What are the safety notes regarding damaged GAGGENAU AW 480 appliances?

Damaged appliances must not be operated.

The appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations.

Also observe the assembly instructions!

Connecting cables must not come into contact with hot cooking surfaces.

Do not operate the extractor hood without inserted lamps.

Never operate the appliance without a grease filter.

Hazardous or explosive substances and vapours must not be extracted!

The user is responsible for expert use and the perfect condition of the appliance.

Only operate the appliance under supervision.


What precautions should be taken regarding grease filters and fire risk when using the GAGGENAU AW 480?

Caution! Over-greased filters are a fire risk! Only ever deep-fry under the extractor under constant supervision. Be sure to clean the grease filter on a regular basis and change the activated charcoal filter.

Fire risk! Do not flambé meals under the extractor hood!


When is the operation of the GAGGENAU AW 480 permitted above a hearth for solid fuels?

Operation of the extractor hood above a hearth for solid fuels, which poses a fire risk (e.g. sparks) is only permitted, if the hearth possesses a closed and fixed lid. The current local regulations must be obeyed. This does not apply to gas hobs and gas cookers.


How should hobs be used with the GAGGENAU AW 480?

Hobs may only be used under the extractor hood when pots and pans are placed on them!


What fan level should be used when operating multiple gas rings simultaneously with the GAGGENAU AW 480?

When using more than 3 gas-operated rings at the same time, please operate the extractor hood at level 2 or higher. This prevents a build-up of heat in the appliance.

Note that one large burner of more than 5 kW (Wok) is equivalent to the power of 2 gas burners.

Never operate a gas cooking area without a cooking utensil on it. Regulate the flame in such a way that it does not project over the cooking utensil.


Are heavy objects allowed on the top of the GAGGENAU AW 480?

For safety reasons, do not place any heavy objects on the top of the appliance.


How should the GAGGENAU AW 480 not be cleaned?

Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short-circuits.


How should the GAGGENAU AW 480 be isolated from the mains during maintenance operations?

Isolate the appliance from the mains during every maintenance operation. To do this, remove the mains plug or actuate the corresponding fuse. If the mains plug is not accessible, the appliance must be switched off at fuse point.


Who should carry out repairs on the GAGGENAU AW 480?

Repairs must be carried out by authorised specialists, thus ensuring electrical safety.


What is required for adequate incoming air if the GAGGENAU AW 480 is operated in the same room as a heater or open hearth?

Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed.

Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means.


Will the GAGGENAU AW 480 restart automatically after a power failure?

After a power failure, the extactor will not go on again automatically. You can recommence operation by turning a knob or by pressing any key.


Who should operate the GAGGENAU AW 480?

Never allow children to play with the appliance. Do not let adults or children operate the appliance unsupervised:

– if they are mentally or physically unable to use the appliance safely and correctly,

– if they don’t have the knowledge and experience to use the appliance safely and correctly.


What steps should be taken before operating the GAGGENAU AW 480 for the first time?

Before operating the appliance for the first time, please pay attention to the following notes:

The appliance must be installed and connected by a specialist before it is operated for the first time.

Conscientiously read through the operating and assembly instructions before operating the appliance for the first time.

Remove the packaging from the appliance and dispose of it properly! Pay attention to the fact that there are accessories in the packaging! Keep packaging elements (e.g. plastic foil, styrofoam parts) out of the reach of children!

Thoroughly clean the appliance before using it for the first time (see chapter “Cleaning and care”).

Before operating the appliance for the first time, check that the mains connection is in proper working order.

Check the appliance for transport damage before installing it.


What is the intended use of the GAGGENAU AW 480?

The appliance is intended solely for use in the household and must not be put to any other uses.


What are the control panel features of the GAGGENAU AW 480?

The control panel features are:

0: Motor off

1: Extraction level 1

2: Extraction level 2

3: Extraction level 3

Int: Extraction level intensive

Clock icon: Delayed shut-off

Light bulb icon: Lighting

F: Grease filter saturation display


What special accessories are available for the GAGGENAU AW 480?

You can order the following special accessories:

AA 480-180: Activated carbon filter


What installation accessories are available for exhaust air mode for the GAGGENAU AW 480?

Installation accessories for exhaust air mode:

AD 480-012 for ceiling heights of 2.30-2.70 m

AD 480-022 for ceiling heights of 2.60-3.00 m


What installation accessories are available for circulating air mode for the GAGGENAU AW 480?

Installation accessories for circulating air mode:

AD 480-112 for ceiling heights of 2.30-2.70 m

AD 480-122 for ceiling heights of 2.60-3.00 m


How is the light operated on the GAGGENAU AW 480?

