Click here to download ELKAY ECDFPW314C (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** ECDFPW314C ECDFPWVR314C Installation/CarelUse Manual soft SidesTM Fountains with FLEXI-GUARD@ ECDFPW314C Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICALAND OTHERAPPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. IMPORTANT ALL SERVICE -ro BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. -ro WATER LINES IS ACOMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. 3/8″0.0. UNPLATED 1/4″0.0. TUBE COPPER TUBE CONNECT WATER INLET COLD WATER SUPPLY TO COOLER NOTE: WATER FLOW DIRECTION FIG. 1 OPERATION OF QUICK CONNECT FITTINGS BUILDING WATER INLET SERVICE STOP (NOT FURNISHED) SIMPLY PUSH IN TUBE TO ATTACH FIG. 2 TUBE IS SECURED IN POSITION PUSH IN COLLET TO RELEASE TUBE c PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE 97749C (Rev. K – 1/08)

****** Page 2 ****** ECDFPW314C ECDFPWVR314C ECDFPW314C 406 mm 203mm 5 1/4″ 133mm 203mm 133mm WALL PLATE ASSEMBLY B 6″ 152mm 112″ 13mm 1/4″ (6mm) DIA HOLES FOR MOUNTING PLATE TO WALL BACK PANEL 3/8″ (1 Omm) DIA HOLES FOR MOUNTING PLATE TO WALL (10) 39 9/16″ 1005mm 8″ 203mm 23 1/16″ 586mm 10 3/8″ 264mm 26 7/16″ 672mm 25 3/16″ 640mm 19 314″ 502mm 12 1/8″ 308mm O 9″ 229mm LEGEND 8″ 203mm 42mm 20 3/8″ 518mm 1 1 1 mm 61 Omm D c 476mm 457mm 229mm 9 718″ 251 mm 16mm 3 3/16″ 810mm 17 1/2″ 445mm 12 1/2″ 318mm FINISHED FLOOR A = RECOMMENDED WATER SUPPLY LOCATION 3/8 0.D. UNPLATED COPPER TUBE CONNECT STUBBED 1-112″ (38mm) FROM WALL SHUT OFF BY OTHERS B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″0.0. DRAIN C = 1-1/4″ DRAIN FURNISHED D = OPENING FOR OPTIONALAP-99 ACCESS PANEL. NOTE: REINFORCE THE WALL IN THE SHADED AREAS 97749C (Rev. K – 1/08) PAGE 2

****** Page 3 ****** ECDFPW314C ECDFPWVR314C 1. 2. 3. 4. 5. 6. 7. 8. 9. INSTALLATION INSTRUCTIONS Wall should already be framed for the fountain using the positioning dimensions shown in Figure 3. Shown dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions are required for compliance with ANSI Standard A117.0. Attach wall plate assembly to wall as shown in Figure 3 using 5/16″ x 2″ long bolts and flat washers (not provided). Tighten securely. (Fastener must match wall type, i.e. lag screws for wood studs, bolts and anchors for masonary construction.) Install back panel. Place the upper edge of the panel above hanger on the wall. Slide panel down until it engages the hanger. Be sure back panel is firmly engaged before releasing it. Install rough-in plumbing as shown in Figure 3. Waste line should extend a minimum of 2″ (51 mm) thru the back panel. Run supply water inlet line thru back panel. Install a service stop (not provided). Turn on supply water and flush thoroughly. Remove bottom access panel from fountain basin and save the screws. Install the fountain to the back panel using (4) 5/16″ x 3/4″ long screws and washers (provided) thru holes in back panel. Tighten securely. Cut waste tube to required length using plumbing hardware and a trap (not provided) as a guide. Install hardware and trap. Tighten securely. Make water supply connections from service stop to the 3/8″ O.D. unplated copper tube coming out of the fountain strainer (See Fig. 1). Turn on water supply and check for leaks. Newly installed water supply line should be insulated after leak check is completed. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressure lower than 20 PSIG or higher than 105 PSIG is not covered by warranty. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw on regulator item 1 0 by using a small screwdriver through the small hole in the push button item 3 (See Fig.5). Clockwise adjustment will raise stream height and counter-clockwise adjustment will lower stream height. For best adjustment stream should hit basin approximately 6-1/2″ (165mm) from bubbler. 10. Replace bottom access panel to fountain basin using screws provided. Tighten securely. 1. 2. 3. TROUBLE SHOOTING AND MAINTENANCE Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from orifice with a small round file not over 1/8″ diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials. Stream Regulator: If orifice is free of material deposits, regulate flow according to instruction 9 stated above. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an O-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Figure 2). To insert tubing, push tube straight into the fitting until it reaches a positive stop, approximately 3/4″. PAGE 3 97749C (Rev. K – 1/08)

****** Page 4 ****** ECDFPW314C ECDFPWVR314C ITEM NO. 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 21 2 24 25 26 27 30 29, 30 F)AFRTNO. 40575C 15005C 45662C 45737C 50986C 40322C 56011C 55997C 75580C 61313C 75672C 112627543890 287wc 5501665 28290C 40045C 28824C 100322740560 15W9C 45392C 56092C 28286C 457693 458050, 50074C 62095C 45736C 75541C 111577243890 PARTS LIST DESCRIPTION Drain – Strainer Retaining Nut Push Button Push Button Sleeve Regulator Holder Orifice Assy Housing Assy Pedestal Bubbler Locknut Regulator Cap Screw Screw -#10-24 X PHTC Strainer Fountain Arm – Long Bottom Cover Plate – Long Back Panel Hex Nut Regulator Mounting Bracket Gasket (VR Model Only) Bubbler – Nipple (VR Model Only) Bubbler (VR Model only) Poly Tubing (Cut To Length) Mounting PlateAssy Drain Tailpipe Drain Adapter Gasket – Tail Pipe Tube – Water In Nut-Regulator Mounting Washer – Flat .339/.3591D Steel Screw-Mach. 3 11 4 17 18 7 8 9 2 10 28 FIG. 5 FIG. 6 6 13 5 FIG. 7 21 20 NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 9 OR 20) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN. 14 22 SEE FIG. 5 12 27 SEE FIG 6 OR 7 15 16 23 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 97749C (Rev. K – 1/08) PAGE 4

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ELKAY ECDFPW314C (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.