What is the intended operating temperature for the HARMONY HMO6353R?
The HARMONY HMO6353R self-service case is designed to merchandise packaged products at 41 °F (5 °C) or less product temperatures, unless equipped with custom wire rack shelving.
What ambient store conditions are required for Type 1 vs. Type 2 operation of the HARMONY HMO6353R?
For Type 1 conditions, ambient store conditions must be maintained at a maximum of 55% humidity and maximum temperatures of 75 °F (24 °C).
For Type 2 conditions, ambient conditions must be maintained at a maximum of 60% humidity and maximum temperatures of 80 °F (27 °C).
To determine if the case is designed for Type 1 or Type 2, check the tag located next to the serial label.
What electrical and plumbing compliance standards must be followed when installing the HARMONY HMO6353R?
The equipment must be installed in full compliance with all applicable National Electrical Code (NEC), federal, state, and local electrical and plumbing codes. Performance issues resulting from code violations are not covered.
What electrical safety warnings must be observed prior to servicing the HARMONY HMO6353R?
Risk of electric shock: Disconnect power before servicing the unit.
More than one source of electrical supply is employed with units that have separate circuits. Disconnect all electrical sources before servicing.
What moving parts hazard exists when operating the HARMONY HMO6353R?
Hazardous moving parts: Do not operate the unit with covers removed. Fan blades may be exposed when the deck panel is removed. Disconnect power before removing the deck panel.
What warning applies to the electric coil condensate pans on the HARMONY HMO6353R?
Electric coil condensate pans are hot. Disconnect and allow to cool before cleaning or removing from the case.
What circuit breaker type is recommended for the HARMONY HMO6353R?
If the National Electric Code (N.E.C.) or local codes require Ground Fault Circuit Interrupter (GFCI) protection, the use of a GFCI breaker is strongly recommended.
What spacing and environmental conditions must be maintained around the HARMONY HMO6353R?
The unit must be kept at least 15 feet from exterior doors, overhead HVAC vents, or any air curtain disruption to maintain proper temperatures.
The unit must not be exposed to direct sunlight or any heat source, such as ovens or fryers.
Keep at least an 8-inch clearance above the unit for air discharge on self-contained units.
What lamp replacement guidelines must be followed for the HARMONY HMO6353R?
LED lamps reflect specific size, shape, and overall design. Any replacements must meet factory specifications.
Fluorescent lamps have been treated to resist breakage and must be replaced with similarly treated lamps.
What checks are necessary for the condensate pan and plug before powering up the HARMONY HMO6353R?
Water on flooring can cause extensive damage. Before powering up the unit, verify the following:
The condensate pan must be positioned directly under the condensate drain.
The condensate pan plug must be securely plugged into the receptacle.
Check that the overflow pan is fully functional.
If wicking material is used, check that it is secure.
What maintenance is required for damaged power cords or plugs on the HARMONY HMO6353R?
To avoid the risk of electric shock, if a cord or plug becomes damaged, replace it only with a cord and plug of the same type.
Where can the wiring diagram be found on the HARMONY HMO6353R?
Each case has its own wiring diagram folded inside its own packet. Placement may vary, but it may typically be placed near the ballast box, field wiring box, raceway cover, or other related electrical location.
How should the HARMONY HMO6353R be inspected during shipment and unloading?
Check all equipment for damage before and during unloading.
If using a third-party carrier and damage is discovered, describe the damage on the freight bill and obtain the signature of the driver, who will supply claim forms.
For prepaid and add shipments, contact the carrier and notify technical service.
Where should the uncrating of the HARMONY HMO6353R take place?
Uncrating equipment at a facility other than the installation site may result in severe damage to the unit when transporting it to its final destination. It is strongly recommended that the equipment only be uncrated at the installation site.
How do you remove the case shipping brackets from the skid on the HARMONY HMO6353R?
Step 1. Remove the screws holding the case shipping brackets to the skid.
Step 2. Remove the case shipping brackets from the skid.
