How do I manually set the clock on my DIGITECH XC0432?

Step 1. Press and hold [CLOCK] button for 2 seconds until “12 or 24Hr” flashes.

Step 2. Use [UP]/[DOWN] button to adjust, and press [CLOCK] button to proceed to the next setting.

Step 3. Repeat Step 2 above for setting of HOUR, MINUTE, SECOND, YEAR, MONTH, DATE, HOUR OFFSET, LANGUAGE and DST.

Note:

1. The unit will automatically exit setting mode if no button was pressed in 60 seconds.

2. Range of hour offset is between -23 and +23 hours.

3. The language options are English (EN), French (FR), German (DE), Spanish (ES), and Italian (IT).

4. For above mentioned “DST” setting, the actual product does not have this feature, as it is Non-RC version.


How do I turn on/off the alarm clock with ice-alert function on my DIGITECH XC0432?

Step 1. Press the [ALARM] button anytime to show the alarm time.

Step 2. Press [ALARM] button to activate the alarm.

Step 3. Press again to activate alarm with ice-alert function.

Step 4. To disable the alarm, press until the alarm icon disappears.


How do I set the alarm time on my DIGITECH XC0432?

Step 1. Press and hold [ALARM] button for 2 seconds to enter alarm setting mode. HOUR will begin to flash.

Step 2. Use [UP]/[DOWN] button to adjust HOUR, and press [ALARM] button to proceed to set MINUTE.

Step 3. Repeat Step 2 above to set MINUTE, then press [ALARM] button to exit.

Note: Pressing the [ALARM] button twice when alarm time is being displayed will activate the temperature-adjusted pre-alarm. The alarm will sound 30 minutes earlier if it detects outside temperature is below -3°C.


How do I select the display mode for the barometer on my DIGITECH XC0432?

Press and hold [BARO] button for 2 seconds to toggle between:

  • ABSOLUTE: the absolute atmospheric pressure of your location
  • RELATIVE: the relative atmospheric pressure based on the sea level

How do I set the relative atmospheric pressure value on my DIGITECH XC0432?

Step 1. Get the atmospheric pressure data of the sea level (it is also the relative atmospheric pressure data of your home area) through the local weather service, internet and other channels.

Step 2. Press and hold [BARO] button for 2 seconds until “ABSOLUTE” or “RELATIVE” icon flashes.

Step 3. Press [UP]/[DOWN] button to switch to “RELATIVE” mode.

Step 4. Press [BARO] button once again until the “RELATIVE” atmospheric pressure digit flashes.

Step 5. Press [UP]/[DOWN] button to change its value.

Step 6. Press [BARO] button to save and exit the setting mode.

Note:

1. The default relative atmospheric pressure value is 1013 mb/hPa (29.91 inHg), which refers to the average atmospheric pressure.

2. When you change the relative atmospheric pressure value, the weather indicators will change along with it.

3. The built-in barometer can notice the environmental absolute atmospheric pressure changes. Based on the data collected, it can predict the weather conditions in the forthcoming 12 hours. Therefore, the weather indicators will change according to the detected absolute atmospheric pressure after you operate the clock for 1 hour.

4. The relative atmospheric pressure is based on the sea level, but it will change with the absolute atmospheric pressure changes after operating the clock for 1 hour.


How do I select the measurement unit for the barometer on my DIGITECH XC0432?

Step 1. Press the [BARO] button to enter unit setting mode.

Step 2. Use the [BARO] button to change the unit between inHg (inches of mercury) / mmHg (millimeter of mercury) / mb (millibars per hectopascal) /hPa.

Step 3. Press [BARO] button to confirm.


How do I select the rainfall display mode on my DIGITECH XC0432?

The device displays how many mm / inches of rain are accumulated in a one hour time period, based on current rainfall rate.

Press [RAINFALL] button to toggle between:

  • RATE: Current rainfall rate in past an hour
  • DAILY: The DAILY display indicate the total rainfall from midnight
  • WEEKLY: The WEEKLY display indicate the total rainfall from the current week
  • MONTHLY: The MONTHLY display indicate the total rainfall from the current calendar month

Note: Rain rate is updated every 6 minutes, at every hour on the hour, and at 6, 12, 18, 24, 30, 36, 42, 48, 54 minute past the hour.


How do I select the measurement unit for the rainfall on my DIGITECH XC0432?

