FREE ENGLISH BLUETTI EP900 (01) PDF DOCUMENT.
FREE ENGLISH BLUETTI EP900 (01) PDF USER GUIDE.
FREE ENGLISH BLUETTI EP900 (01) PDF USER MANUAL.
FREE ENGLISH BLUETTI EP900 (01) PDF OWNER GUIDE.
FREE ENGLISH BLUETTI EP900 (01) PDF OWNER MANUAL.
FREE ENGLISH BLUETTI EP900 (01) PDF REFERENCE GUIDE.
FREE ENGLISH BLUETTI EP900 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH BLUETTI EP900 (01) PDF REFERENCE MANUAL.
FREE ENGLISH BLUETTI EP900 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH BLUETTI EP900 (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD BLUETTI EP900 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the main features of the BLUETTI EP900 EMS controller?
The BLUETTI EP900 EMS controller offers the following features:
• Control and monitor one or multiple inverters remotely from anywhere.
• Intelligently balance loads, optimize battery usage, and make the most of solar energy across multiple inverters.
• A touchscreen to operate in a visual manner.
What do the icons on the BLUETTI EP900 EMS controller interface mean?
| Icons | Description |
|---|---|
| Back arrow icon | Back to the previous page. |
| Home icon | Return to homepage. |
| Settings icon (gears) | Check and adjust system settings, like System Switch, Working Mode, Network Settings, Advanced Settings, etc. |
| Bell icon | Check the current alarm(s) and alarm history. |
| Downward checkmark icon | Go to the next page. |
| Left arrow icon | Flip backward. |
| Right arrow icon | Flip forward. |
How do I interpret the homepage of the BLUETTI EP900 EMS controller?
The homepage of the BLUETTI EP900 provides an overview of the system status:
1. Date & time: Displays the current date and time.
2. Connection Status: Shows icons for WiFi connection and Bluetooth connection.
3. Energy Flow: A visual representation of the Energy Storage System (ESS). This shows production, consumption, grid interaction, and battery state of charge.
4. Homepage Button: An icon to return to the homepage.
5. Settings: An icon to check and change system settings like System Switch, Working Mode, Network Settings, Advanced Settings, etc.
6. Alarms: An icon to check current alarm(s) and alarm history. The icon turns red in case of an alarm.
How can I understand the energy flow on the BLUETTI EP900?
The animation on the BLUETTI EP900 homepage gives you a simple way to understand how energy is flowing:
• SoC (State of Charge): The percentage shown in the central circle indicates the remaining battery level.
• PV generation: This icon shows how much power the ESS is drawing from your rooftop solar or solar panel(s). You can tap it to view more details.
• Grid charging or feeding: This icon shows how much power the ESS is drawing from or feeding back into the grid. You can tap it to view more details.
• Load consumption: This icon shows how much power is being supplied to your household appliances. You can tap to learn more about where the power is going.
How do I access and configure the basic settings on the BLUETTI EP900 EMS controller?
After connecting the device, tap the settings icon (gears) on the right side of the homepage to access the Setting page. From here, you can optimize your power usage by customizing various settings.
• System Switch: This is the main switch of the ESS. Keep it on if you want the ESS to charge and discharge. If it’s off, the system is in standby mode with no input or output. Note: If you’re connecting cables or not using the system, turn the System Switch off.
• Network Settings: Choose Bluetooth or WiFi for connecting your mobile device.
What are the configurable basic settings on the BLUETTI EP900?
The following basic settings can be configured on your BLUETTI EP900:
• Working Mode: Tap to set the working modes. Please refer to the specific working modes for details.
• Date and Time Settings: To set the date and time.
• Buzzer Switch: Enable to sound an alarm when the device encounters hardware faults.
• Proximity Sensor: The screen lights up as someone approaches when it’s enabled.
• Touch Sounds: Enable for a sound response during interface operation.
• Brightness: Slide to adjust the screen brightness.
