What do the safety signal words used in this manual mean?
Danger: Means if the safety information is not followed the likelihood that the operator or bystanders will be seriously injured or killed is very high.
Warning: Means if the safety information is not followed the operator or bystanders could be seriously injured or killed.
Caution: Means if the safety information is not followed the operator, or bystander may be injured or the vacuum machine maybe damaged.
What are the general warnings for operating the Pulse-Bac®?
To reduce the risk of fire, electrical shock, or injury, read and understand the owners manual and all labels on the Pulse-Bac® before operating. Use the Pulse-Bac only as described in this manual.
Your Pulse-Bac® is designed to vacuum dry material only. Never use the machine to vacuum liquids of any kind.
What should I know about static shocks when using the Pulse-Bac®?
Static Shocks are common and occur in dry areas or when the relative humidity of the air is low. Be aware of low humidity conditions and if static shocks are persistent, order a static proof vacuum hose to reduce static shock. CDCLarue™ recommends anyone using a Pulse-Bac for collecting wood dust to always use a static reduction hose. Keep in mind wood particles create static electricity even when the humidity is normal.
What should I know about extension cord usage for the PB-1050, PB-1150, or PB-1250?
When using an extension cord to operate your PB-1050, PB-1150, or PB-1250 always use the proper size extension cord. The chart below will help you in your selection of extension cords. Please note, not using the proper size of extension cord can cause damage to electrical and motor components. Not using the proper extension cord may cause the warranty to be voided.
What is the proper extension cord gauge and length?
| Extension Cord Length | Wire Gauge (A.W.G.) |
|---|---|
| 0-25 Ft. | 12 |
| 50 ft. | 10 |
How do I unpack and check the carton contents?
1. Remove the vacuum and its contents from the shipping carton or cartons.
2. Check each item against the packing list.
3. Contact your carrier if any items are damaged or missing. If you require additional help contact CDCLarue™ customer services at (918)-216-6100.
How do I empty the vacuum collection tank?
WARNING: To reduce the risk of injury from accidental starting, turn the vacuum off and unplug the power cord before emptying the collection tank.
1. To remove top hood assembly from the collection tank, simply unlatch the two latches on either side of the collection tank and lift the top hood off the tank. Set the top hood assembly down on top of the filters.
2. Take hold of the top of the collection tank with one hand, lift the tank with the handle at the center bottom of the tank, and with your other hand, dump the contents into the proper waste disposal container.
What is the warning regarding lifting the collection tank?
WARNING: To reduce the risk of back injury or falls, do not lift a collection tank heavy with dust and debris. Scoop enough contents out to make the collection tank light enough for one person to lift comfortably.
What maintenance is required for the Pulse-Bac®?
The Pulse-Bac® requires little or no preventive maintenance; however the performance of the three cartridge filtration system can be enhanced by allowing the PB-1050 / PB-1150 / or PB-1250 to run for 3 to 5 minutes after each days use. The cartage filters should never be removed for cleaning. The only time the filters should be removed is when replacing old filters with new filters. Removing the filters for cleaning is highly discouraged as this action may cause many problems. If filters are not replaced properly damage can occur. For proper operation when using a Pulse-Bac® vacuum for dust collection, filters should be changed a minimum twice a year.
How can I enhance the performance of the filtration system?
Although the Pulse-Bac® cleans its filters continuously during operation, small amounts of debris will cling to the surface of the filters under normal operating conditions. Operating the PB-1050, PB-1150, or PB-1250 for three to five minutes before and after each day’s use will help the filters to purge themselves of most dust and debris. This extra step will help to extend the life of the filters, enhance performance, and reduce operating cost.
What are the operating and safety tips for the Pulse-Bac®?
• Never operate in a wet environment.
• Never operate with an ungrounded power source.
• Never operate with an improper or ungrounded electrical extension cord.
• Never operate unattended.
• Never vacuum hot ashes or combustible materials.
• Never operate in conjunction with any ungrounded equipment.
• Always use a proper 120 volt 20 amp electrically protected outlet to operate.
• To reduce risk of electrical shock, do not expose to rain and always store indoors.
• Never operate the Pulse-Bac in the presence of explosive vapors.
• Always unplug the Pulse-Bac when not in use and before servicing.
