Free English HOROW T32 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD HOROW T32 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the electrical requirements for the HOROW T32?
The electrical requirements for the HOROW T32 are 10 Amps at AC 120 V, 60 Hz.
What is the required water pressure range for the HOROW T32?
The minimum water pressure required for the HOROW T32 is 11.6 psi, and the maximum water pressure is 108 psi.
How does the auto flush feature work on the HOROW T32?
The toilet will automatically flush when the user stands up, and the seat sensor no longer detects a user. The auto flush will not be repeated.
How can I perform a blackout flush on the HOROW T32?
Blackout flush refers to the manual emergency flush during a power outage. Press the knob on the toilet to activate the blackout flush.
What is the pre-wet function on the HOROW T32?
When the toilet seat is occupied, the product will flush automatically once towards the seat to moisten the toilet bowl.
How do I adjust the seat temperature on the HOROW T32?
Rotate the knob clockwise to increase the seat temperature. Rotate the knob counterclockwise to decrease the seat temperature. Four adjustable seat temperature levels are provided. Each knob rotation toward the corresponding direction will increase or decrease a temperature level.
How do I use the knob to enter or exit standby mode on the HOROW T32?
When the HOROW T32 is powered on and no one is seated, press and hold the knob for 3 seconds to enter the standby mode. When the toilet is in standby mode, press and hold the knob for 3 seconds to activate it.
How can I toggle the night light on the HOROW T32?
When the seat is occupied, press and hold the knob and rotate it clockwise to turn the night light on or off.
How do I enable or disable the auto flush function on the HOROW T32?
When the seat is occupied, press and hold the knob for 3 seconds to enable or disable the auto flush function.
How do I enable or disable the buzzer on the HOROW T32?
When the seat is unoccupied, press and hold the knob and rotate it clockwise to enable or disable the buzzer.
How do I enable or disable the pre-wet function on the HOROW T32?
When the seat is occupied, press and hold the knob and rotate it counterclockwise to enable or disable the pre-wet function.
How do I enable or disable the energy-saving mode on the HOROW T32?
When the seat is unoccupied, press and hold the knob and rotate it counterclockwise to enable or disable the energy-saving mode.
What is the function table for the HOROW T32?
| Category | Functions | T32 |
|---|---|---|
| Hygiene | Anti-bacterial Seat | ● |
| Hygiene | Easy-clean Glaze | ● |
| Hygiene | Pre-wet | ● |
| Comfort | Heated Seat | ● |
| Comfort | Adjustable Seat Temperature | ● |
| Convenience | Auto Flush | ● |
| Convenience | Blackout Flush | ● |
| Convenience | Night Light | ● |
| Convenience | Energy-saving Mode | ● |
| Convenience | Soft Close | ● |
| Convenience | Factory Data Reset | ● |
| Safety | Air Isolation & Backflow Prevention | ● |
| Safety | Multiple Protections | ● |
| Safety | Fire and Heat Resistant | ● |
How should I maintain the ceramics, seat, and lid of the HOROW T32?
1. Wipe dust or stains with a soft wet cloth.
2. A wet soft brush, cloth, or sponge may be used to clean the ceramic area.
Do not use abrasive cleaners, such as alcohol, bleach, painter thinner, cresol, benzene, gasoline, etc.
What precautions should be taken for the HOROW T32 during the winter season?
During the winter season, the water inside may freeze after long periods of storage and non-use. Before connecting the product to the water supply and electrical outlet, allow it to defrost for 30 minutes in a warm indoor environment. In cases of extreme cold or freezing in place, wrap the water input line with a warm towel. Never pour hot water or use a hot dryer directly on the toilet.
What should I do if the HOROW T32 is not working?
Troubleshooting steps include:
Check whether the attaching plug is loose or not: Please check the circuit.
Check whether the power is switching on or off: Press and hold the knob, the power light is on.
Check whether there is any electric leakage or not: Unplug the attaching plug from the socket, plug it again later, if it is still not working, please unplug the attaching plug and contact Customer Service.
What should I do if the seat temperature of my HOROW T32 is too low?
Check whether the temperature of the toilet seat is on the OFF position or not. Regulate the temperature of the toilet seat according to the manual.
What should I do if my HOROW T32 does not flush cleanly?
If there is no power supply, check for power restoration.
If there is no water from the spout, please contact Customer Service.
If there is no water but you hear the sound of flushing, check whether the pipeline is blended or not, and keep the water supply pipeline open and smooth.
If there is water running all the time, please contact Customer Service if there is anything unusual with the water inlet valve.
CLICK HERE TO DOWNLOAD HOROW T32 (01) PDF DOCUMENT