After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green.

The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the light bulb key.

When you briefly press the light bulb key, the lighting is increased up to the maximum level.

You can dim the lighting to the required level by keeping the light bulb key pressed.


How are the fan levels selected on the GAGGENAU AW 480?

Three fan speeds and one intensive speed are available. You set the fan level required for each respective cooking situation by pressing the function selector keys 1, 2, 3 or Int.


When should the intensive level be used on the GAGGENAU AW 480 and how long does it last?

The Int key for the intensive level should be pressed when browning and frying in an open pan.

If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes.

If you press the Int key while the hood is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes.


How can the intensive level be ended before the automatic shut-off on the GAGGENAU AW 480?

If you would like to end the intensive level before the five minutes have elapsed, press the 0 key (“Motor off”) or select a different level. It is possible to switch off the extraction function at any time by pressing the 0 key (motor “off”).


How do I set the intensive level running time on the GAGGENAU AW 480?

You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting. When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2.


How is the delayed shut-off function activated on the GAGGENAU AW 480 and how long does it last?

Delayed shut-off is possible at any level. First press the required key 1, 2, 3 or Int and then press the clock icon key.

The delayed shut-off time for all levels is ten minutes. After these ten minutes, the ventilation switches off, but the lighting stays on.


How is the interval ventilation function activated and deactivated on the GAGGENAU AW 480?

Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key.

This mode of operation is indicated by alternating illumination of the clock icon key together with the corresponding fan level indicator.

You can switch off interval ventilation by pressing the 0 key.


When does the GAGGENAU AW 480 indicate that the grease filters should be cleaned?

The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter. The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash.


How are the stainless steel grease filters of the GAGGENAU AW 480 removed for cleaning?

The stainless steel grease filters can be removed easily for cleaning:

1. Disconnect the power supply (switch off the fuse).

2. Grip the grease filter handle and push the slide towards the rear. Then pull the grease filter downwards out of the holder; repeat the operation for the other grease filters.


How can the stainless steel grease filters of the GAGGENAU AW 480 be cleaned?

You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65°C, where it should be supported vertically to allow food or rinsing residues to drain off.

If possible, the inner parts of the housing should be wiped out in hot rinsing water when replacing the filters.

Caution: when cleaning the inside of the housing, beware of protruding parts.


How are the grease filters re-inserted and the saturation display reset on the GAGGENAU AW 480?

After having cleaned them, re-insert the grease filters in the wall extractor in reverse order.

Important: the handles of both grease filters must be visible after assembly.

Press the F key to set the elapsed hours counter to zero. Flashing of the indicating lamp goes off.


How often should the activated charcoal filter be replaced in the GAGGENAU AW 480 when operating in circulating air mode?

The activated charcoal filter eliminates kitchen smells in the circulating air mode. In normal use (1 to 2 hours daily), the activated charcoal filter must be replaced approximately once a year.

If no activated charcoal filter is installed, kitchen smells will not be eliminated.


How is the activated charcoal filter replaced in the GAGGENAU AW 480?

1. Remove the stainless steel grease filters.

2. Rotate the catches of the activated carbon filter through 90°. Remove the activated carbon filter.

3. Insert the new activated carbon filter at an angle until the rear catch locks into place. Lift the activated carbon filter at the front and rotate the catches through 90°.

4. Re-insert the stainless steel grease filters.

Activated charcoal filters are available through your specialist dealer. Only use original filters.

Activated charcoal filters do not contain any dangerous substances. They can be disposed of through the household refuse collection.


How should the exterior of the GAGGENAU AW 480 extractor hood be cleaned?

Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either.


What is the first step in troubleshooting the GAGGENAU AW 480 in case of malfunction?

In the event of malfunctions, first of all check the household fuses.


What must be done before carrying out any repairs on the GAGGENAU AW 480?

Disconnect the appliance from the mains before carrying out any repairs.


What type of lamp should be used for replacement in the GAGGENAU AW 480?

Defective lamps must only be replaced by lamps of the same type! (12 V/20 W/G4 lampholder)


How should the lamp be replaced in the GAGGENAU AW 480?

Caution: disconnect the power supply before replacing lamps (switch off the fuse)!

Caution: lamps may still be hot shortly after use! Risk of burns.

1. Detach the ring from the lamp cover. Note: make sure that the glass will not fall out.

2. Pull out the lamp.


How is the new lamp inserted in the GAGGENAU AW 480?

1. Insert the lamp in the lampholder. Note: do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its edges.

2. Engage the lamp cover.

3. Connect the appliance to the mains again.


CLICK HERE TO DOWNLOAD GAGGENAU AW 480 (01) PDF DOCUMENT