• Turn your Pulse-Bac off before unplugging from the power source.
• Never operate the Pulse-Bac from a generator that is not earth grounded.
What is the warning regarding sparks and flammable materials?
WARNING: Sparks generated by the vacuum motor can ignite flammable vapors or dust.
To reduce the risk of fire or explosion: Never vacuum or use the machine near flammable or combustible liquids, gases, or explosives fluids like gasoline, lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, coal dust, magnesium dust, grain dust, gun powder or other types of flammable vapors or fuels.
How do I install the filters on the Pulse-Bac®?
When you receive your new Pulse-Bac® you will be required to install the filters onto the vacuum head. Follow these instructions (1) thru (5) to insure proper filter installation.
1. If not already installed, install the O-Ring (P/N # 401979) onto the O-Ring groove at the top of the twist on filter as shown in figure 1.
2. If not already installed, install the foam Dust Ring (P/N # 403242) into the outer groove of the filter.
NOTE: The foam dust ring helps to prevents dust from accumulating between the top of the filter and the filter receiver, it doesn’t create a seal for the filter. The O-Ring is the only seal for the filter.
3. Check to ensure that the filter receiver is clean and void of any dust or foreign material before screwing your filter into place.
4. Insert the filter into the filter receiver and twist in a clockwise direction until the filter just touches the base, then turn the filter one quarter turn to tightly secure it.
5. Once the filters have been installed, the vacuum is ready to be put into service.
What is the caution regarding removing installed filters?
Caution: Once you have installed the filters on the Pulse-Bac, the filters should never be removed unless they are to be replaced. Removing the filters after initial installation can cause various problems if not reinstalled properly. Since your new Pulse-Bac cleans its filters automatically, you should never have reason to remove the filters other than for replacement.
What should I do if I need help installing filters?
If you need assistance or require additional information when installing the filters, you can contact CDCLarue customer services department at (918) 216-6100. We will put you in contact with a technician that can help you accomplish the installation and answer any questions you may have.
How do I test the solenoids using a VOM?
• Locate the printed circuit board and the wiring for the solenoids. (see pictorial #2)
• You will need to use your volt ohm meter (VOM) to determine which if any of the solenoids is defective. Set your VOM to ohms using a scale of 200 ohms or less. Be sure to zero your meter before taking your readings.
• Turn to page #9 of this manual for the location and identification of test points on the printed circuit board.
• Connect your VOM negative test lead to the point on the solenoid connection block on the printed circuit marked ( SC ) or solenoid common.
• Connect your positive lead to points one, two and three individually on the solenoid connection block. Your VOM should read approximately 22 ohms at each test point if the solenoid is good and infinity or zero if the solenoid is bad. (see pictorial #2)
What should I do if I have a bad solenoid?
If you have a bad solenoid, you will need to remove the motor and its motor mount to gain access to the bad solenoids. You can determine which solenoid to replace by noting the color of the wire when taking readings from the solenoid connection block on the PCB. See page #13 for details on removing the motor and the motor mount.
How do I replace a bad solenoid?
• Once you determine which solenoid to replace, disconnect the solenoid from the valve stem by removing the retaining clip on the retaining pin then remove the retaining pin to release the solenoid plunger from the valve stem. Do not use the old solenoid plunger or remove the valve to replace the bad solenoid.
• Remove the solenoid control wires by removing the quick connect connectors and remove the four Phillips screws holding the solenoid to the solenoid mounting plate by using a small #4 Phillips screw driver.
• Replace the bad solenoid by reversing the above directions used to remove the solenoid.
What precautions should be taken when installing a new solenoid?
When installing the new solenoid make sure you use lock tight on the Phillips screws holding the solenoid to the solenoid mounting plate. If you do not lock tight the screws holding the Solenoid to the solenoid mounting plate they may come loose and go through the motor fan causing irreversible damage.
Who should I contact if I need help replacing a solenoid?
If you require help when replacing a solenoid, you can contact CDCLarue™ service department for support or conformation of details relating to the replacement of your solenoids.
How do I replace the Printed Circuit Board (PCB)?
• Disconnect the Pulse-Bac® from the electrical power source.