How do you remove the HARMONY HMO6353R equipped with levelers from its skid?
Step 1. To prevent damage, support the case while sliding it toward the edge of the skid.
Step 2. When the case is at the edge of the skid, carefully lower it to the floor so that two levelers rest on the floor.
Step 3. Carefully slide the skid out from under the case.
Step 4. After removal from the skid, place the case into position.
How do you remove the HARMONY HMO6353R equipped with casters from its skid?
Step 1. Place a ramp up against the skid to allow the case to smoothly slide off.
Step 2. Maintain support of the case at all times; otherwise, the center of gravity may cause the case to fall.
Step 3. Unlock the casters.
Step 4. Slide the unit to the rear of the skid, down the ramp, and off from the skid.
What airflow clearance must be maintained for self-contained HARMONY HMO6353R units?
Self-contained refrigerated cases must maintain an airflow clearance of 6 inches minimum to 12 inches recommended at the front and rear. Restriction of air can void the warranty.
What is the step-by-step procedure for caulking and bolting HARMONY HMO6353R units together in a lineup?
Step 1. Begin all lineups by leveling from the highest point of the floor.
Step 2. After the first case is level, apply industrial grade butyl caulk on non-visible areas at the case end, and use industrial grade silicone sealant on visible areas at the case end.
Step 3. Form two caulk/sealant lines: one sanitation bead and one refrigeration bead.
Step 4. Line up the second case bolt-hole to bolt-hole with the first case.
Step 5. Using the supplied bolts, insert bolts in the bolt hole locations (decking may need to be removed to access lower bolt holes).
Step 6. Verify that the fronts of the cases are flush with each other and that all cases are leveled to the same height.
Step 7. Using supplied nuts and bolts, lightly tighten each of the 5 to 8 bolts in a cross-wise pattern. Work around the pattern, tightening more firmly at each pass. Do not firmly tighten one bolt and then start on the next.
Step 8. After the cases are bolted together, level the second case. Repeat this process for each case to be adjoined.
Step 9. After all lined-up cases are level, seal all seams with industrial grade silicone sealant.
How are the levelers adjusted on the HARMONY HMO6353R?
Step 1. Ensure the case is in its proper position and aligned with any adjoining cases before adjusting.
Step 2. If necessary, remove the front and/or rear toe-kick to access the levelers.
Step 3. Use an adjustable wrench to adjust the leveler until the unit is level and plumb.
Step 4. If using a pry bar to raise a heavy case, use the pry bar only on the base frame. Never use a pry bar on the toe-kick (which may buckle) or the end panel (which may chip).
How must frame support rails be leveled and sealed on the HARMONY HMO6353R?
Shims are provided with cases that have frame support rails. Use the shims underneath the rails to level the case. Once the case is in position and level, it must be sealed to the floor to prevent entry or leakage of liquid or moisture.
How do you remove the front grille on the HARMONY HMO6353R when secured with screws?
Step 1. Remove the front grille horizontal retainer screws located at each end of the case.
Step 2. Remove the front grille vertical retainer screws along the entire underside of the front panel.
Step 3. Allow the front grille to fall forward, then lift it up and away from the case.
Step 4. To reinstall, reverse the removal order and tighten all retainer screws securely.
How do you remove the front grille on the HARMONY HMO6353R when equipped with retaining hooks?
If the front grille is held in place with retaining hooks, simply lift the front grille straight up and off the case. No screws are required for removal or installation.
How is the optional magnetized condenser coil filter serviced on the HARMONY HMO6353R?
The removable magnetized condenser coil filter is positioned on the outside of the rear grille and is held in place with magnetic strips. It can be pulled off directly for cleaning or service.
How do you remove the rear grille and rear panel on the HARMONY HMO6353R?
To remove the rear grille: Lift the grille slots up and off the rear panel retainer hooks.
To remove the rear panel: Unscrew the four Phillips screws (do not use a flat-head screwdriver) holding the panel in place, then remove the panel.
