CPE COMPUTE-A-CHARGE CC220E (01) Image

FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF USER GUIDE
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF USER MANUAL
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF OWNER GUIDE
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF OWNER MANUAL
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF REFERENCE GUIDE
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF INSTRUCTION GUIDE
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF REFERENCE MANUAL
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF INSTRUCTION MANUAL
FREE ENGLISH CPE COMPUTE-A-CHARGE CC220E (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD CPE COMPUTE-A-CHARGE CC220E (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What is the Compute-A-Charge CC220E?

The Compute-A-Charge CC220E is a battery operated, precision scale with a visual charge and recover alarm feature, for weighing, charging and recovering refrigerants used in HVAC/R systems.


What are the key features of the CC220E?

  • Weight Capacity – 220 lb (100 kg)

  • Weight Accuracy – 0.015% of reading [or +/- selected resolution, whichever greater]

  • Display Resolution (Selectable) – User can select from 4 different increments (see specifications)

  • Continuous Battery Life – One 9V = 75 hours; Two 9V (included) = 150 hours

  • 7 Button Keypad – Easy to navigate

  • Charge / Recover Visual Alarm Feature – Alerts user when approaching programmed charge amount or overfill limit

  • Auto-Power Off (APO), – To conserve battery power, and when not in use, the scale can be set to turn OFF after any of 5 different time increments (see specifications)

  • Smart Awake Feature – Displays weight at time of Auto-Off


How do I use the 7-button keypad?

The 7-button keypad functions are as follows:

1. POWER KEY

  • Press to turn power ON or OFF.

2. UNITS KEY

  • Press to select your desired weight unit (LB to KG, or KG to LB).

3. TARE KEY

  • While in WEIGH mode – Press to Tare (“zero out”) the scale display.

  • While in HOLD mode – Tare function is not active.

  • While in CHARGE/RECOVER mode – Resets programmed amount to 0.

4. GO/HOLD KEY

  • Starts CHARGE or RECOVER modes (per data entered after pressing the Set key).

  • While running in CHARGE or RECOVER modes, pressing this key will place the CC220E into HOLD (pause).

5. SET/RESET KEY

  • There are 5 modes to select and/or where information can be entered: Scale (Weigh), Charge, Recover, APO, Resolution.

  • Press to scroll through different modes.

  • Press while in any mode to terminate and return to SCALE mode.

6. UP KEY

  • Increases the weight displayed (one resolution unit) for every actuation, or if continuously pressed.

7. DOWN KEY

  • Decreases the weight displayed (one resolution unit) for every actuation, or if continuously pressed. A visual reminder will flash if the display reaches 0.


What are the general safety instructions for using the CC220E?

Please read, follow and understand the contents of this entire manual, with special attention given to Danger, Warning and Caution statements.

FOR USE BY PROFESSIONALLY TRAINED AND CERTIFIED OPERATORS ONLY. MOST STATES, COUNTRIES, ETC., MAY REQUIRE USER TO BE LICENSED. PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY.

DANGER: Overfilling a recovery tank may cause a violent rupture resulting in severe injury or even death. As a minimum, please use a scale to continuously monitor recovery tank weight.

WARNING: All hoses may contain liquid refrigerant under pressure. Contact with refrigerant may cause frostbite or other related injuries. Wear proper personal protective equipment such as safety goggles and gloves. When disconnecting any hose, please use extreme caution as high pressure refrigerant may be present.

WARNING: Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high concentration levels may cause heart arrhythmia, loss of consciousness, or even cause suffocation. Exposure may irritate eyes, nose, throat and skin. Please read manufacturer’s Material Safety Data Sheet for further safety information on refrigerants and lubricants.

WARNING: Make certain all safety devices are functioning properly before operating equipment.

CAUTION: To avoid cross contamination of refrigerant and potential leakage to the atmosphere, proper hoses and fittings should be used and checked for damage.

CAUTION: To avoid overfilling refrigerant tank, read and follow manufacturer’s recommended filling instructions for refrigerant being recovered and constantly monitor the scale display.

CAUTION: Mixing of different refrigerants will cause your recovered supply of refrigerant to become contaminated.

CAUTION: The user must monitor the scale display and turn ON/OFF manifold and/or tank valves at appropriate times so that the proper amount of refrigerant is recovered (into the tank) or removed (from the tank).