• Remove the hood cover by removing the four 5/16″ X 10 X 3/4″ screws holding it to the base plate. (see pectoral #1)
• Before completely removing the hood disconnect the wiring to the power switch (sensor alarms, and alarm LED light if equipped) by disconnecting the Molex connectors which connects the wiring to the main base plate of the Pulse-Bac.
• Locate the four 8/32 x 1/2″ screws holding the PCB to the electrical assembly and remove them and let the board float free.
• Disconnect the six 18 gage wires from the printed circuit board. (see pictorial #2)
• Replace the PCB by reversing the removal directions. The 18 gage wires that connect to the solenoids must be replaced in the proper order for the vacuum system to perform correctly.
How do I determine if a valve solenoid is defective before replacing it?
Before replacing any or all of the solenoids, you must first determine which if any solenoid is defective. You can determine if a solenoid is defective as follows:
• Disconnect the Pulse-Bac from the electrical power source.
• Remove the hood cover by removing the four 5/16″ X 10 X 3/4″ screws holding it to the base plate. (see pectoral #1)
• Disconnect the wiring to the power switch (sensor alarms, and alarm LED if equipped) by disconnecting the Molex connectors which connects the wiring to the base plate of the Pulse-Bac, before completely removing the hood.
• Locate the printed circuit board and the wiring for the solenoids. (see pictorial #2)
• You will need to use your volt ohm meter to determine which if any of the solenoids is defective. Set you VOM to ohms using a scale of 200 ohms or less. Be sure to zero your meter before taking your readings.
• Turn to page #20 of this manual for the location of test points on the printed circuit board.
• Connect your VOM negative test lead to the common point on the solenoid connection block on the printed circuit board marked ( SC ) or solenoid common.
• Connect your positive lead to points one, two and three individually on the solenoid connection block. Your VOM should read approximately 22 ohms at each test point if the solenoid is good and infinity or zero if the solenoid is bad. (see pictorial #2)
What are the specifications for the PB-1050, PB-1150, and PB-1250 models?
| Specifications | |
|---|---|
| Models | P1050, PB-1150, PB-1250 |
| Voltage | 120 Volts 50/60 Hz Single Phase all Models. |
| Filtration System | Patented Pulse-Bac® Technology |
| Current | PB-1050 12.1 | PB-1150 15.1 | PB-1250 15.5 |
| Filters | 3 ea. Twist-on/off 100% Spun Bond Polyester PTFE Coated, all Models. |
| Dimensions | PB-1050 23″ X 39″ X 21″ | PB-1150 23″ X 39″ X 21″ | PB-1250 23″ X 39″ X 21″ |
| Motor | See motor specification for each individual dust collector on page # 13 |
| Weight | PB-1050 79 lbs. | PB-1150 82 lbs. | PB-1250 82 lbs. |
| Performance | 1050; 140 CFM 89″ sealed lift. 1150; 170 CFM 110 ” sealed lift. 1250; 245 CFM 70″ sealed lift. |
| Storage Tank | 20 Gal. Tank, all Models. |
| Vacuum Port Inlet | 2″ inlet, all Models. |
| Casters | Non-Marking Five inch, all models. |
What is the Tank Capacity Sensor (TCS)?
CDCLarue revolutionary Tank Capacity Sensor ( TCS ) is available for installation on all 1000 series models. The sensor is an industry first as are a lot of the features found on CDCLarue products. TCS is available on all models as an option from the factory when you order your Pulse-Bac® or as an update at a later time. The TCS system senses when the tank is full and activates an audible and visual alarm to alert the operator, so to prevent the vacuum system from over filling the tank and damaging the filters. If not turn off in a timely manner after being fore warned, the TCS system will automatically shut off the vacuum motor.
What should I consider when operating a Pulse-Bac® for dust collection with other equipment?
When operating a Pulse-Bac Dust Recovery System with other equipment, you should take into account the following:
1. Make sure the equipment that you have chosen to operate with the dust collector is properly grounded with a third or fourth wire ground.
2. To ensure peak performance from your Pulse-Bac, check to see that the dust collector has the proper size and rating to support the equipment you intend to operate with it. If you are ok as to the proper model for the equipment you intend to operate with it, check with CDCLarue™ customer services.
