendly way.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD HYGGER HG137-10W (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.