• Auto Sleep: Choose screen sleep time (30s, 1min, 5min, always on). The default screen sleep time is 1 minute.
• Language: To select system language: English, German, or Japanese.
• Advanced Setting: To check and change more settings.
• Disaster Alert: With the switch on, the ESS switches to Backup Mode upon receiving a disaster alert and returns to the previous mode after the alert concludes.
What are the advanced settings on the BLUETTI EP900 EMS controller?
The advanced settings on the BLUETTI EP900 EMS controller include:
• Grid Self-adaption: Enable it when the ESS connects to an unstable grid with voltage fluctuations, low voltage, high voltage, etc. Once enabled, when charging from the grid, the charging power will gradually increase to minimize the impact on the grid.
• System Switch Recovery: To save the system switch status and restore it on restart.
• About Device: The information about the EMS controller.
• Reset: To reset all settings to default.
What working modes are available on the BLUETTI EP900 EMS controller and how do I select one?
The BLUETTI EP900 EMS controller allows configuration for three modes: Backup, Self-consumption, and Scheduled Charge & Discharge (Time of Use). To select a mode:
1. Tap Working Mode on the Setting page.
2. Tap Working Mode again.
3. Tap the left or right arrows to switch between the working modes.
4. Tap Confirm.
Note: To set parameters for the Time of Use mode, tap Confirm, and then tap the settings icon to adjust relevant parameters.
How does the Backup mode work on the BLUETTI EP900?
The Backup mode on the BLUETTI EP900 is suitable for areas with an unreliable power grid. In this mode, the system acts as a reliable backup power source that only activates when the grid fails. The ESS charges its batteries to full from both the grid and solar, giving priority to solar energy. With ample solar and grid energy, 100% of your energy is reserved for backup, ensuring uninterrupted power whenever needed.
How does the Self-consumption mode work on the BLUETTI EP900?
The Self-consumption mode on the BLUETTI EP900 is suitable for areas with abundant solar resources and a stable power grid. In this mode, the system prioritizes direct solar energy consumption for household needs. Any surplus energy is intelligently stored in the battery for peak hours or power outages.
How does the Time of Use mode work on the BLUETTI EP900?
The Time of Use mode on the BLUETTI EP900 is suitable for areas with fluctuating electricity prices. During peak electricity pricing, the ESS provides power to household appliances. During off-peak times when electricity rates are lowest, it draws power from the grid to charge the battery. In this mode, you can set an SoC High value and a specific charge/discharge schedule to optimize cost savings.
How do I set the SoC High and manage charge/discharge times in Time of Use mode on the BLUETTI EP900?
1. Set SoC High:
In the Time of Use settings, you can configure the SoC High value. The ESS will stop charging from the grid when the battery level reaches the configured SoC and will seamlessly switch to solar charging for the remaining capacity.
2. Manage Charge/Discharge Time:
a. Tap Scheduled Manage Charge/Discharge Time.
b. Tap OK in the Attention pop-up.
c. Specify a period, and set it as an Off-peak or Peak period.
• Off-Peak: Schedule the ESS to charge during off-peak hours when electricity costs are lower.
• Peak: Schedule the ESS to discharge during peak hours when electricity costs are higher.
• Middle: Disable the power supply from the battery to the load.
How can I charge the BLUETTI EP900 ESS via the grid?
You can charge your BLUETTI EP900 ESS from the grid using Scheduled Charging. Note: Disable the System Switch before setting working modes.
1. Tap Working Mode on the Setting page.
2. Tap Working Mode again.
3. Tap the left or right arrows to switch to the Time of Use mode, and tap Confirm.
4. Tap the settings icon to enter the parameters settings.
5. Tap Scheduled Manage Charge/Discharge Time.
6. Tap OK in the Attention pop-up.
7. Specify a period, and set it as an Off-Peak period.
Other options include using Backup mode or Custom mode (configured via the BLUETTI App).