3. Always connect the dust collector with the proper size of vacuum hose and extension Cord. Make sure you have the correct length and size of vacuum hose and electrical extension cord for the equipment you intend to use in conjunction with the Pulse-Bac.
4. Operating as a dust collector with a generator requires a minimum of 5K Watts to properly support the operation of any one of the PB-1000 series. When using a generator be sure to earth ground the generator to protect the Pulse-Bac electrical circuitry. Failure to earth ground the portable generator could cause major damage to your Pulse-Bac.
What does the image show regarding operating the PB-1050?
The pictorial shows a PB-1050 operating correctly with a seven inch surface grinder.
Who should perform repairs on the Pulse-Bac®?
With regular use the Pulse-Bac may require repair of critical components from time to time. This section of your manual will provide information for a qualified technician to make repairs to the machine when required. Most repairs to the machine can be made at your facility if the technician making the repairs is trained in electrical and mechanical theory. If you are not qualified to repair the vacuum you can contact CDCLarue™ Service department or have the unit returned to CDCLarue or one of CDCLarue authorized service centers for repair. If you or someone you know are qualified and need additional assistance in the repair of the machine, you can contact CDCLarue Service department and a qualified technician will help you to complete the repair.
CDCLarue recommends that any repairs made to the valve system in your Pulse-Bac either be made by CDCLarue or a technician that is qualified in the theory and repair of electro mechanical equipment.
What is the danger warning regarding servicing electro-mechanical equipment?
Danger: Attempting to repair any electro mechanical equipment without proper knowledge of the theory of electricity and mechanics can be detrimental to your health and well being and could cause death or major injuries. You should not attempt any of the following repairs without being qualified in electrical and mechanical repair theory.
What tools are needed for servicing the Pulse-Bac®?
If you or someone you have retained plan to make repairs on your Pulse-Bac you will need at a minimum the following tools and test equipment;
Volt ohm meter, digital or analog, Phillips screw driver #4 & #3, needle nose pliers, 5/16 ” nut driver, 3/8″ end wrench, and 1/8″ X 2″ slot screwdriver.
How do I replace the motor assembly?
To replace the motor assembly on a PB-1050, PB-1150, and PB-1250 follow the instruction below, each unit is similar in design, requiring little or no difference between units to remove the motor assembly and replace it with a new motor assembly. Motor assembly part numbers can be found on page # 13 and the assembly can be ordered from CDCLarue.
• Disconnect the Pulse-Bac from electrical power source.
• Loosen the hood cover by removing the four 5/16″ X 10 X 3/4″ screws holding it to the base plate. (see pectoral #1)
• Lift the hood and disconnect the wiring to the power switch (TCS alarm and alarm LED if equipped), by disconnecting the Molex connectors which connects the wiring to the main frame of the vacuum before completely removing the hood.
• Disconnect the wiring to the motor by unplugging the motor’s Molex power connector.
• Remove the three 3/8″ lock nuts and bolts securing the motor to the motor mount. Lift up on the motor to break the motor seal loose and remove the motor assembly.
• See parts replacements on page #13 to help in securing the proper motor assembly for your Pulse-Bac. Reverse the above instruction to mount the new motor.
What should I check if the unit will not start?
• Check for proper power source at the electrical outlet.
• Check cord cap for proper connection.
• Check to see that switch is in the on position and light is lit.
• Check internal 20 amp fuse.
What should I check if the unit’s CFM & Lift is low?
• Check to see if vacuum head is properly aligned on the tank and the seal is in good condition.
• Check to see if filters have become saturated with debris.
• Check to see if purging system is operating correctly.
• Check inlet hose for obstructions.
What should I check if the unit has dust coming out of the exhaust vents?
• Check to see if filters are tight and seals are in good condition.
• Check filters for tears or cuts.
• Check to see if filters are saturated.
• Check main fuse.
What should I check if the unit has no suction and the motors are not working?
• Check power to unit.
• Check power switch.
• Check motors.
• Contact CDCLarue™ for Service assistance at 1-918-216-6100
How do I position the optional Tank Capacity Sensor (TCS)?