What are the specifications of the CC220E?

Specification Value
Maximum Load: 220 lb (100 kg) capacity
Weight Accuracy: 0.015% of reading or +/- selected resolution, whichever greater
Display Resolution (Increments): Selectable: 0.1 oz (2 g); 0.2 oz (5 g); 0.25 oz (10 g); or 0.50 (25 g)
Battery Life: One 9V = 75 hrs.; Two 9V = 150 hrs.
Power Source: One or two (included) 9V Alkaline batteries.
Battery Status Indicator: 3 segment symbol
Control Type: Handheld LCD display
Control Mount: Magnetic back, with 360° swivel hook
Cord: 6′ (1.8 m) flexcord, extended
Auto Power Off (Enabled): Default = Display Turns OFF After 10 Minutes Inactivity (Can re-set in increments of 5, 10, 15, 30, 60 mins or OFF)
Auto Power Off (Disabled): Display shows “APO OFF” at power up [Display will be constant ON]
Smart Awake: Displays weight at time of Auto-off
Weight Readout: lb. / oz. or kg / g
Operating Temperature Range: 14°F to 122°F (-10°C to 50°C)
Overload Protection: Mechanical and visual
Unit Weight (Including Case): 5.68 lb (2.6 kg)
Platform Dimensions: 8.75″ x 8.75″ (22.3 x 22.3 cm)
Calibration: National Institute of Standards & Technology (U.S.)
Approvals CE

What do the LCD display abbreviations mean?

The LCD display abbreviations are as follows:

MODES TO SELECT DISPLAY ABBREVIATIONS
SCL= Scale
CHg = Charge
rEC = Recover
rES = Resolution
APO = Automatic Power OFF
WHEN IN CHARGE MODE c = Charge (tracking) in process
F = Final programmed charge achieved
WHEN IN RECOVER MODE t OFF: Ensure tank NOT on scale
t ON: Place tank ON scale
r = Recovery (tracking) in process
o = Tank overfilled
n = Net gain of one or more tanks
WHEN IN CHARGE OR RECOVER MODE h = Hold (pause) refrigerant tracking
WHEN IN ANY MODE OL= Overload (Reduce load immediately)

How do I set up the scale?

Follow these steps to set up the scale:

A. Remove scale from storage case and place on level, rigid surface.

B. Install one or two (included) 9V batteries in back of control.

C. Press power (icon) to turn scale ON.

D. APO (Automatic Power Off). 5 minutes = default setting [you may also select 10, 15, 30, 60 mins, or turn APO OFF].

E. DISPLAY RESOLUTION: Default is 0.2 Oz (5g). Press UP/DOWN arrows until desired value found. Press GO/HOLD to select. See specifications table for other selectable values.

F. WEIGHT UNITS: Press LB/KG to select.


How do I use the scale in WEIGH mode (“SCL”)?

Follow these steps to use the scale in WEIGH mode:

1. Place refrigerant tank on scale.

2. Default mode is “SCL” (weigh).

3. View GROSS weight on display.

4. Remove tank from platform after weight observed.

5. Display will flash if maximum weight capacity (220 Lb/100 kg) exceeded.


How do I use the scale in CHARGE mode (“CHg”)?

Follow these steps to use the scale in CHARGE mode:

1. Place refrigerant tank on scale.

2. Connect equipment per DIAGRAM A (CHARGE).

3. Press SET/RESET to scroll through the menu and choose CHARGE “Chg”.

4. Use UP/DOWN arrows to input desired weight (charge amount to be tracked), then press GO/HOLD.

5. Once tank and manifold valves are opened, the charge (tracking) session will begin. The display will show a small “c” indicating “charge” and how much refrigerant has been charged into your system (removed from the refrigerant tank).

6. During charging, screen characters will eventually flash at an increasing rate, showing that the programmed charge amount is closer to being reached.

  • HOLD – Pressing GO/HOLD while charging will PAUSE charge tracking, allowing the user tighten hoses, change tanks if necessary, but continue later without losing track of the NET amount charged.

  • SET/RESET – Pressing SET/RESET during charge operation will stop/cancel the charge from being tracked. The normal WEIGH Mode will resume.