Step 1. Press and hold [RAINFALL] button 2 seconds to enter unit setting mode.

Step 2. Use [UP] / [DOWN] button to toggle between mm (millimeter) and in (inch).

Step 3. Press [RAINFALL] button to confirm and exit.


How do I read the wind direction on my DIGITECH XC0432?

Wind Direction Indicator Meaning

Real-time wind direction

Wind directions appeared in last 5 minutes (max 6)


How do I select the wind display mode on my DIGITECH XC0432?

Press [WIND] button to toggle between:

  • AVERAGE: The AVERAGE wind speed will display the average of all wind speed numbers recorded in the previous 30 seconds
  • GUST: The GUST wind speed will display the highest wind speed recorded from last reading

The wind level provides a quick reference on the wind condition and is indicated by a series of text icons:

Level LIGHT MODERATE STRONG STORM
Speed 2-8 mph 3-13 km/h 9-25 mph 14-41 km/h 26-54 mph 42-87 km/h ≥ 55 mph ≥ 88 km/h

How do I select the wind speed unit on my DIGITECH XC0432?

Step 1. Press and hold [WIND] button for 2 seconds to enter unit setting mode.

Step 2. Use the [UP] / [DOWN] button to change the unit between mph (miles per hour) / m/s (meter per second) / km/h (kilometer per hour) / knots.

Step 3. Press [WIND] button to confirm and exit.


How do I view Wind Chill on my DIGITECH XC0432?

Press the [INDEX] button repeatedly until WINDCHILL displays.

Note: The wind chill factor is based on the combined effects of temperature and wind speed. The wind chill displayed is calculated solely from temperature and humidity measured from the 5-in-1 sensor.


How do I view Heat Index on my DIGITECH XC0432?

Press the [INDEX] button repeatedly until HEAT INDEX displays.

Heat Index range Warning Explanation
27°C to 32°C (80°F to 90°F) Caution Possibility of heat exhaustion
33°C to 40°C (91°F to 105°F) Extreme Caution Possibility of heat dehydration
41°C to 54°C (106°F to 129°F) Danger Heat exhaustion likely
≥55°C (≥130°F) Extreme Danger Strong risk of dehydration / sun stroke

Note: Heat index is only calculated when temperature is 27°C/80°F or above, and based solely from the temperature and humidity measured from the 5-in-1 sensor.


How do I view Dew-Point (Indoor) on my DIGITECH XC0432?

Press the [INDEX] button repeatedly until DEWPOINT displays.

Note: The dew point is the temperature below which the water vapor in air at constant barometric pressure condenses into liquid water at the same rate at which it evaporates. The condensed water is called dew when it forms on a solid surface. The dewpoint temperature is calculated from the indoor temperature and humidity measured at the Main Unit.


How do I access history data (all records in the past 24 hours) on my DIGITECH XC0432?

The Display main unit automatically record and display data of past 24 hours on the hour.

To check all the history data in the past 24 hours, press the [HISTORY] button.

E.g. Current time 7:25 am, Mach 28

Press [HISTORY] button repeatedly to view past readings at 7:00am, 6:00am, 5:00am, 5:00am (Mar 27), 6:00am (Mar 27), 7:00am (Mar 27)

The LCD will display the past indoor and outdoor temperature & humidity, value of air pressure, wind chill, wind speed, rainfall and their time and date.


How do I use the maximum / minimum memory function on my DIGITECH XC0432?

Step 1. Press [MAX/MIN] button to check the maximum/minimum records. The checking orders will be: Outdoor max temperature → Outdoor min temperature → Outdoor max humidity → Outdoor min humidity → Indoor max temperature → Indoor min temperature → Indoor max humidity → Indoor min humidity → Outdoor max wind chill → Outdoor min wind chill → Outdoor max heat index → Outdoor min heat index → Indoor max dewpoint → Indoor min dewpoint → Max pressure → Min pressure → Max average → Max gust → Max rainfall.

Step 2. Press and hold [MAX/MIN] button for 2 seconds to reset the maximum and minimum records.

Note: When maximum or minimum reading is displayed, the corresponding timestamp will be shown.


What are the HI/LO alert areas and types available on my DIGITECH XC0432?

HI/LO alert are used to alert you of certain weather conditions. Once activated, the alarm will turn on and amber LED starts flashing when a certain criterion is met. The following are areas and type of alert provided:

Area Type of Alert available
Indoor temperature HI and LO alert
Indoor humidity HI and LO alert
Outdoor temperature HI and LO alert
Outdoor humidity HI and LO alert
Rainfall HI alert *
Wind speed HI alert

Note: * Daily rainfall since midnight.


