FREE ENGLISH BLUETTI EP900 (02) PDF DOCUMENT.
FREE ENGLISH BLUETTI EP900 (02) PDF USER GUIDE.
FREE ENGLISH BLUETTI EP900 (02) PDF USER MANUAL.
FREE ENGLISH BLUETTI EP900 (02) PDF OWNER GUIDE.
FREE ENGLISH BLUETTI EP900 (02) PDF OWNER MANUAL.
FREE ENGLISH BLUETTI EP900 (02) PDF REFERENCE GUIDE.
FREE ENGLISH BLUETTI EP900 (02) PDF INSTRUCTION GUIDE.
FREE ENGLISH BLUETTI EP900 (02) PDF REFERENCE MANUAL.
FREE ENGLISH BLUETTI EP900 (02) PDF INSTRUCTION MANUAL.
FREE ENGLISH BLUETTI EP900 (02) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD BLUETTI EP900 (02) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
How does the Automatic Start feature work on the BLUETTI EP900?
This feature is only for generators with power greater than 5000W, with 120V/240V, 60Hz, and not for 120V only.
Automatic Start: “Enable Generator” Mode in the BLUETTI app, the Generator automatically starts by receiving the signal through the DRMs/COM communication cable. Without grid power, Generator supplies power to the load and fully charges the system as if in Backup mode. When the grid is restored it switches back to grid power, the Generator stops running and the system supplies power to the loads.
Attention: Deactivate the Generator in the app when returning to grid power.
Note: Don’t forget to disable the “Enable Generator” Mode in the app when grid restored.
What are the pin definitions for the DRMs Port (Generator + Meter) on the BLUETTI EP900?
The following table details the pin definitions for the DRMs Port:
| PIN | Category | Definition | Specifications |
|---|---|---|---|
| 1 | GEN COM (Red) | Single-pole & double-throw relay common terminal | External DC input limit: 30VDC / 3A. (For generator input) |
| 2 | GEN NC (Black) | Single-pole & double-throw relay normally closed output | |
| 3 | GEN NO (Green) | Single-pole & double-throw relay normally open output | |
| 4 | INS GND (White) | Signal ground | / |
| 5 | 485-A3 (Yellow) | A: RS485 differential signal + | Connect to meter A2 |
| 6 | 485-B3 (Orange) | B: RS485 differential signal – | Connect to meter B2 |
Note: Pin 4, 5, and 6 are for communication with the electric meter. Refer to the meter’s user manual for wiring details.
What are the procedures for installing and configuring the BLUETTI EP900 for generator smart start?
Step 1: Wiring
Connect the cables according to the electrical diagrams. Note: Install a transfer-switch between the grid and the Generator.
Step 2: Power on
Press and hold the battery power button to activate the energy storage system. Refer to the product’s user manual and related materials for detailed instructions.
Step 3: Upgrade the firmware
Firstly, please upgrade the firmware on ARM and DSP to the latest version by bluetooth, ARM:502117, DSP:501913, IOT firmware V9043.14. If you do not know how to do, please read the APP user manual about how to upgrade the firmware.
Step 4: Configure Grid Input
Access the “Advanced Settings” page in the app and set the grid input limits. Be sure to set the power and current below 80% of the Generator’s rating. Refer to the product’s app user manual for details.
Step 5: Enable Generator
Access the “Advanced Settings” page in the app and turn on the “Enable Generator” Mode. Refer to the product’s app user manual for detailed instructions.
How do I enable or disable the Pro mode for the generator on the BLUETTI EP900?
After entering the detailed settings page of the generator, two environments can be selected to control the ignition of the generator:
1. Do not enable Pro mode
Turn off the “Pro mode” switch (SOC and time period control parameters no longer take effect), and only the “Generator Enable” can control whether to ignite (turn on → ignite; turn off → stall).
2. Enable Pro mode
Turn on the ‘Generator Enable’ switch, activate the ‘Pro mode’ switch, set SOC and time period control to intelligently control the ignition timing of the generator.
Attention: “Generator Enable” is the main switch. When turned off, the oil engine will shut down; In the open state, prioritize whether to ignite according to the settings parameters of the Pro mode.
In Pro mode, ‘time period control’ has a higher priority than ‘SOC’. Up to 3 time periods can be set, and the switch on the right side of each time period controls whether the ignition occurs during that time period (on → ignition during time period; off → shutdown during time period).
In Pro mode, if the current time is outside the set time period, the ignition is determined by the upper and lower limits of SOC. For example, between 15:00 and 16:00, if the SOC of the battery is ≤ 20%, the oil engine will ignite; On the contrary, if the SOC of the battery is ≥ 80%, the engine will shut down. (Assuming that the ignition of the fuel engine is triggered when SOC ≤ 20%, and the fuel engine remains in the ignition state until SOC reaches 80% without being interrupted by the time period).
How do I initiate the generator with the BLUETTI EP900?
Turn on the “System Switch” to enable the Generator via the app.
NOTE:
The Generator application cannot be enabled at the same time as the AC coupling application/micro-inversion application.