How are the compressor pan shipment screws removed on the HARMONY HMO6353R?
At initial access to the refrigeration package, locate the compressor pan shipment screw at each end. Due to the location, use a Phillips screwdriver with an extension to remove the screws.
How do you start up the HARMONY HMO6353R?
For remote units: The case is hard-wired. When electrical power is supplied, the case powers up automatically.
For self-contained units: Turn on the main power switch located at the lower right rear of the case. The temperature controller is located at the lower left rear.
To operate lights: Turn on the light switch located on the inside of the case at the top right (viewed from the rear). All lights should illuminate simultaneously.
Why do all lighting receptacles need to be plugged in or capped on the HARMONY HMO6353R?
The lighting circuit is wired in series. Therefore, all lights must be plugged in or the open receptacles must be capped for the case lights to turn on.
How is the optional night air curtain operated on the HARMONY HMO6353R?
Step 1. Handle the night air curtain with care.
Step 2. Grasp the handle and pull downward to the desired area outside the acrylic sneeze guard (or upward depending on configuration).
Step 3. Attach the magnets on the extended curtain to the metal plate/support to hold it firmly in place.
Step 4. To retract, grasp the handle, lift the curtain straight up and away from its magnetic attachment, and carefully guide the curtain back into the roll.
Step 5. Do not allow the spring-loaded night air curtain to freely snap back into the roll, as this can destroy its tension and retractability.
Step 6. Do not drag or slide the curtain across metal surfaces when extending or attaching to avoid scratching.
How do you install the optional security grid on the HARMONY HMO6353R?
Step 1. Security grid installation requires two people due to its size and weight.
Step 2. Hoist the security grid directly over the front air deflector.
Step 3. Drop the two security grid positioning tabs into the baffle airflow slots at each end.
Step 4. Slowly and carefully lean the security grid back against the two security brackets.
Step 5. Slide the padlocks through the security grid and security brackets, then lock them securely.
How do you remove the shelf assemblies on the HARMONY HMO6353R?
Step 1. Remove the glass shelves.
Step 2. For lighted shelves, unplug the light cord from its receptacle.
Step 3. Lift the light shelf upward to separate it from the brackets.
Step 4. Remove the rear shelf support.
Step 5. Remove the shelf brackets. If nylon shipping bracket retainers are present, pliers will be required to remove them.
How are fluorescent lamps removed and replaced in the HARMONY HMO6353R?
Lamp removal: Rotate the lamp 1/4-turn in either direction to disengage the pinned contacts from the mounting sockets. Apply even pressure from the back side at the bulb ends and pull the contacts from the sockets.
Lamp installation: Align the pins with the socket slot. Insert the pins into the socket and rotate the bulb 1/4 turn to secure the contacts into the sockets. Rotate the remaining bulb contacts 1/4 turn into the opposing socket contacts.
How are LED light fixtures removed and replaced on the HARMONY HMO6353R?
Step 1. Disconnect the existing LED light from its mounting brackets and self-adhesive tape.
Step 2. Firmly grasp the LED light while applying outward pressure to the brackets.
Step 3. Twist the LED fixture out and away from the bracket to release it.
Step 4. When connecting the replacement, verify the plug connects at the raceway side without doubling back the cord.
Step 5. Ensure the oval form of the plug aligns properly with the oval form of the LED fixture, or the light will not illuminate.
What is the daily cleaning procedure for the acrylic sneeze guard on the HARMONY HMO6353R?
Clean the acrylic sneeze guard daily with a mild soap and water solution and a soft cloth.
Never use ammonia-based cleaners, abrasive cleaners, or abrasive cloths on acrylic, as incorrect cleaning agents cause surfaces to cloud over time.
How should exterior and interior glass surfaces be cleaned on the HARMONY HMO6353R?
Clean the side glass, front curved glass, rear glass, and glass shelves daily using a standard household or commercial glass cleaner and a soft cloth.