  • NOTE: So that the actual charged vs. tracked amounts align, remember to physically stop charging by closing tank and/or manifold valves before pressing HOLD.

  • GO/HOLD – After any adjustments are made, the accumulated amount being tracked can be resumed by pressing GO/HOLD.

7. When programmed charge amount (weight) has been reached, the screen will flash a large “F” (FINAL). Quickly close tank and/or manifold valves.

8. SHUT DOWN – When CHARGE function done, turn off recovery machine, close valves, remove cylinder from platform. Press POWER to turn scale OFF.


How do I use the scale in RECOVER mode (“rEC”)?

Follow these steps to use the scale in RECOVER mode:

DO NOT PLACE TANK ON SCALE (AT THIS TIME)

1. Connect equipment per DIAGRAM B (RECOVER).

2. Press SET/RESET to scroll through menu and choose Recovery “rEC”.

3. For tank you will use, press UP/DOWN arrows to input tank maximum refrigerant weight capacity stamped on the tank collar (0.8 X WC + TW), then press GO/HOLD.

  • WC = Water Capacity (weight);

  • TW = Tank Weight (of empty tank)

CAUTION: DO NOT PLACE TANK ON PLATFORM BEFORE STEP 5. DOING SO COULD LEAD TO OVERFILLING THE REFRIGERANT TANK. DANGER – THE RECOVERY TANK CONTAINS LIQUID REFRIGERANT. OVERFILLING OF THE RECOVERY TANK MAY CAUSE A VIOLENT EXPLOSION RESULTING IN SEVERE INJURY OR EVEN DEATH.

4. TANK OFF

When “t OFF” appears ensure tank is NOT on scale, press GO/HOLD.

5. TANK ON

When “t ON” appears, place tank on scale, press GO/HOLD, open valves and turn ON Recovery Machine (follow manufacturer’s instructions) to start recovery.

6. REMAINING CAPACITY OF TANK

Display will show “r” indicating recovery in process, alongside the remaining tank refrigerant weight capacity (until full.) Display will count backwards from remaining tank capacity (indicating decreasing capacity of tank).

7. TANK FILL LIMIT REACHED (OR EXCEEDED)

While recovering refrigerant, be ready to turn OFF recovery machine and/or CLOSE valves, while constantly monitoring the display so that the tank will NOT be overfilled. Characters will flash if tank overfill has occurred and a “negative” symbol will appear next to the “o” symbol, indicating the tank has been overfilled by the amount indicated on the display.

7.1 If characters flash, the user may press GO/HOLD once to stop the flashing. Turn OFF recovery machine and/or CLOSE valves. The user may change tanks then press GO/HOLD again to restart recovery tracking.

8. HOLD FUNCTION

At any point during recovery, pressing GO/HOLD will activate the HOLD function. During HOLD indicated by “h”, the remaining tank capacity will update if the weight is changed, but the net gain will not account for any additional recovery during hold.

NOTE: Remember to physically stop recovering refrigerant by closing tank and/or manifold valves while activating HOLD.

9. NET GAIN

At any point during refrigerant recovery, pressing and holding UP/DOWN arrows will show the net gain indicated by “n”. The recovery feature will track the net gain during the recovery session (except during Hold), including even after overfill is reached, so that the exact total net gain will be known.

10. IF RECOVERING REFRIGERANT INTO MORE THAN ONE TANK

If recovering refrigerant into more than one tank, of the same capacity, without reaching overfill, press GO/HOLD during recovery, turn off recovery machine and close valves. Then change the tank, then press GO/HOLD again to restart recovery tracking.

10.1 The NET Gain will continue to track the recovery of this session, until SET/RESET is pressed.

11. SHUT DOWN – When RECOVER function complete, close valves, turn OFF recovery machine (follow manufacturer’s instructions) and remove tank from scale. Press POWER until display turns off.


How do I interpret the battery level indicator?

The battery indicator is shown on the LCD as a battery shape with a 3 segment icon:

  • (3) segments on bar graph: Battery level higher than 66%

  • (2) segments on bar graph: Battery level between 33% to 66%

  • (1) segments on bar graph: Battery level between 10% to 33%

  • (0) segments on bar graph: Battery level between 3% to 10%

  • (0) segments on bar graph, blinking: Battery level below 3%

  • LO CELL displayed on LCD: Battery depleted, powering down