Free English AQQA AQ150 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD AQQA AQ150 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the safety warnings for operating the AQQA AQ150 External Filter?
1. Never pull the power cord with wet hands.
2. Ensure the power supply voltage and frequency align with those specified on the product label.
3. Cut off the power immediately at the first sign of abnormality. Disconnect all power before performing any maintenance.
4. Refrain from placing aquariums and filters near household electronics like computers and TVs.
5. Regularly unplug the power cord to remove accumulated dust and grime for safety.
6. Avoid pinning or binding the power cord and altering or replacing switches. If the power cord is damaged, dispose of the product.
7. To keep the plug and socket dry, position the socket between 1.3 to 1.5 meters above the ground and safeguard the power cord. (A “U” shape placement is recommended).
8. Do not use extension cords to minimize the risk of electric shock from water overflow or leakage.
9. Keep the filter away from flammable materials like gasoline.
10. Exercise caution to prevent children from interfering with the filter.
What important points should I be aware of when using the AQQA AQ150 External Filter?
1. The filter must be installed at least 10 cm above the water level.
2. This product is equipped with a protection device to prevent motor overheating. The motor will stop running if it overheats due to empty running or debris blocking the water blades. The motor will resume operation once debris is removed and overheating is resolved. Please check for the following causes of overheating: reduced flow, kinked hoses, blocked water blades, etc.
3. Before use, double-check that the connecting hoses are correctly attached, and observe the operation for a while to ensure it runs smoothly.
4. This filter is designed exclusively for indoor ornamental fish tanks and should not be used for other purposes.
5. Do not lay the filter body on its side. Overly compact placement of filter media may decrease water flow.
6. Use the shortest and highest-quality hoses to minimize water resistance.
7. Regularly clean all components and replace filter media and other consumables to extend the motor’s lifespan.
8. Be vigilant as small fish may be sucked into the filter.
9. Do not use the product when frozen, as it may damage it.
10. Avoid running the product without water for extended periods, as it can cause permanent damage.
What are the product specifications for the AQQA AQ150 models?
| Model | Volt/Freq | Power | Max flow | Product size | Applicable tank size | Cord length |
|---|---|---|---|---|---|---|
| AQ150-1200L | US Standard: AC100-120V/50-60Hz | 18W | 1200L/H (317GPH) | 7.1″x7.1″x11.2″ (18x18x29CM) | 16″-31.5″ (40-80cm) | 6.2ft (1.9m) |
| AQ150-1800L | UK/AU Standard: AC 220-240V/50Hz | 25W | 800L/H (475GPH) | 7.1″x7.1″x16″ (18x18x40CM) | 20″-39.5″ (50-100cm) | 6.2ft (1.9m) |
| AQ150-2200L | UK/AU Standard: AC 220-240V/50Hz | 35W | 2200L/H (581GPH) | 8.5″x8.5″x18.5″ (21x21x47cm) | 28″-55″ (70-140cm) | 6.2ft (1.9m) |
What spare parts come with the AQQA AQ150 External Filter?
The spare parts include:
Double switch
Inlet Hose
Outlet hose
Exhaust valve
Nut
Connection pipe
Motor
Sealing ring
Nozzle for elbow pipe
Sand separator screen
Front Case (Quartz balls and filter cotton)
Extension Pipe
Elbow pipe
Plug
Pressure clasp
Suction cup clip
Shower pipe
Filter canister
Connection pipe
Basket strainer (surface oil film skimmer)
Additionally, the quantity of filter media varies by model:
AQ150-1200L: 1*Quartz balls and filter cotton
AQ150-1800L: 3*Quartz balls and filter cotton
AQ150-2200L: 3*Quartz balls and filter cotton
How do I open the AQQA AQ150 filter canister?
1. Release the safety latch by pulling it up from the bottom.
2. Unlock all the pressure clasps.
3. Hold the handles on both sides and lift them, ensuring to press down on the filter tank body during removal.
How do I clean the filter media in the AQQA AQ150?
1. Remove the filter media separation screen, filter screen, and filter media from the filter canister for cleaning.
2. Clean all the filter media thoroughly.
How do I reassemble the filter basket in the AQQA AQ150 canister?
1. Insert the filter basket into the filter canister.
2. Make sure the red wire channel is correctly aligned with the corresponding clips on the canister’s base.
How do I install the top motor on the AQQA AQ150 filter canister?
Mount the motor into the filter canister, ensuring the motor’s water intake aligns properly with the filter basket’s opening. Next, firmly press down on the motor and lock it in place with the pressure clasps.