What is the cleaning method for wood, laminate, and painted surfaces on the HARMONY HMO6353R?
Clean wood, laminate, and painted surfaces daily using a warm soap and water solution and a soft cloth. Never use wire cloths or abrasive cleaning agents on the case.
How should the optional magnetic rear air filter be cleaned on the HARMONY HMO6353R?
Depending on the operating environment, clean the air filter weekly or at least monthly.
Step 1. Remove the magnetic filter from the rear grille.
Step 2. Submerse the filter in warm, soapy water.
Step 3. Use a soft-bristled brush to gently remove collected dust, grease, and grime.
Step 4. Rinse thoroughly with clean water.
Step 5. Allow the filter to dry completely before returning it to the case.
How should interior shelves, decks, and risers be cleaned on the HARMONY HMO6353R?
Clean shelves, decks, and risers daily with a warm soap and water solution.
For stubborn stains or residue, decks and risers can be removed and cleaned with soapy water or submersed in a hot, soapy water solution. Rinse thoroughly, dry, and return them to the case.
Who is permitted to remove the lower interior decking on the HARMONY HMO6353R?
Decking is not to be removed by store personnel during routine cleaning. Removal of decking exposes moving fan parts and must only be performed by trained service providers with the power disconnected.
What is the general stainless steel cleaning schedule and procedure for the HARMONY HMO6353R?
Step 1. Wash surfaces with a solution of liquid dishwashing detergent and hot water.
Step 2. Rinse thoroughly with pure hot water from a spray bottle and wipe with a clean sponge to remove soap residue from microscopic grooves.
Step 3. Dry completely with a clean, soft cloth or paper towel.
Caution: Never clean with scouring powder or steel wool as they scratch and erode the protective surface, which will cause rust to form.
What methods can be used to brighten stainless steel surfaces on the HARMONY HMO6353R?
Method 1: Polish with a soft cloth or sponge using a solution of 1 part vinegar to 2 parts water mixed in a spray bottle.
Method 2: Sprinkle baking soda onto a sponge and rub gently using a soft cloth or sponge.
Always rinse thoroughly with pure hot water from a spray bottle and wipe with a clean sponge after cleaning, then dry with a soft cloth.
How can streaks or stains be removed from the stainless steel on the HARMONY HMO6353R?
Method 1: Place two teaspoons of rubbing alcohol on a microfiber cloth or pad. Rub along the grain of the metal until the entire area is covered; allow it to air dry.
Method 2: Dip a soft cloth or sponge into club soda and rub gently over the affected area. Rinse with pure hot water from a spray bottle, wipe with a clean sponge, and dry.
How should stainless steel surfaces be polished on the HARMONY HMO6353R?
Step 1. Apply a dab of olive oil onto a clean soft cloth and spread it over the metal until a light sheen appears.
Step 2. Use firm, steady pressure using small circular motions to work the oil into the small surface grooves.
Step 3. Dry buff using a clean cloth or paper towel in small circular motions to remove excess oil.
Step 4. Wet buff using an ounce of white vinegar on a clean cloth or paper towel until the oily finish is fully removed.
Step 5. Rinse with hot water from a spray bottle, wipe with a clean sponge, and dry with a soft cloth.
How is rust treated and removed from the stainless steel on the HARMONY HMO6353R?
If rust forms, treat it using specialized cleaning products such as CLR (calcium, lime, and rust remover) or Chemetall Oakite 33 (rust, oxide, and scale remover). Follow all manufacturer safety instructions, dilutions, and precautions to prevent food contamination or further corrosion.