How do I set the HI / LO alert on my DIGITECH XC0432?

Step 1. Press the [ALERT] button until the desired area is selected.

Step 2. Use [UP] / [DOWN] buttons to adjust the setting.

Step 3. Press [ALERT] button to confirm and continue to next setting.


How do I enable/disable the HI / LO alert on my DIGITECH XC0432?

Step 1. Press [ALERT] button until the desired area is selected.

Step 2. Press [ALARM] button to turn the alert on or off.

Step 3. Press [ALERT] button to continue to next setting.

Note:

1. The unit will automatically exit setting mode in 5 seconds if no button is pressed.

2. When ALERT alarm is on, the area and type of alarm that triggered the alarm will be flashing and the alarm will sound for 2 minutes.

3. To silence the Alert alarm beeping, press the [SNOOZE / LIGHT] / [ALARM] button, or let the beeping alarm automatically turn off after 2 minutes.


What are the comfort indications for my DIGITECH XC0432?

The comfort indication is a pictorial indication based on indoor air temperature and humidity in an attempt to determine comfort level.

Too cold / too dry Comfortable Too warm / too humid
Icon

Note:

1. Comfort indication can vary under the same temperature, depending on the humidity.

2. There is no comfort Indication when temperature is below 0°C (32°F) or over 60°C (140°F).


How do I clear data on my DIGITECH XC0432?

During installation of the wireless 5-in-1 sensor, the sensors were likely to be triggered, resulting in erroneous rainfall and wind measurements. After the installation, user may clear out all the erroneous data from the Display Main Unit, without needing to reset the clock and re-establish pairing.

Simply press and hold the [HISTORY] button for 10 seconds. This will clear out any data recorded before.


How do I point the 5-in-1 sensor to the South on my DIGITECH XC0432?

The outdoor 5-in-1 sensor is calibrated to be pointing to North by default. However, in some cases, users may wish to install the product with the arrow pointing towards the South, especially for people living in the Southern hemisphere (e.g. Australia, New Zealand).

Step 1. First install the outdoor 5-in-1 sensor with its arrow pointing to the South. (Please refer to Installation session for mounting details)

Step 2. On the Display main unit, press and hold [WIND] button for 8 seconds until the upper part (Northern Hemisphere) of the compass lights up and blinking.

Step 3. Use [UP] / [DOWN] to change to lower part (Southern Hemisphere).

Step 4. Press [WIND] button to confirm and exit.

Note: Changing from hemisphere setting will automatically switch the direction of the moon phase on the display.


How do I clean the rain collector on my DIGITECH XC0432?

Step 1. Rotate the rain collector by 30° anticlockwise.

Step 2. Gently remove the rain collector.

Step 3. Clean and remove any debris or insects.

Step 4. Install all the parts when they are fully clean and dried.


How do I clean the Thermo / Hygro sensor on my DIGITECH XC0432?

Step 1. Unscrew the 2 screws at the bottom of the radiation shield.

Step 2. Gently pull out the shield.

Step 3. Remove carefully any dirt or insects inside the sensor casing (Do not let the sensors inside get wet).

Step 4. Clean the shield with water and remove any dirt or insects.

Step 5. Install all the parts back when they are fully clean and dried.


What should I do if my DIGITECH XC0432 shows strange or no measurement of the Rain Sensor?

Step 1. Check the drain hole in the rain collector.

Step 2. Check the balance indicator.


What should I do if my DIGITECH XC0432 shows strange or no measurement of the Thermo / Hygro Sensor?

Step 1. Check the radiation shield.

Step 2. Check the sensor casing.


What should I do if my DIGITECH XC0432 shows strange or no measurement of Wind Speed and Direction?

Step 1. Check wind cups (Anemometer).

Step 2. Check the wind vane.


What should I do if my DIGITECH XC0432 shows a signal lost for 15 minutes or 1 hour?

Step 1. Relocate the main unit and 5-in-1 sensor closer to each other.

Step 2. Make sure the main unit is placed away from other electronic appliances that may interfere with the wireless communication (TVs, computers, microwaves).

Step 3. If problem continues, reset both main unit and 5-in-1 sensor.