How do I install and operate the switch on the AQQA AQ150 External Filter?
Position the switch lever to the lowest water outlet setting (minimum water flow). Insert the switch into the two corresponding holes on the motor, and firmly press down on the lever to lock the switch in place on the motor’s top. After that, adjust the water flow to the maximum. Note: ① indicates the switch lever, and ② indicates the water flow control valve.
How do I connect the hoses to the AQQA AQ150 External Filter?
1. Attach the other end of the IN hose to the water intake elbow, extension pipe, basket strainer (surface oil film skimmer), and any additional fittings required.
2. Attach the other end of the OUT hose to the outlet elbow and the shower pipe.
How do I prime the AQQA AQ150 External Filter and check for leaks?
Press the button 3 to 6 times to allow water to naturally fill the filter canister to the top.
1. After the filter canister is filled with water, it will automatically release any trapped air, enabling it to operate efficiently.
2. Check all connection points for any signs of leakage.
3. In the event of leaks, switch off the power supply and tighten the affected connections to resolve the issue.
What types of filter media are recommended for the AQQA AQ150 and what are their functions?
Note: Some media need to be purchased separately.
1. White Filter Sponge: Effectively traps fine particulates. Suggested replacement: Monthly.
2. Filter Sponge: Fosters nitrifying bacteria, decomposes waste, and filters debris. Suggested replacement: Every six months.
3. Ceramic Rings: Improves water circulation, boost filtration performance, and remove larger particles.
4. Bio Balls: Promotes nitrifying bacteria growth, biological and physical breakdown, and filtration.
5. Activated Carbon: Eliminates odors and clarifies water. Suggested replacement: Monthly.
What should I do if the motor on my AQQA AQ150 fails to fit onto the filter canister?
| Reason | Solution |
|---|---|
| The sand separator screen is positioned incorrectly. | Position the sand separator screen correctly. |
| Sand separator screens are positioned incorrectly between each other. | Correctly align the sand separator screens. |
| The arrangement of filter media is either too dense or excessive. | Remove excess filter media. |
What should I do if the motor on my AQQA AQ150 is leaking?
| Reason | Solution |
|---|---|
| The pressure clasp is not secured correctly. | Tighten the pressure clasp. |
| Debris is present on the sealing ring. | Clear any debris from the sealing ring. |
| The sealing ring is damaged. | Replace the damaged sealing ring. |
Why is the impeller on my AQQA AQ150 not working and what is the solution?
| Reason | Solution |
|---|---|
| The power is not plugged in. | Plug in the power. |
| The shaft has snapped. | Replace the shaft. |
| The shaft or impeller is obstructed by debris. | Remove foreign objects. |
What causes decreased water flow in the AQQA AQ150 and how do I resolve it?
| Reason | Solution |
|---|---|
| Debris is obstructing the switch. | Remove foreign objects. |
| The hose is bent. | Straighten the hose. |
| The filter media has debris. | Clean the filter media to remove debris. |
| The basket strainer is clogged. | Remove the blockage from the basket strainer. |
Why is there air buildup in my AQQA AQ150 filter canister and how can I fix it?
| Reason | Solution |
|---|---|
| Incorrect positioning of the device above the water level. | Adjust the device so that the motor is more than 3.9 inches (10 cm) below the water surface, maintaining a suitable distance. |
| Filter media is debris-laden. | Clean the filter media. |
| Air intrusion in the water inlet hose. | Inspect the water inlet hose for sealing issues. |
What should I do if the water flow is impeded after automatic suction on my AQQA AQ150?
| Reason | Solution |
|---|---|
| The water inlet hose is improperly installed. | Properly reinstall the water inlet hose. |
| The device is too close to the water surface. | Position the motor more than 10 cm below the water level, adjusting the distance if necessary, maintaining a suitable distance. |
| Water is retained within the bucket, hoses, or other components. | Remove the retained water. |
What causes noise generation during the operation of the AQQA AQ150 and how can I fix it?
| Reason | Solution |
|---|---|
| Air in the hoses. | Gently sway the body from side to side to release the trapped air. |
| Air trapped within the canister. | While the filter is powered on, move it left and right to expel the air. |
| Motor is above the water surface. | Ensure the motor is positioned more than 10 cm below the water surface. |
| Air is retained in the filter body. | Cycle the power supply on and off 4-5 times, and sway the filter body. |
| Debris on the rotor. | Remove the debris. |
| Shaft is snapped. | Replace the shaft. |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD AQQA AQ150 (01) PDF DOCUMENT