| Supply voltage | 230V AC ±10% 50 Hz |
| Power consumption | 2W |
| Output relay SPST | 20A |
| Ambient temperature | -5°/+50°C during operation |
| On/off differential | 0.5°/10° |
| Housing | IP 20 |
| Material | Non-flammable PC |
What are the main operating modes and functions of the GRAND MEYER HW500I?
The GRAND MEYER HW500I thermostat has two main operating modes:
Manual Mode: In this mode, you can set and maintain a constant temperature manually.
Programmable Mode: In this mode, you can use an adjustable program to maintain different temperatures automatically throughout the day and week.
The thermostat also features the following functions, represented by symbols:
• Wake-up
• Return (am)
• Return (pm)
• Heating On
• Frost protection
• Leave (am)
• Leave (pm)
• Sleep
• Key Lock
How do I set the clock and day of the week on the GRAND MEYER HW500I?
To set the clock on your GRAND MEYER HW500I, press the Menu (M) and Up (▲) buttons and hold for 5 seconds until the digit flashes. Use the Up (▲) or Down (▼) buttons to set the clock. Then, set the day of the week (1 for Monday, 2 for Tuesday, etc.). Press the Menu (M) key to confirm the entry.
How do I switch between manual and programmable modes on the GRAND MEYER HW500I?
To switch between modes on the GRAND MEYER HW500I, press the Menu (M) key. The display will show a hand symbol for manual mode or a clock symbol for programming mode.
How do I use the manual mode on the GRAND MEYER HW500I?
When the manual mode symbol (hand) is shown on the display, you can set the desired temperature using the Up (▲) or Down (▼) buttons. The desired temperature and time will be shown on the left side of the display, and the actual temperature will be shown on the right side of the display.
How do I set up the programmable mode on the GRAND MEYER HW500I?
To set up the programmable mode on your GRAND MEYER HW500I, hold down the Menu (M) key for 5 seconds. The display will show events according to the schedule. The first five days of the week have 6 events, while the weekends have two events (Wake-Up and Sleep). For each event, you can set up the operating time and desired temperature. Use the Up (▲) or Down (▼) keys to set the time and/or temperature. Use the Menu (M) key to move to the next event. The desired temperature and time are shown on the left, and the actual temperature is on the right.
The recommended temperature for underfloor heating is 25-27°C.
What is the default schedule for the programmable mode on the GRAND MEYER HW500I?
| Day of the week | Event (symbol) | Time | Temperature |
|---|---|---|---|
| 1 – 5 (Mon-Fri) | 1 (Wake-up) | 06:00 | 20°C |
| 2 (Leave am) | 08:00 | 15°C | |
| 3 (Return am) | 11:30 | 15°C | |
| 4 (Leave pm) | 12:30 | 15°C | |
| 5 (Return pm) | 17:00 | 22°C | |
| 6 (Sleep) | 22:00 | 15°C | |
| 6, 7 (Sat-Sun) | 1 (Wake-up) | 06:00 | 20°C |
| 2 (Sleep) | 22:00 | 15°C |
What do the different symbols and numbers on the GRAND MEYER HW500I display mean?
1) Programmable mode periods: Shows the current event number in programmable mode.
2) Clock and desired temperature: Shows the current time and the set temperature.
3) Day of the week: Numbers 1-7 representing Monday to Sunday.
4) Increase/Decrease key: Buttons to adjust settings.
5) Menu: Button to switch modes and confirm settings.
6) Manual mode: Symbol (hand) indicates manual mode is active.
7) Programmable mode: Symbol (clock) indicates programmable mode is active.
8) Frost protection: Symbol (snowflake) indicates frost protection is active.
9) Sleep: Symbol (moon) indicates a sleep period is active.
10) Actual temperature: Shows the current room temperature.
11) Key lock: Symbol (lock) indicates the keys are locked.
12) Heating on: Symbol (radiator) indicates the heating is currently active.
13) ON/OFF key: The power button.
14) Internal temperature sensor: Indicates the internal sensor is in use.
How do I access and change the advanced settings on the GRAND MEYER HW500I?
To access the advanced setting menu on your GRAND MEYER HW500I, press the Power and Menu (M) buttons at the same time. You can then use the Up (▲) or Down (▼) buttons to change the values for each setting. The table below details the available settings.
| Symbol | Settings | Options |
|---|---|---|
| 1AdJ | Temperature calibration | Set the temperature range |
| 2SEN | Active temperature sensor | IN: only internal build-in sensor OU: only external sensor ALL: both sensors |
| 3L. F | External sensor upper temperature limit | From +5°C to +60°C |
| 4d. F | Temperature hysteresis | From 0,5° to 10° |
| 5LFF | Frost protection | ON: ON OFF: OFF |
| 6P-G | Weekly programming | 5 working/2 weekend days 6 working/1 weekend days 7 working days |
| 7rLE | Relay contacts | 00: NO 02: NC 01: NO 03: NC |
| 8dLY | Not used on this model | – |
| 9H. F | Temperature upper limit | From +5°C to +60°C |
| AFAC | Reset to factory settings | Press Menu (M) key for 5 seconds till showing — |
How do I activate or deactivate the key lock function on the GRAND MEYER HW500I?
To activate or deactivate the key lock function on the GRAND MEYER HW500I, press both the Up (▲) and Down (▼) buttons for 5 seconds. The lock symbol will appear on the display when the function is switched on.
What are the installation steps for the GRAND MEYER HW500I?
Please follow these steps to install the GRAND MEYER HW500I thermostat. WARNING: Disconnect the power supply before carrying out any installation work.
1. Remove the outer frame of the thermostat using a screwdriver.
2. Use a screwdriver to free the metal plate from the back of the thermostat.
3. Use a screwdriver to fix the metal plate into the mounting box.
4. Connect the wiring. The terminals are for Load, Neutral, the Heating Element, and the NTC sensor.
5. Attach the thermostat to the metal plate by securing it with the metal clip and then re-attach the outer frame.
Where is the best place to install the GRAND MEYER HW500I thermostat?
The GRAND MEYER HW500I thermostat must be installed on a wall with free air circulation. It should be positioned so that there is no other influence of a heat source (e.g., the sun), doors, or windows that could influence the ambient temperature reading. The recommended installation height is 1.2 meters from the floor.
What are the important safety instructions for installing the GRAND MEYER HW500I?
WARNING Important Safety Instructions: Disconnect the power supply before carrying out any installation or maintenance work on this unit and associated components. This unit and associated components should only be installed by a competent person (i.e. a qualified electrician). Electrical installation must be in accordance with appropriate statutory regulations.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD GRAND MEYER HW500I (01) PDF DOCUMENT