What is the store-level cleaning frequency table for the HARMONY HMO6353R?
| Area to Clean | Frequency | Instructions |
|---|---|---|
| Case Exterior: Acrylic | Daily | Clean sneeze guard with mild soap and water solution and soft cloth. Never use ammonia. |
| Case Exterior: Glass | Daily | Clean side, front curved, and rear glass with glass cleaner and soft cloth. |
| Case Exterior: Wood/Laminate/Paint | Daily | Clean with warm soap and water solution and soft cloth. No abrasive cleaners. |
| Case Exterior: Stainless Steel | Daily | Wash with dish detergent and hot water, rinse with hot water spray, dry with soft cloth. |
| Case Exterior: Air Filter on Rear Grille | Weekly to Monthly | Submerse in warm soapy water, scrub with soft brush, rinse thoroughly, dry before reinstalling. |
| Case Interior: Shelves/Decks/Risers | Daily | Clean with warm soap and water solution. Rinse thoroughly and dry. |
| Case Interior: Shelf Supports/Air Return Grilles | Weekly | Wipe down with moist cloth. Grilles and supports may be removed for thorough cleaning. |
| Case Interior: Condenser Coil | Monthly | Vacuum or brush coil at front with metal or fiber brush. Do not damage fins. |
What should store personnel do if water is found on the floor around the HARMONY HMO6353R?
Immediately call an authorized service provider. Store personnel should extract standing water using a wet-dry vacuum or mop and use catch pans until service arrives to prevent floor damage.
What should store personnel check if the lights on the HARMONY HMO6353R are not working?
Step 1. Check that the light switch is in the “ON” position.
Step 2. Verify that all light cords and plugs are properly connected and seated, or that open receptacles are capped.
Step 3. If the lights still do not illuminate, call a trained service provider.
What should store personnel check if the HARMONY HMO6353R is not holding proper temperature?
Step 1. Check if warm product was recently loaded; products must be pre-chilled before loading into the case.
Step 2. Check that the case is not positioned in direct sunlight or directly in front of heating or air conditioning vents.
Step 3. Check that the air filter and condenser coil are clean.
Step 4. Inspect the air return grilles at the front of the decking for blockages. Do not place products over the grilles.
Step 5. If the case still does not maintain temperature, contact a trained service provider.
How should a service technician clean the evaporator fan shroud and tub area on the HARMONY HMO6353R?
Turn off the case power and disconnect the plug from the wall outlet prior to cleaning due to rotating fan hazard.
Monthly: Remove the display decks, and wipe down the fan shroud area and surrounding tub with a moist cloth.
Quarterly: Vacuum the tub beneath the deck boards, clean with a mild soap and water solution, wipe dry with a clean cloth, and verify the drain is free of debris to prevent clogs.
How is the wicking material inspected and maintained on the HARMONY HMO6353R?
Perform a quarterly check on units equipped with hot gas condensate pans. Disconnect power, slide the refrigeration assembly out from under the unit, and inspect the wicking material. If it is tattered, worn, dirty, or disintegrating, replace it with new wicking material.
What causes water on the floor under the HARMONY HMO6353R from a technician’s troubleshooting perspective?
Drain trap obstructed with debris.
Drain hose incorrectly positioned over the evaporator pan or floor drain.
Ambient store conditions exceeding allowable limits (greater than 55% humidity / 75 °F for Type 1, or greater than 60% humidity / 80 °F for Type 2).
Evaporator pan float not operating properly (heat rod evaporator systems).
Evaporator pan unplugged, disconnected, or malfunctioning.
Power disruption causing condensation overflow.
Wicking material dirty, worn, or decomposing on hot gas evaporator pans.
What should be checked if a fan emits excessive noise on the HARMONY HMO6353R?
Check that the case is aligned, level, and plumb.
Check the evaporator fan for cleanliness.
Power off the fan motor and inspect the motor shaft for bearing wear.
Verify that the fan motors are firmly mounted in their brackets.
Verify that the fan blades are securely attached to the motor shaft.
Check that no foreign objects or wires are obstructing blade rotation.
Verify that the fan shroud is firmly secured.
What troubleshooting steps apply if the fans are not operating on the HARMONY HMO6353R?
Check that the main power switch is in the “ON” position.
Verify that the fans are securely plugged in at the fan shroud harness.