Your new PB-1050, PB-1150, or PB-1250 may be equipped with CDCLarue™ exclusive TCS system, if not, you can order this option at anytime in the future as your machine is already equipped to accept the TCS feature at a later date. The TCS requires you to put it in its proper position prior to putting your Pulse-Bac® into service; this will insure proper operation of the Pulse-Bac.
Position the TCS as follows:
1. The TCS is shipped in the position shown in pictorial # 1.
2. Loosen the butterfly screw “A” and move the TCS rod to the upright position as shown in pictorial # 2.
3. Position the TCS rod at a 90° angle as shown in pictorial # 3.
4. Tighten the butterfly screw “A” to hold the TCS rod in place as shown in pictorial # 4. Do not over tighten the butterfly screw.
5. After the TCS rod is in place, the filters can be installed.
How does the Channel Timer circuit work (Overview)?
The Channel Timer circuit design supports several different operating modes. At the heart of the design is a microcontroller which handles all of the processing. Upon initial power-up, the microcontroller reads the settings for the Duration & Cycle Adjust Timers and determines if board supports 3 or 5 channels. Once this information is determined, the Cycle Timer begins its countdown, once it expires, Solenoid #1 is activated and the Duration Timer begins its countdown. Upon expiration of the Duration Timer, Solenoid #1 is deactivated. Prior to activating the next Solenoid, the microcontroller inserts a 5 second pause to allow the pressure in the tank to fully recover. Solenoid #2 is then activated for specified Duration, followed by another 5 second recovery period. This sequence repeats itself until the last Solenoid (either #3 or #5) has been activated, which completes the cycle. The Cycle Timer is then reloaded and the countdown begins once again.
How is the Solenoid ON duration determined (Fixed vs. Variable Duration)?
The ON duration of the Solenoids is either Fixed or Variable depending on the selected operating mode. The operating mode is determined by the R16. When R16 is installed, the unit operates in Variable Duration Mode, which has a range of 0.1 to 10 seconds (in 5 millisecond steps). When R16 is removed, the Duration is fixed.
How is the Cycle Duration determined?
The Cycle Duration has a range from 5 to 105 Seconds (in 200 millisecond steps). The actual time is determined by a potentiometer mounted on the board.
How is the 3ch vs. 5ch mode selected?
R14 determines whether the unit operates in 3ch or 5ch Mode. When R14 is installed, the unit operates in 5ch mode. When R14 is removed, the unit operates in 3ch mode.
How is the 110V vs. 220V operation configured?
Resistors R110A & B and R220 configure whether the unit operates with 110V or 220V input. For 110V operation, R110A & R110B should be installed (R220 must not be installed). For 220V operation, R220 should be installed (R110A & R110B must not be installed). These appropriate resistor configuration must be in the appropriate position prior to powering up the printed circuit board.
What is the 12Vdc Auxiliary Output used for?
The Auxiliary 12Vdc output will provide approximately 200ma@12Vdc.
How does the Sensor Support Circuit work?
The 12Vdc Auxiliary Output above may be used to power an external (sensor) circuit, which may in turn drive an on-board relay circuit. The terminal labeled “SOUT”, may be connect to the sensor’s output – this is actually an input (0 to 12Vdc), which is active high (input voltage from 3 to 12Vdc). The state of this input drives an output, RLY, which is a low side relay driver. This output can sink up to 200ma of current at 12Vdc.
What is the Spare Input/Output used for?
The board contains a spare I/O. At this time, there are no features associated with this provision. If needed, this line can be used as a digital input, digital output, or for an analog sensor.
How does the Tank Capacity Sensor (TCS) operate?
The PB-1050, PB-1150, or PB-1250 can be equipped with CDCLarue™ exclusive Tank Capacity Sensor (TCS). The TCS system is designed to prevent the vacuum from over filling the collection chamber and causing damage to the filters and vacuum motor components. Be sure to read and understand the instructions for setting up the TCS system when you receive your Pulse-Bac® instructions for positioning the TCS rod.
The Pulse-Bac is equipped with operational indicators on the front control panel and operates as follows;
1. When the TCS is installed on the Pulse-Bac, the front nameplate will be equipped with a red LED light indicator that when lit notifies the operator that the TCS has detected a full tank sounded an audible alarm and has turned the vacuum motor off. (see fig. 1)
2. The vacuum motor will not start unless the tank has been emptied or the sensor is cleared.
3. The audio alarm will continue to sound off until the sensor is cleared or power switch is turned off.
What is the warning regarding the TCS and restarting the motor?