How do I configure the BLUETTI EP900 to offset peak-hour energy usage using the EMS controller?
With this setup, you can offset your energy usage during peak hours but are unable to sell any extra energy back to the grid. To schedule the BLUETTI EP900 to charge during off-peak hours and supply power during peak hours:
1. Tap Working Mode on the Setting page.
2. Tap Working Mode again.
3. Tap the left or right arrows to switch to the Time of Use mode, and tap Confirm.
4. Tap the settings icon to enter the parameters interface.
5. Tap Scheduled Manage Charge/Discharge Time.
6. Tap OK in the Attention pop-up.
7. Choose a time period when electricity prices are lower. Set it as an Off-Peak period. And set Peak periods during times when electricity prices are higher.
How do I prioritize PV charging with the BLUETTI EP900?
This mode is suitable for areas with abundant solar resources. Switch on the PV switch of the inverter and check for a successful solar input. Turn on the System Switch on the Setting page; the system automatically prioritizes solar energy to supply the load and charge the battery.
If you want to rely less on the grid:
1. Tap Working Mode on the Setting page.
2. Tap Working Mode again.
3. Tap the left or right arrows to switch to the Self-consumption mode, and tap OK.
How do I set up the BLUETTI EP900 for backup power?
The BLUETTI EP900 ESS can be used as a backup power supply for emergencies, especially in areas with an unstable grid. To set it up:
1. Tap Working Mode on the Setting page.
2. Tap Working Mode again.
3. Tap the left or right arrows to switch to the Backup mode, and tap OK.
How is the firmware of the BLUETTI EP900 upgraded?
Upgrade the firmware of the BLUETTI EP900 solely through the BLUETTI App. Please refer to the product’s App user manual for details.
What is the Pro Mode on the BLUETTI EP900 EMS controller and what are its settings?
Pro Mode on the BLUETTI EP900 provides access to advanced system parameters. Note: Only authorized installers have permission to view and adjust parameters in this mode. The settings include:
| Item | Description |
|---|---|
| Charge From Grid | To enable the ESS to charge from the grid. • Single-phase Grid Max. Input Power: The maximum power that each phase of the ESS can draw from the grid or generator. • Single-phase Grid Max. Input Current: The maximum current that each phase of the ESS can draw from the grid or generator. |
| Feed Into Grid | To enable the ESS to feed into the grid. • Single-phase Grid Max. Discharge Power: The maximum power that each phase of the ESS can feed into the grid. • Single-phase Grid Max. Discharge Current: The maximum current that each phase of the ESS can feed into the grid. |
| Output Voltage | The output voltage of the ESS. |
| Output Frequency | The output frequency of the ESS (50Hz or 60Hz). |
| Battery Information | Tap to view battery information. |
| Automatic Transfer | Use the specified accessories provided by BLUETTI. Please refer to the ESS’s installation manual for details. |
| CT self-testing | Note: • Do not conduct the test under load, as it may affect the test results. • Conduct the test in grid-connected conditions. • Perform the test during the initial installation of the ESS; refer to the ESS’s installation manual for guidance. With this feature on, the system can detect and automatically adjust or prompt for any abnormal CT wiring. |
| Meter Switch | Enable to record micro-inverter parameters, including current, voltage, and power. |
| Meter Type | Select electric meter type. |
| Off-grid Parallel Switch | Activate to operate in off-grid parallel mode. |
| Inverter Switch | • Check inverter information. • Switch to other connected inverters. |
| Battery Information | Tap to view battery information. |
| Factory Reset | To factory reset all the settings. |
| AC/PV Meter Settings | Configure for AC-coupled solar devices. Note: Only connect one meter at a time, using the correct model and type to prevent system malfunctions. |
| Grid Meter Settings | Required to record information on grid power. |
CLICK HERE TO DOWNLOAD BLUETTI EP900 (01) PDF DOCUMENT