Check for physical obstructions preventing blade rotation.
Confirm that the fan blades rotate freely by hand.
Check electrical voltage and verify power is reaching the fans.
Verify that fan wiring leads are properly secured to the terminal blocks.
What should be checked if the digital control display is blank on the HARMONY HMO6353R?
Check that the main power switch is turned on.
Inspect the main electrical panel/circuit breaker box for tripped breakers or blown fuses.
What causes the temperature controller display to flash on the HARMONY HMO6353R?
A flashing display indicates an active alarm or altered operational parameter. Refer to the serial label on the case for the correct factory settings, and consult the controller alarm tables to determine the cause.
What refrigeration issues can cause the HARMONY HMO6353R to not hold temperature?
Case is in active defrost mode (the fourth LED indicates defrost; temperatures temporarily rise but will normalize).
Condenser coil or magnetic filter is dirty and restricted.
Air return grilles are blocked by merchandise.
Refrigerant charge is low, or bubbles/flashing are visible in the sight glass.
The setpoint temperature is set too high.
Adverse store conditions exist, such as high ambient temperature, drafts from doors, or HVAC vents.
What should be checked if the condensing unit on the HARMONY HMO6353R is not operating?
Verify that the main electrical utility power is on and the main case switch is on.
Verify that the temperature controller parameters and setpoints match the factory settings specified on the serial label.
What causes excessive high head pressure on the HARMONY HMO6353R?
Dirty, clogged, or covered condenser coil.
Condensing fans inoperative.
Overcharged refrigerant system.
Non-condensables present in the refrigeration circuit.
Plugged or restricted liquid line drier.
Air recirculation caused by close-offs missing or blocked around the condenser coil.
Temperature setpoint adjusted too high.
Store ambient temperature exceeds allowable operating limits.
What causes low head pressure on the HARMONY HMO6353R?
Refrigerant charge is too low.
Suction pressure is running too low.
Defective or worn compressor valves.
What causes low suction pressure on the HARMONY HMO6353R?
Low refrigerant charge.
Restricted thermal expansion valve (TXV).
Restricted liquid line or liquid line filter drier.
Failed or non-functioning evaporator fan motors.
High superheat requiring adjustment.
Depleted thermostatic element charge on the expansion valve.
Air seepage around the coil or an iced-up evaporator coil.
What causes high suction pressure on the HARMONY HMO6353R?
Excessive refrigerant charge.
Damaged or leaking compressor valves.
Excessive cooling load on the case.
Superheat setting adjusted too low.
Improper TXV bulb installation (poor thermal contact or mounted in an overly warm location).
Undersized compressor capacity.
What is the quarterly preventive maintenance procedure for the condenser coil on the HARMONY HMO6353R?
Step 1. Turn off power to the unit.
Step 2. Remove the access panel by lifting up and off or removing screws.
Step 3. Use compressed air or an industrial vacuum to clean dust and dirt from the condenser coil fins.
Caution: Coil fins are sharp; handle with care. If using compressed air, place wet rags over the opposite side to prevent airborne dust from contaminating food products.
Step 4. Reinstall the access panel.
What preventive maintenance is required quarterly for the refrigeration package and compressor area on the HARMONY HMO6353R?
Step 1. Disconnect power from the case. Ensure the evaporator pan has cooled before touching it.
Step 2. Carefully slide or roll the compressor package out from underneath the case.
Step 3. Clean the evaporator pan using a scrub brush and a de-scaling solution such as CLR to remove lime, rust, and scale.
Step 4. Rinse the pan thoroughly with clean water from a spray bottle and dry with a clean sponge or paper towel.
Step 5. Use a moist cloth to wipe away accumulated dust and debris from fans, sight glass, overflow pans, and tubing.
Step 6. Vacuum the floor under the case while the assembly is removed.
Step 7. Carefully slide the refrigeration package back into position and secure the panels.
How do you remove, clean, and reinstall the honeycomb air diffuser on the HARMONY HMO6353R?
