Free English HYGGER HG137-5W (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD HYGGER HG137-5W (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the key features of the HYGGER HG137-5W hang-on back filter?
Ultra-Quiet Pump: The filter is equipped with a vibration-damping support that reduces vibrations during operation, and the ceramic rotors significantly lower noise further.
More Oxygen Supply: Two outlets are designed to increase the dissolved oxygen in the water.
Long Service Life: All-copper motor water pump extends its service life.
Adjustable Flow Rate: The flow rate can be adjusted at the water outlet.
What is included in the packing list for the HYGGER HG137-5W?
1x Filter
1x Water Inlet Pipe
1x Filter Inlet Pipe (2pcs for 5W)
1x Filter Basket with Foam
2x Filter Cartridge (4pcs for 10W)
1x User Manual
What are the product specifications for the HYGGER HG137-5W?
| Model | HG137-5W | HG137-10W |
| Power | 5W | 10W |
| Volt/Freq | US standard: AC110-120V/60Hz EU/UK/AU standard: AC220-240V/50Hz |
|
| Flow Rate | 132GPH (500L/H) | 264GPH (1000L/H) |
| Size | 16.5 x 13 x 18.5 CM (6.5 x 5.2 x 7.3 IN) |
34.5 x 15 x 18.5 CM (13.6 x 5.9 x 7.3 IN) |
| Recommended Aquarium Size | 10-30Gal | 30-70Gal |
How do I install the HYGGER HG137-5W hang-on back filter?
1. Connect the inlet tube, extension tube and filter tube in turn.
2. Insert the 4-piece cartridge into the filter.
3. Connect the inlet tube to the pump inside the filter.
4. Install the cover on the top of the filter.
5. Important: Fill the water into pump chamber before plugging it in.
What important steps are required before the first use and for regular maintenance of the HYGGER HG137-5W?
1) Please fill the pump chamber with around 600ml (about 2 cups) water before plugging the filter in for the first time.
2) Cleaning the filter sponge weekly is suggested.
3) The temperature range for the filter is 33.8-95°F.
4) Unplug the filter before maintenance.
What are the important attentions and safety precautions for using the HYGGER HG137-5W?
Before using the filter for the first time, please check whether the rated voltage and frequency of the filter pump printed on the filter match your operating voltage.
The power socket should be above the waterline of the aquarium in case the user accidentally disassembles the pump, which could cause water leakage along the power cord to the socket, leading to a leakage accident.
To ensure safety, the power supply must be unplugged and disconnected when installing, removing, and cleaning the filter.
The mains plug must not get wet. For safety reasons, never touch it with wet hands.
Please soak the filter cartridge in water before using it.
Before using the filter, add water to the filter so that the pump can work properly.
When the filter’s pump starts, there may be a loud pumping sound; wait about a minute and the noise will disappear.
How can I troubleshoot problems with my HYGGER HG137-5W?
| Error | Cause | Solution |
|---|---|---|
| The pump does not work | No power supply | Connect the power supply |
| The impeller is blocked | Clean the impeller and then reconnect the filter to the power supply | |
| The pump is burnt out | Contact the seller | |
| The pump is running dry | Fill the housing with water and then reconnect the filter to the power supply | |
| The motor’s overheating protection has triggered | Clean the impeller, fill the filter housing with water and reconnect the filter to the power supply after waiting 15 minutes | |
| Noise during operation | The pump is running dry | Fill the housing with water and then reconnect the filter to the power supply |
| Blockage in the pump chamber or worn axle | Remove the impeller cover and remove the blockage; replace the impeller and axle | |
| Low water outlet | Dirty filter media | Clean or replace the filter media |
What are the critical warnings regarding electrical safety for the HYGGER HG137-5W?
To avoid possible electric shock, do not immerse the pump in the water. If the pump falls into the water or becomes wet, do not touch it until you have unplugged it.
CAUTION: To avoid the risk of electric shock due to water backflow, the pump should be used with a check valve or positioned higher than the water level in the tank.
DANGER: To avoid the possibility of electric shock, special care should be taken when using aquarium equipment since water is involved. Do not attempt to repair the pump yourself.
A. If the pump falls into the water, do not touch it. First unplug it, then pull it out. If electrical parts of the pump get wet, unplug the pump immediately.
B. Check the pump carefully after installation. It should not be connected if there is water on parts that are not intended to be wet.
C. Do not operate the pump if it has a damaged cord or plug, is faulty, has been dropped or damaged in any way. The power cord for this pump is not replaceable. If the cord is damaged, the pump should be discarded.
D. To avoid the possibility of the pump plug getting wet, position the aquarium and stand to one side of a wall mounted socket to prevent water dripping onto the socket or plug. A “drip loop” should be provided by the user for the cord connecting the pump to the socket. The “drip loop” is the part of the cord below the level of the outlet or plug that prevents water from travelling along the cord and coming into contact with the outlet. If the plug or socket does get wet, DO NOT unplug the cord. Remove the fuse from the circuit breaker that supplies power to the pump. Then unplug the power cord and check for water in the outlet. If in doubt, consult a qualified electrician.
What are the guidelines for the proper use and storage environment for the HYGGER HG137-5W?
Do not use the pump for any purpose other than its intended use. The use of attachments not recommended or sold by the manufacturer of the equipment can lead to an unsafe condition.
Do not install or store the pump where it will be exposed to extreme weather or temperatures below freezing. This pump is suitable for use in temperatures between 32-100°F.
Make sure the pump is securely installed before operating it.
Read and observe all the important notices on the pump.
If an extension cord is required, use a cord with the correct rating, such as amperes or watts. A cord rated for less amps or watts than the pump rating may overheat. Care should be taken to arrange the cord so that it cannot be tripped over or pulled.
The pump is intended FOR HOUSEHOLD USE ONLY.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD HYGGER HG137-5W (01) PDF DOCUMENT