Warning: Once the TCS has turned the vacuum motor off and signaled the operator with a visual and audio alarm, the vacuum motor may restart automatically when the vacuum head is removed from the tank. Always turn the Pulse-Bac power switch to the off position before removing the head to empty the tank after the TCS system has engaged. IF not done, the vacuum motor will restart, causing the operator to possible injury his or herself. Turning the power switch to the off position will silence the audible alarm and extinguish the visual alarm while ensuring the vacuum motor will not restart.
How do I change the filters?
Note: For best results, clean the bottom of the top filter receiver assembly after removing old filters and before replacing with new filters.
1. Remove the vacuum head from the collection tank and place it upside down on the floor or work bench.
2. Locate the filters, remove each filter by turning counter clockwise and pulling the filter straight up and away from the assembly.
3. Place a rubber o-ring and dust gasket on each new filter. Screw each filter on clockwise until snug, and then continue turning one quarter turn until filter is tightly fitted.
4. Place the vacuum head on top of the collection tank and secure it by latching it to the collection tank with the rubber latches. The Pulse-Bac® is now ready for service.
What is the warning regarding changing filters?
WARNING: For your safety, always turn off and disconnect the vacuum from the power source before replacing filters or performing any type of service.
What should I know about filter maintenance and replacement frequency?
Note: Filters should be changed out regularly to maintain peak performance. Do not use a filter with holes or tears, or missing o-rings. The filters are made of high quality Spun Bond Polyester media with a P.T.F.E coating, designed to stop particles as small as .1 micron, the filters should be used for dry pick-up only, and changed out regularly. CDCLarue recommends the filters be changed every four to six months or twice annually.
Filter Parts:
- FILTER RECEIVER, P/N 403234
- O-RING (1/8X6), P/N 401979
- FOAM RING, P/N 403242
- TWIST-ON FILTER, P/N 403236
What are the motor assembly part numbers for PB-1050, PB-1150, and PB-1250?
PB-1050 Motor Assembly:
PB-1150 Motor Assembly:
| ITEM | P/N | DESCRIPTION | QTY |
|---|---|---|---|
| 1 | 405460 | MOTOR, 120V, 2 STAGE TANGENTIAL | 1 |
| 2 | 405478 | MOTOR GASKET, 5.7″ DIAMETER | 1 |
PB-1250 Motor Assembly:
| ITEM | P/N | DESCRIPTION | QTY |
|---|---|---|---|
| 1 | 405461 | MOTOR, 120V, 2 STAGE TANGENTIAL BYPASS | 1 |
| 2 | 405478 | MOTOR GASKET, 5.7″ DIAMETER | 1 |
Other referenced parts:
- TOP COVER / HOOD ASSEMBLY
- DOLLY, MOTOR MOUNTING
- MOTOR MOUNTING BRACKET
What are the parts for the dolly assembly?
| ITEM | P/N | DESCRIPTION | QTY |
|---|---|---|---|
| 1 | 403862 | DOLLY, WIDE STANCE, RETROFIT | 1 |
| 2 | 405208 | CASTER, 5″ w/ LOCK [405046] | 1 |
| 3 | 405046 | CASTER, 5″ w/o LOCK | 4 |
| 4 | 405233 | NUT, #1/2-13, FLGD LCK | 5 |
| 5 | 405202 | BOLT, 1/2-13 X 1.25″, BLACK COATED | 5 |
How is the dolly assembled with casters?
ASSEMBLY PROCEDURE
1) INSTALL THE 1/2-13 X 1.25″ BOLT IN ONE OF THE ½” HOLES ON THE DOLLY; ALIGN THE 5″ CASTER (P/N 405046/405208) WITH THE BOLT AS SHOWN AND FASTEN THE BOLT WITH 1/2-13 FLANGE LOCK NUT AS SHOWN IN THE EXPLODED VIEW. REPEAT THE ABOVE FOR THE REMAINING 4 CASTERS.
CLICK HERE TO DOWNLOAD CDCLARUE PULSE-BAC PB-1250 (01) PDF MANUAL