Removal: Wedge a non-metallic device of suitable strength (such as a ballpoint pen) between the honeycomb diffuser and the end panel. Use caution not to dislodge the heating wire that prevents condensation. Apply gentle pressure to collapse the honeycomb structure slightly and pull it down and out of the retainer.
Cleaning: Wash the honeycomb in warm water and mild soap solution. Submerse if necessary, using a soft brush to remove stubborn dirt. Dry by setting a vacuum to blow mode (do not use suction mode).
Installation: Squeeze the honeycomb to fit it back into the retainer, slide it into place, and adjust it so it sits completely flat without waves or distortion.
How do you modify the temperature setpoint on the Carel controller of the HARMONY HMO6353R?
Step 1. Press and hold the “SET” key for at least 1 second until the setpoint value displays.
Step 2. Use the Up (aux) or Down (def) arrow buttons to adjust the setpoint value to the desired temperature.
Step 3. Quickly press and release the “SET” key again to confirm and save the setting.
How do you modify parameters such as defrost and differential on the Carel controller of the HARMONY HMO6353R?
Step 1. Press and hold the “Prg/mute” and “SET” keys together for 5 seconds until the display flashes “0” (password prompt).
Step 2. Press the “SET” key to confirm.
Step 3. Press the Up (aux) or Down (def) arrow keys to navigate to the parameter code you wish to modify.
Step 4. Press the “SET” key to display the current parameter value.
Step 5. Use the Up or Down arrow keys to increase or decrease the value.
Step 6. Press “SET” temporarily to store the value and return to parameter code display.
Step 7. Press and hold the “Prg/mute” key for at least 5 seconds to permanently save changes. If no button is pressed within 60 seconds, the controller will time out and discard changes.
How do you switch the temperature readout between Fahrenheit and Celsius on the Carel controller of the HARMONY HMO6353R?
Step 1. Press and hold the “Prg/mute” and “SET” keys together for at least 5 seconds until “0” appears.
Step 2. Press “SET” to confirm.
Step 3. Press the Up or Down arrow key until reaching parameter “/5”.
Step 4. Press “SET” to access the parameter.
Step 5. Press the Up or Down arrow key to select “0” for Celsius (°C) or “1” for Fahrenheit (°F).
Step 6. Press “SET” to temporarily save the new value.
Step 7. Press and hold “Prg/mute” for at least 5 seconds to permanently store the change. All values will automatically convert to the new scale.
How is a manual defrost initiated on the Carel controller of the HARMONY HMO6353R?
Press and hold the Down arrow / Defrost (“def”) key for at least 5 seconds to trigger a manual defrost cycle.
How are manual reset alarms reset on the Carel controller of the HARMONY HMO6353R?
Press and hold the “Prg/mute” and “aux” keys simultaneously for at least 1 second to clear and reset manual reset alarms.
What are the common Carel controller operating parameters and their allowable ranges for the HARMONY HMO6353R?
| Code | Parameter | Unit | Type | Min | Max |
|---|---|---|---|---|---|
| /5 | Select Celsius (°C) or Fahrenheit (°F) | flag | C | 0 | 1 |
| /c1 | Calibration of probe 1 | °C/°F | C | -20 | 20 |
| /c2 | Calibration of probe 2 | °C/°F | C | -20 | 20 |
| St | Temperature set point | °C/°F | F | r2 | r1 |
| rd | Control delta | °C/°F | F | 0.1 | 20 |
| dl | Interval between defrosts | hours | F | 0 | 250 |
| dt1 | End defrost temperature, evaporator | °C/°F | F | -50 | 200 |
| dP1 | Maximum defrost duration, evaporator | min | F | 1 | 250 |
| d6 | Display on hold during defrost | – | C | 0 | 2 |
| dd | Dripping time after defrost | min | F | 0 | 15 |
| d/1 | Display of defrost probe 1 | °C/°F | F | – | – |