What precautions should I take when using my DIGITECH XC0432?

  • Read and keep these instructions
  • Heed all warnings
  • Follow all instructions
  • Do not subject the unit to excessive force, shock, dust, temperature or humidity
  • Do not cover the ventilation holes with any items such as newspapers, curtains etc
  • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth
  • Do not clean the unit with abrasive or corrosive materials
  • Do not tamper with the unit’s internal components. This invalidates the warranty
  • Only use fresh batteries. Do not mix new and old batteries
  • Only use attachments / accessories specified by the manufacturer
  • Images shown in this manual may differ from the actual display
  • When disposing of this product, ensure it is collected separately for special treatment
  • Placement of this product on certain types of wood may result in damage to its finishing for which manufacture will not be responsible. Consult the furniture manufacturer’s care instructions for information.
  • The contents of this manual may not be reproduced without the permission of the manufacturer
  • When replacement parts are required, be sure the service technician uses replacement parts specified by th manufacturer that have the same characteristics as the original parts. Unauthorized substitutions may result in fire, electric shock, or other hazards.
  • Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for specia treatment is necessary.
  • Please note that some units are equipped with a battery safety strip. Remove the strip from the batter compartment bef first use.
  • The technical specifications for this product and the contents of the user manual are subject to change without notice.

What are the specifications of the main unit for the DIGITECH XC0432?

MAIN UNIT
Dimensions (W x H x D) 120 x 190 x 22 mm
Weight 370g with batteries
Battery 3 x AA size 1.5V batteries (Alkaline batteries recommended)
Support channels Wireless 5-in-1 sensor (Wind speed, Wind direction, Rain gauge, thermo-hygro)
RF Frequency 917Mhz

What are the indoor barometer specifications for the DIGITECH XC0432?

INDOOR BAROMETER
Barometer unit hPa, inHg and mmHg
Measuring range (540 to 1100 hPa) / (405 – 825 mmHg) / (15.95 – 32.48 inHg)
Resolution 1hPa, 0.01inHg, 0.1mmHg
Accuracy (540 – 699hPa ± 8hPa @ 0-50°C) / (700 – 1100hPa ± 4hPa @ 0-50°C) (405 – 524 mmHg ± 6mmHg @ 0-50°C) / (525 – 825 mmHg ± 3mmHg @ 0-50°C) (15.95 – 20.66inHg ± 0.24inHg @ 32-122°F) / (20.67 – 32.48inHg ± 0.12inHg @ 32-122°F)
Weather forecast Sunny/Clear, slightly Cloudy, Cloudy, Rainy, Rainy / Stormy and Snowy
Display modes Current, Max, Min, Historical data for last 24hrs
Memory modes Max & Min from last memory reset (with time stamp)

What are the indoor temperature specifications for the DIGITECH XC0432?

INDOOR TEMPERATURE
Temp. unit °C or °F
Operating range -10°C to 50°C (14°F to 122°F)
Resolution 1 decimal place
Accuracy +/- 1°C or 2°F typical @ 25°C (77°F)
Display modes Current, Min and Max, Historical data for past 24 hours
Memory modes Max & Min from last memory reset (with time stamp)
Alarm Hi/Lo Temperature Alert

What are the indoor humidity specifications for the DIGITECH XC0432?

INDOOR HUMIDITY
Operating range 20% to 90%RH (< 20%: LO; > 90%: HI) (Temperature between 0°C to 60°C)
Resolution 1%
Accuracy +/-5% typical @ 25°C (77°F)
Display modes Current, Min and Max, Historical data for past 24 hours
Memory modes Max & Min from last memory reset (with time stamp)
Alarm Hi/Lo Humidity Alert

What are the clock specifications for the DIGITECH XC0432?

CLOCK
Clock display HH:MM:SS / Weekday
Hour format 12hr AM/PM or 24hr
Calendar DD/MM/YR or MM/DD/YR
Weekday in 5 languages EN, FR, DE, ES, IT
Hour offset -23 to +23 hours

What are the wireless 5-in-1 sensor specifications for the DIGITECH XC0432?

WIRELESS 5-IN-1 SENSOR
Dimensions (W x H x D) 343.5 x 393.5 x 136 mm
Weight 673g with batteries
Battery 3 x AA size 1.5V battery (Alkaline batteries recommended)
Frequency 917 MHz
Transmission Every 12 seconds

What are

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DIGITECH XC0432 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.